Wulffsalomonsen2922

Z Iurium Wiki

±0.089) mm. There was no statistical difference between the feature points 5-5', while there were statistical differences between the other feature points. CONCLUSION By the dental articulator position method, the model scanner reproduces the occlusal contact point with high sensitivity and PPV, and that meets clinical needs. Meanwhile, the distance between the feature points is greater than the reference value, which will lead to occlusal disturbance, and require clinical grinding.OBJECTIVE To provide a reference for using intraoral scanners for making clinical diagnostic dentures of edentulous jaws by comparing the accuracy of three intraoral scanners for primary impression and jaw relation record of edentulous jaws. METHODS This study contained 6 primary impressions of the edentulous patients. Each of the impressions consisted of the maxillary primary impression, the mandibular primary impression and the jaw relation record. For each of them, a dental cast scanner (Dentscan Y500) was used to obtain stereolithography (STL) data as reference scan, and then three intraoral scanners including i500, Trios 3 and CEREC Primescan were used for three times to obtain STL data as experiment groups. In Geomagic Studio 2013 software, trueness was obtained by comparing experiment groups with the reference scan, and the precision was obtained from intragroup comparisons. Registered maxillary data of the intraoral scan with reference scan, the morphological error of jaw relation record was obtained (0.62±0.18) mm, and (0.53±0.53) mm for anterior and posterior directions; (0.95±0.59) mm, (0.69±0.45) mm, and (0.60±0.22) mm for left and right directions. The displacement of the jaw position of the three scanners in vertical dimension, anterior and posterior directions and the left and right directions were within the 95% consistency limit. CONCLUSION Three intraoral scanners showed good trueness and precision. The i500 and Trios 3 scanners had more errors in jaw relation record, but they were used as primary jaw relation record. It is suggested that three intraoral scanners can be used for obtaining digital data to make diagnostic dentures and individual trays, reducing possible deforming or crack when sending impressions from clinic to laboratory.OBJECTIVE To analyze the relationship between the width of the maxillary anterior teeth and the anterior arch perimeter, to analyze the change rule of the width of the anterior teeth and the anterior arch perimeter, when altered the convexity of the anterior arch, with the width of the maxillary anterior arch keeping constant, and to provide a reliable basis for later digitized and personalized aesthetic analysis of front teeth. METHODS In the study, 61 front teeth complete and well-arranged models had been selected from the working models after the prostheses in Department of Prosthodontics, Peking University School and Hospital of Stomatology, including 22 male models and 39 female models. A photograph was taken from the occlusal surface of each model using the fixed magnification with a single lens reflex camera. The width of anterior teeth, the width of anterior arch and the convexity of anterior arch had been measured using the Photoshop software. The ratio of the width of the anterior teeth to the widthn the range of 5 mm and the width of anterior teeth or the front arch circumference. With each increase or decrease of 1 mm of the convexity of anterior arch, the width of the middle incisor increased or decreased by about 0.18 mm, the half circumference of the anterior arch increased or decreased by about 0.50 mm. CONCLUSION The width of the anterior teeth in the middle-distal direction remained stable in the anterior arch circumference. Within a certain range, when the width of the maxillary anterior arch remains unchanged, the width of the anterior teeth and the perimeter of the anterior teeth are positively correlated to the convexity of the anterior arch.OBJECTIVE To investigate the feasibility and accuracy of using digital technology to design anterolateral thigh flap (ALTF) in oral and maxillofacial defect reconstruction. METHODS Ten cases underwent oral and maxillofacial defects reconstruction with ALTFs in Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology from June 2019 to Oct. 2019 were enrolled. There were 7 males and 3 females with the mean age of 47.1 years. Preoperative high frequency color Doppler ultrasound examination was performed to detect the perforators of ALTF. CT data of the thigh was imported in DICOM (digital imaging and communications in medicine) format to the Proplan CMF 3.0 software (Materalise, Belgium), then virtual harvest of ALTF was performed according to the points of perforators detected by high frequency color Doppler ultrasound and the virtual flap volume was calculated by Proplan CMF 3.0 software. ALTF was harvested followed by preoperative virtual design, and the actual flap v2.5 cm³). There was no significant difference between the virtual flap volume measured by Propaln CMF 3.0 software and the actual volume measured by draining method (t=0.318; P=0.758). CONCLUSION Preoperative virtual design of ALTF has good feasibility and accuracy and can be used to guide the harvest of ALTF during operation.OBJECTIVE To investigate the effect of preoperative condylar condition for mandible retrognathism deformities with severe temporomandibular joint osteoarthrosis on the stability of the jaw after orthognathic surgery and on the postoperative condylar volume changes. METHODS In this retrospective study, from 2014 to 2019, 37 patients including 1 male and 36 female, aged between 21 to 34 years old with an average age of (28.03±6.52) years, were diagnosed with mandible retrognathism deformities with severe temporomandibular joint osteoarthrosis by Peking University School and Hospital of Stomatology and received orthognathic surgery, meeting the inclusion criteria were included. Vardenafil According to the preoperative condylar condition. There were divided into smooth group and non-smooth group, the lateral cephalometric films 1 week (T0), 3 months (T1), 6 months (T2) and 1 year (T3) after surgery were used to establish the coordinate system and cephalometric analysis to determine the stability of the jaw after operation. The three-dimensional model of the condyle was segmented by cone beam computed tomography (CBCT) 1 week (T0), 3 months (T1), 6 months (T2) and 1 year (T3) after surgery and the volume was obtained to evaluate the change of the condyle volume after surgery.

Autoři článku: Wulffsalomonsen2922 (Purcell Brandon)