Hydroureteronephrosis with acute urinary tract obstruction can lead to serious complications such as obstructive nephropathy or pyelonephritis. We report the first case of hydroureteronephrosis caused by a giant fecaloma in an 83-year-old woman accompanied with chronic constipation in Korea. The patient with a fever presented to the emergency room and was diagnosed with right hydronephrosis. Computed tomography revealed a markedly dilated rectum with a giant fecaloma compressing the right vesicoureteric junction. Hydroureteronephrosis was resolved through manual disimpaction of the fecaloma and simultaneous lavage with rectal tubes, which improved the acute pyelonephritis and renal function. Chronic constipation can lead to giant fecaloma threatening urinary tract patency, especially in older patients with immobility or dehydration. Therefore, clinicians should consider this condition as a rare but possible cause of hydronephrosis in older adult patients with chronic constipation.
To report a unique surgical procedure that was utilized to locate a missing vibrator in the pelvis of a patient. Emergency room admissions and surgery secondary to the malfunctioning of devices intended for sexual stimulation are extremely common. Emergency room staff of hospitals in the United States usually are skilled in the detection and removal of these devices. Occasionally, surgical intervention is warranted if the device enters a cavity that cannot safely be explored in the emergency room setting. We report a case of a vibrator that was lost during sexual activity. A flat plate X-ray showed it to be in the abdominal cavity. Careful questioning of the patient revealed that the device had an unusually small diameter. Surgical intervention showed that the device ultimately ended up in the bladder without causing traumatic injury.
We created a narrated video to demonstrate the surgical procedure (Canadian Task Force Classification III).
Laparoscopy and cystoscopy were used to visualize and successfully remove the device. The patient recovered uneventfully.
Following laparoscopic confirmation of the location of the device, it was removed via cystoscopy. This case demonstrates how background information, such as the size of the missing device in this case, can be critical to providing high quality patient care.
Following laparoscopic confirmation of the location of the device, it was removed via cystoscopy. This case demonstrates how background information, such as the size of the missing device in this case, can be critical to providing high quality patient care.
Parity is associated with an increased risk of pelvic floor muscle dysfunction. The aim of this study was to evaluate the long-term effects of parity on this musculature.
This cross-sectional study was completed at the Department of Physical Therapy, Federal University of São Carlos, Brazil. In total, 143 women participated in the study and were classified into three groups according to parity nulliparae, primiparae, and secundiparae women. All parous participants had last given birth between 1 and 6 years prior. Pelvic floor muscle function was assessed through unidigital vaginal palpation using the PERFECT scheme, with the contraction grade classified according to the Modified Oxford Scale and through manometry.
There was no difference in scores on the Modified Oxford Scale (the means and standard deviations were 2.5±0.8 in nulliparae women, 2.3±0.9 in primiparae women, and 2.2±0.9 in secundiparae women; P=0.482) and manometry findings (the means and standard deviations were 42.3±22.7 in nulliparae women, 35.0±21.8 in primiparae women, and 33.2±20.0 in secundiparae women; P=0.144) among the assessed groups.
Parity had no effect, regardless of mode of birth, on the function of pelvic floor muscles and the presence of urinary symptoms, such as long-term urinary incontinence after birth.
Parity had no effect, regardless of mode of birth, on the function of pelvic floor muscles and the presence of urinary symptoms, such as long-term urinary incontinence after birth.It is a well-known fact that following a proper routine light/dark or diurnal rhythm controls almost all biological processes. With the introduction of modern lighting and artificial illumination systems, continuous exposure to light at night may lead to the disruption of diurnal rhythm. However, the effect of light during the night on brain anatomy, physiology, and human body functions is less explored and poorly understood. In this study, we have evaluated the effect of exposure to dim light (5 lux) at night (dLAN) on Swiss Albino mice over a duration of three consecutive weeks. Niraparib manufacturer Results have revealed that exposure to dLAN led to an impairment of cognitive and non-cognitive behaviour, oxidative stress-mediated elevation of lipid peroxidation, and reduction of superoxide dismutase and catalase activity. It also led to the downregulation of hippocampal proteins (BDNF, Synapsin II and DCX) at both protein and mRNA level. Additionally, there was downregulation of CREB and SIRT1 mRNAs and neurodegeneration-associated miRNA21a-5p and miRNA34a-5p. The pyramidal and cortical neurons started showing pyknotic and chromatolysis characteristics. However, a dose of curcumin administered to the mice positively modulated these parameters in our experimental animals. We proposed the modulatory role of curcumin in addressing the deleterious effects of dLAN.The incorporation of kenaf fiber fillers into a polymer matrix has been pronounced in the past few decades. In this study, the effect of multiwalled carbon nanotubes (MWCNTs) with a short kenaf fiber (20 mesh) with polypropylene (PP) added was investigated. The melt blending process was performed using an internal mixer to produce polymer composites with different filler contents, while the suitability of this melt composite for the injection molding process was evaluated. Thermogravimetric analysis (TGA) was carried out to investigate the thermal stability of the raw materials. Rheological analyses were conducted by varying the temperature, load factor, and filler content. The results demonstrate a non-Newtonian pseudoplastic behavior in all samples with changed kenaf fillers (10 to 40 wt %) and MWCNT contents (1 to 4 wt %), which confirm the suitability of the feedstock for the injection molding process. The addition of MWCNTs had an immense effect on the viscosity and an enormous reduction in the feedstock flow behavior.