Washingtonforbes7416
This analysis leads to the evaluation of time-dependent cell photoactivity and qualitative information on metal speciation/bioavailability in solution. Biosensor performance and the position, shape, number, and magnitude of detected peaks are discussed in relation to the metabolic pathways operative during the successive light emission modes identified here over time. Altogether, the results clarify the contributions of metal/nutrient bio-availabilities and food quality to cell response typology.The combination of the new perturbed spiral channel and a slanted gold interfingered transducer (IDT) is designed to achieve precise dynamic separation of target particles (20 μm). The offset micropillar array solves the defect that the high-width flow (avoiding the occurrence of channel blockage) channel cannot realize the focusing of small particles (5 μm, 10 μm). The relationship between the maximum design gap of the micropillar (Smax) and the particle radius (a) is given Smax = 4a, which not only ensures that small particles will not pass through the micropillar gap, but also is compatible with the appropriate flow rates. A non-offset micropillar array was used to remove 20 μm particles in the corner area. The innovation of a spiral channel structure greatly improves the separation efficiency and purity of the separation chip. The separation chip designed by us achieves deflection separation of 20 μm particles at 24.95-41.58 MHz (κ = 1.09-1.81), at a flow rate of 1.2 mL per hour. When f = 33.7 MHz (κ = 1.47), the transverse migration distance of 20 μm particles is the smallest, and the separation purity and efficiency are as high as 92% and 100%, respectively.A novel electrochemical sensor designed to recognize and detect tartrazine (TZ) was constructed based on a molecularly imprinted polydopamine (MIPDA)-coated nanocomposite of platinum cobalt (PtCo) nanoalloy-functionalized graphene oxide (GO). The nanocomposites were characterized and the TZ electrochemical detection performance of the sensor and various reference electrodes was investigated. Interestingly, the synergistic effect of the strong electrocatalytic activity of the PtCo nanoalloy-decorated GO and the high TZ recognition ability of the imprinted cavities of the MIPDA coating resulted in a large and specific response to TZ. Under the optimized conditions, the sensor displayed linear response ranges of 0.003-0.180 and 0.180-3.950 µM, and its detection limit was 1.1 nM (S/N = 3). The electrochemical sensor displayed high anti-interference ability, good stability, and adequate reproducibility, and was successfully used to detect TZ in spiked food samples. Comparison of important indexes of this sensor with those of previous electrochemical sensors for TZ revealed that this sensor showed improved performance. This surface-imprinted sensor provides an ultrasensitive, highly specific, effective, and low-cost method for TZ determination in foodstuffs.In this study, an "all-in-one" digital microfluidics (DMF) system was developed for automatic and rapid molecular diagnosis and integrated with magnetic bead-based nucleic acid extraction, loop-mediated isothermal amplification (LAMP), and real-time optical signal monitoring. First, we performed on- and off-chip comparison experiments for the magnetic bead nucleic acid extraction module and LAMP amplification function. The extraction efficiency for the on-chip test was comparable to that of conventional off-chip methods. The processing time for the automatic on-chip workflow was only 23 min, which was less than that of the conventional methods of 28 min 45 s. Meanwhile, the number of samples used in on-chip experiments was significantly smaller than that used in off-chip experiments; only 5 µL of E. coli samples was required for nucleic acid extraction, and 1 µL of the nucleic acid template was needed for the amplification reaction. In addition, we selected SARS-CoV-2 nucleic acid reference materials for the nucleic acid detection experiment, demonstrating a limit of detection of 10 copies/µL. The proposed "all-in-one" DMF system provides an on-site "sample to answer" time of approximately 60 min, which can be a powerful tool for point-of-care molecular diagnostics.Nowadays, self-powered wearable biosensors that are based on triboelectric nanogenerators (TENGs) are playing an important role in the continuous efforts towards the miniaturization, energy saving, and intelligence of healthcare devices and Internets of Things (IoTs). In this review, we cover the remarkable developments in TENG-based biosensors developed from various polymer materials and their functionalities, with a focus on wearable and implantable self-powered sensors for health monitoring and therapeutic devices. The functions of TENGs as power sources for third-party biosensors are also discussed, and their applications in a number of related fields are concisely illustrated. Finally, we conclude the review with a discussion of the challenges and problems of leveraging TENG-based intelligent biosensors.Humans have searched far beyond our planet to understand the fundamental principles and mechanisms of life [...].Suspended particles play a vital role in aquatic environments. We propose a method to rapidly measure the scattered polarization parameters of individual suspended particles with continuously large angular range (PCLAR), from 60° to 120° in one shot. A conceptual setup is built to measure PCLAR with 20 kHz; to verify the setup, 10 μm-diameter silica microspheres suspended in water, whose PCLAR are consistent with those simulated by Mie theory, are measured. PCLAR of 6 categories of particles are measured, which enables high-accuracy classification with the help of a convolutional neural network algorithm. PCLAR of different mixtures of Cyclotella stelligera and silica microspheres are measured to successfully identify particulate components. Furthermore, classification ability comparisons of different angular-selection strategies show that PCLAR enables the best classification beyond the single angle, discrete angles and small-ranged angles. Simulated PCLAR of particles with different size, refractive index, and structure show explicit discriminations between them. Inversely, the measured PCLAR are able to estimate the effective size and refractive index of individual Cyclotella cells. Results demonstrate the method's power, which intrinsically takes the advantage of the optical polarization and the angular coverage. Future prototypes based on this concept would be a promising biosensor for particles in environmental monitoring.In recent years, many efforts have been made to develop rapid, sensitive and user-friendly glucose biosensors for monitoring blood glucose concentration in patients. In this study, the electrochemical glucose biosensors based on graphite rod (GR) electrode electrochemically modified with dendritic gold nanostructures (DGNs) and glucose oxidase (GOx) were developed. Phenazine methosulfate was used as a soluble redox mediator. Three GOx immobilization methods adsorption on DGNs and cross-linking with glutaraldehyde (GA) vapour (GA-GOx/DGNs/GR), covalent immobilization on DGNs modified with 11-mercaptoundecanoic acid self-assembled monolayer (SAM) (GOx-SAM/DGNs/GR) and covalent immobilization on SAM with additional cross-linking with GA vapour (GA-GOx-SAM/DGNs/GR), were used. It was determined that GA significantly improved the stability of the enzyme layer. The difference of maximal current generated during the enzymatic reaction (ΔImax) equal to 272.06 ± 8.69 µA was obtained using a biosensor based on GA-GOx/DGNs/GR electrodes. However, the highest ΔImax equal to 384.20 ± 16.06 µA was obtained using GA-GOx-SAM/DGNs/GR electrode. ΔImax for biosensors based on the GA-GOx-SAM/DGNs/GR electrode was 1.41 times higher than for the GA-GOx/DGNs/GR, whereas the linear dynamic range from 0.1 to 10 mM was the same using all three GOx immobilization methods. OSMI-1 The limit of detection using GA-GOx-SAM/DGNs/GR and GA-GOx/DGNs/GR electrodes was 0.019 and 0.022 mM, respectively. The ability to detect glucose in the serum by developed biosensors was evaluated.Although phosphate (Pi) is a necessary nutrient for the growth of aquatic organisms, the presence of excess Pi leads to water eutrophication; thus, it is necessary to accurately determine the content of Pi in water. A method for the determination of trace Pi in aquaculture water was developed based on surface-enhanced Raman spectroscopy (SERS) combined with rhodamine 6G (R6G)-modified silver nanoparticles (AgNPs) as the active substrate. The adsorption of R6G on the AgNP surfaces led to a strong SERS signal. However, in the presence of Pi and ammonium molybdate, phosphomolybdic acid formed, which further associated with R6G to form a stable R6G-PMo12O403- association complex, thereby hindering the adsorption of R6G on the AgNPs, and reducing the SERS intensity; this sequence formed the basis of Pi detection. The decrease in the SERS intensity was linear with respect to the Pi concentration (0.2-20 μM), and the limit of detection was 29.3 nM. Upon the application of this method to the determination of Pi in aquaculture water, a recovery of 94.4-107.2% was obtained (RSD 1.77-6.18%). This study provides an accurate, rapid, and sensitive method for the trace determination of Pi in aquaculture water, which is suitable for on-site detection.In recent years, the application of cell-free protein synthesis systems in biosensing has been developing rapidly. Cell-free synthetic biology, with its advantages of high biosafety, fast material transport, and high sensitivity, has overcome many defects of cell-based biosensors and provided an abiotic substitute for biosensors. In addition, the application of freeze-drying technology has improved the stability of such systems, making it possible to realize point-of-care application of field detection and broadening the application prospects of cell-free biosensors. However, despite these advancements, challenges such as the risk of sample interference due to the lack of physical barriers, maintenance of activity during storage, and poor robustness still need to be addressed before the full potential of cell-free biosensors can be realized on a larger scale. In this review, current strategies and research results for improving the performance of cell-free biosensors are summarized, including a comprehensive discussion of the existing challenges, future trends, and potential investments needed for improvement.We explored the feasibility of developing immunoassay technology with a linear carrier, to develop a simpler and cheaper rapid immunoassay technology. We selected aflatoxins as an example for research, as they are a group of highly toxic and carcinogenic compounds representing a worldwide threat to human health and life. With a non-competitive immunoassay, we detected and evaluated the effect of 28 different linear materials on antibody immobilization. Mercerized cotton and Dyneema line were chosen from the linear materials for further comparison using a competitive immunoassay, because both showed high-signal values and relatively low background noise. The results showed the sensitive IC50 of mercerized cotton as the reaction carrier was 0.33 ng/mL, and the linear range was 0.16~3.25 ng/mL. The sensitivity using Dyneema line as the reaction carrier was 1.16 ng/mL. The competitive curves of four sample matrices were established to evaluate the stability of the detection system; these were basically consistent with those without sample matrices.