Vargasmcconnell7733
Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in heart failure patients. The purpose of this study was to assess the value of gated myocardial perfusion single-photon emission computed tomography (GMPS) phase analysis for predicting survival in heart failure patients undergoing CRT.
This retrospective cohort study evaluated heart failure patients who underwent GMPS prior to CRT. Phase histogram bandwidth (PHB) and phase SD (PSD) were calculated using GMPS data. Cox proportional hazards model was used to identify independent predictors of overall survival (OS).
A total of 35 patients (age 65.1 ± 13.3, 27 men and 8 women), who were followed for mean of 4.1 ± 2.9 years, were enrolled in the study. PSD of greater than 45° was found to be an independent predictor of poor OS (hazard ratio = 12.63, P = 0.011) when compared with age (hazard ratio = 1.00, P = 0.922), gender (hazard ratio = 0.31, P = 0.155), NYHA class (hazard ratio = 0.45, P = 0.087), QRS duration greater than 150 ms (hazard ratio = 2.38, P = 0.401), pre-CRT left ventricular ejection fraction (LVEF) (hazard ratio = 0.95, P = 0.175) and etiology of heart failure (hazard ratio = 1.42, P = 0.641). Foretinib clinical trial Furthermore, PHB greater than 140° was also found to be an independent predictor of poor OS (hazard ratio = 5.63, P = 0.040) when compared with age, gender, NYHA class, QRS duration greater than 150 ms, pre-CRT LVEF and etiology of heart failure.
PSD and PHB, measured by GMPS, may serve as biomarkers for the prediction of survival in patients undergoing CRT.
PSD and PHB, measured by GMPS, may serve as biomarkers for the prediction of survival in patients undergoing CRT.
Myocardial perfusion imaging (MPI) by gated single-photon emission computed tomography (SPECT) is a feasible method in the evaluation of left ventricular perfusion and function. The purpose of this study was to determine the threshold and grading of left ventricular (LV) diastolic dysfunction (LVDD) using gated SPECT MPI.
A total of 149 patients were recruited in the study. All of the patients underwent a standard 2-day stress/rest gated MPI study and transthoracic echocardiography within 2 weeks. The reconstructed rest-only images were analyzed by Cedar-Sinai's quantitative gated SPECT and the LV diastolic parameters, including peak filling rate (PFR), time to PFR (TTPF) and secondary PFR (PFR2) to PFR ratio were provided and compared to echocardiographic data.
68 (45.6%) and 81 (54.4%) of patients were categorized in LVDD-absent and LVDD-present groups on the basis of LVDD evidence in echocardiography, respectively. receiver-operating-characteristic analysis for PFR and TTPF was performed, resulting in diagnostic sensitivities of 70 and 57% and specificities of 60 and 75% for PFR <2.6 end-diastolic volumes (EDV)/s and TTPF>160.5 ms, respectively. Applying our previously used thresholds of <1.70 EDV/s for PFR, >208 ms for TTPF and >1 for PFR2/PFR, sensitivities and specificities of 9.9 and 96.6%, 9.9 and 95.6% and 13.8 and 88% were resulted, respectively. Grading of LVDD on the basis of MPI-obtained diastolic parameters showed considerable overlapping data by interquartile range.
Gated SPECT MPI can be used as a highly specific means for detection of LV diastolic dysfunction when compared to echocardiography. However, grading of severity of diastolic heart failure appears to be impracticable.
Gated SPECT MPI can be used as a highly specific means for detection of LV diastolic dysfunction when compared to echocardiography. However, grading of severity of diastolic heart failure appears to be impracticable.
68Ga-PSMA-PET/CT is a relatively new technique, that is rapidly becoming widespread. We aimed to contribute interobserver-intraobserver agreement of 68Ga-PSMA-PET/CT, among low/high-experienced interpreters.
68Ga-PSMA-PET/CT of 56 patients with prostate cancer were evaluated blindly by four observers. Visual interpretation of malignant disease and SUVmax for lymph node (LN) regions, local tumor, bones and visceral organs were recorded. Cohen's Kappa and Fleiss' Kappa analyses were used to measure agreement between low/high/all-experienced observers. Variations were compared for regions, and the effect of prostate-specific antigen or Gleason score on the results was investigated.
Interobserver agreement was almost perfect for all LN regions (LN1 low-experienced κ 0.84/0.84, high-experienced 0.89/0.96; LN2 low-experienced κ 0.88/0.79, high-experienced 0.95/0.95; LN3 low-experienced κ 0.84/0.89, high-experienced 0.87/0.94, first/second readings, respectively) and bone lesions (low-experienced κ 0.88/0.88, t although a reader may be familiar with other PET agents, a more consistent interpretation of 68Ga-PSMA-PET/CT requires training with a small number of identified cases.
Interpretation of prostate-specific membrane antigen (PSMA) for prostate cancer is acceptably consistent among observers, but some details are noteworthy. The evaluation should be done more algorithmically for local tumors, since all observers showed relatively lower agreement. The agreement increased as prostate-specific antigen and Gleason score increased. The observer with PSMA experience less then 30 readings showed lower reliability, distinct from the others. This indicates that although a reader may be familiar with other PET agents, a more consistent interpretation of 68Ga-PSMA-PET/CT requires training with a small number of identified cases.
This study aimed to evaluate the distribution of Astatine-211 (211At) solution dispersion in a small animal cage using autoradiography imaging to simulate the dispersion of 211At in a lab room to eventually prevent user's risk of internal exposure in terms of radiation safety.
211At radiation sources with two chemical properties (Na211At and Free 211At) were prepared. The solutions of 211At were placed onto a dish with paper, and then, it was placed in a small animal cage for 3 h. After removing the dish, an imaging plate with attaching reference sources was placed at four walls of the cage for 15 h in a lead box. Imaging plates were read, and all pixel data were calculated using Microsoft Excel 2016 to obtain three-dimensional (3D) distribution. Calculated results were depicted using a 3D sphere model.
The mean activity of Free 211At was 2.3 times higher than that of Na211At on all autoradiography images. In the cage, the shape of the dispersion of Na211At was almost homogeneous, whereas that of Free 211At was more heterogeneous.
We found that the solution of 211At vaporized naturally and was distributed heterogeneously in the cage, and the chemical properties of 211At influenced their behaviors. These results must be considered to minimize the risks of radiation safety.
We found that the solution of 211At vaporized naturally and was distributed heterogeneously in the cage, and the chemical properties of 211At influenced their behaviors. These results must be considered to minimize the risks of radiation safety.
The purposes of this study are to (1) identify patterns of inpatient PET/computed tomography (CT) use in and outside of the USA and (2) characterize inpatient PET/CT use by location and indication.
The study was deemed exempt by the Institutional Review Board. A survey link through REDCap was emailed to the Society of Nuclear Medicine and Molecular Imaging (SNMMI) members and PET Centers of Excellence members and posted on the SNMMI website. Data were collected from May 2018 to August 2018. Analyses were conducted using SAS Software 9.4 with the NPAR1WAY procedure. Differences were evaluated using the Kruskal-Wallis test with statistical significance defined as P ≤ 0.05.
A total of 124 people responded to the survey, 71.8% (89/124) in the USA, and 26.6% (33/124) outside the USA [1.6% (2/124) no response]. 81.5% (101/124) read inpatient PET/CTs. Median percent of inpatient PET/CTs was 8.0% (range 0-100). Use of inpatient PET/CT was different (P < 0.0001) in the USA (5%, range 0-80%) versus outside USAunity nonteaching institutions the least. Results of this survey may help physicians evaluate whether their practice of providing inpatient PET/CT fits with current practice patterns.
Sentinel node biopsy is considered the standard of care in early-stage breast cancer patients. In the current study, we evaluated the effect of radiotracer reinjection in the case of sentinel node nonvisualization on preoperative lymphoscintigraphy.
Between March 2017 and March 2020, 1850 early-stage breast cancer patients were referred for sentinel node mapping. All patients received a single injected activity of Tc-99m Phytate intradermally in the periareolar area of the index lesion using an insulin syringe. Lymphoscintigraphy images of the patients were done 1-2 h postinjection. Between March 2017 and September 2017, sentinel node nonvisualization was reported to the surgeon, and for the rest of the study period, the patients received another injected activity of the radiotracer, and immediately, other lymphoscintigraphy images were taken (with the same parameters).
A total of 255 patients entered our study. Fifty-five patients were in group I without any reinjection. The remainder of the patients were in group II. In 155 out of 200 patients of group II, a sentinel node could be visualized following reinjection of the radiotracer. The detection rate was 15 out of 45 and 15 out of 55 in group I and patients without sentinel node visualization even after reinjection, respectively. Axilla was involved in 5 out of 40 (12.5%) patients in group I with intraoperative sentinel node mapping failure. On the other hand, axilla was involved in 27 out of 30 (90%) group II patients with sentinel node nonvisualization.
Reinjection of the tracer in cases of no sentinel node visualization in lymphoscintigraphy for breast cancer increases the detection rate of sentinel nodes, and therefore a high number of unnecessary axillary lymph node dissections can be avoided.
Reinjection of the tracer in cases of no sentinel node visualization in lymphoscintigraphy for breast cancer increases the detection rate of sentinel nodes, and therefore a high number of unnecessary axillary lymph node dissections can be avoided.Many human cancers predominantly metastasize to the bone which causes bone pain and other symptoms. However, the management of bone metastases is challenging. Radionuclide therapy using low-energy beta-emitting radionuclides has yielded encouraging results. The aim of this therapy is to deliver the maximum dose to the metastatic sites but a minimal dose to the normal tissue. Samarium-153 [153Sm]Sm-Ethylenediamine tetramethylene phosphonate (EDTMP) is an FDA and European Medicine Agency approved (Quadramet) radionuclide and is widely used for bone pain palliation. 153Sm is reactor produced, and the presence of europium impurities is thus unavoidable. This in turn causes an increase in the hospital radioactive waste burden and in radiation absorbed doses to the patients, and therefore it is a concern. The effective removal of these impurities is thus highly desirable before its administration to the patients. In this article, we present a detailed review of the various methods described in the literature for separation of 153Sm and Eu, that is solvent extraction, ion-exchange chromatography, electrochromatography, electrochemical separation and supported ionic liquid phase.