Pritchardlange3627
Three-dimensional (3D) multimodal magnetic resonance (MR) image registration aims to align similar things in different MR images spatially. Such a technology is useful in auxiliary disease diagnosis and surgical treatment. However, inconsistent intensity correspondence and large initial displacement contribute to the difficulty in registering multimodal MR volumes. A coarse-to-fine method is proposed in this study for pairwise 3D MR image rigid registration. Firstly, the proposed method extracts image feature points to form unregistered point sets and performs coarse registration based on point set registration to reduce the initial displacements of offset images effectively. Then, this method calculates a grey histogram based on voxels in the adaptive region of interest and further improves registration accuracy by maximizing mutual information of coarse-registered images. Some representative registration methods are compared on the basis of three MR image datasets to evaluate the performance of the proposed method. Experimental results show that the proposed method improved more in registration success rate and accuracy compared with conventional registration methods, especially when initial displacements are large.
This study examined accuracy of perceived lifetime risk of colorectal cancer prior to and following receipt of cancer risk assessment (CRA) feedback among average risk adults. The specific aims were to identify predictors of improved risk perceptions and assess whether improvement in perceived lifetime risk accuracy was associated with changes in behavioral intentions for physical activity, diet, and colorectal cancer screening.
Adults with no known history of colorectal cancer (n = 419) were enrolled in a study examining the impact of colorectal cancer risk assessment feedback. Risk perceptions and behavioral intentions were ascertained before and after risk assessment administration.
Accuracy of perceived lifetime risk significantly improved after CRA feedback, often as a result of lowered perceived risk. Those who were White, married, attended some college, and had higher numeracy were more likely to report accurate lifetime risk post-CRA. No differences in behavioral intentions were reported between those with and without improved accuracy.
Minorities and those with low numeracy were less likely to report accurate perceptions post-CRA. selleck kinase inhibitor Although improved accuracy was not associated with increased behavioral intentions as expected, it is reassuring that intentions for health behaviors were not inhibited as perceived risk decreased.
Minorities and those with low numeracy were less likely to report accurate perceptions post-CRA. Although improved accuracy was not associated with increased behavioral intentions as expected, it is reassuring that intentions for health behaviors were not inhibited as perceived risk decreased.A GOx/HRP@ZIF-90 nanomaterial is proposed by coating GOx and HRP in ZIF-90 using a bio-simulated mineralization method to improve the tolerance of the enzyme to the external environment. In the detection process, the ZIF-90 is turned on under mild conditions by the competitive reaction of ATP with Zn2+ and imidazole-2-carboxaldehyde (2-ICA), and the electrical signal of the system is amplified by the enzyme cascade reaction of GOx and HRP. Finally, based on the signal amplification strategy of the competitive reaction between Zn2+ and ATP to construct a "signal on" mode, electrochemical immunosensor of GOx-HRP enzyme-linked cascade reaction was prepared. The proposed electrochemical immunosensor shows an excellent analytical performance when detecting CA-125, with good selectivity and stability, with a detection range of 0.1 pg mL-1-40 ng mL-1 and a detection limit of 0.05 pg mL-1. The test has been performed using chronoamperometry under a constant voltage of -0.4 V. The immunosensor also shows an excellent performance when analysing human blood samples. The recovery of the immunosensor is 97.94-101.8%, with a relative standard deviation of 3.7-6.1%. The proposed sensor provides a novel idea for clinical use of GOx and HRP enzymes and a new method for the clinical detection of tumor markers.The average life expectancy for cystic fibrosis (CF) has increased over the past four decades resulting in a higher rate of adult CF patients. Adults seeking lung transplant to address CF-related advanced lung disease (ALD) represent a small, yet growing, subset of lung transplant recipients. Psychosocial factors such as adherence to medical recommendations, self-management of medical care, and caregiver support have been identified as positive prognostic factors in lung transplant outcomes. These factors are also implicated in the pediatric chronic illness literature and are crucial as patients begin to transition to a more autonomous and independent role in their own health management. Adults with CF facing ALD must navigate through another transitional phase as lung transplant requires additional supports and new expectations. A case series is used to highlight specific psychosocial considerations in this population and to explore the seemingly dichotomous relationship between independent self-management and caregiver support.The aim of the present study was to observe the changes of TTX-R, Nav1.8, and Nav1.9 Na+ currents in MSU-induced gouty arthritis mice, and to explore the possibility of Nav1.8 and Nav1.9 channels as potential targets for gout pain treatment. Acute gouty arthritis was induced by monosodium urate (MSU) in mice. Swelling degree was evaluated by measuring the circumference of the ankle joint. Mechanical allodynia was assessed by applying the electronic von Frey. Na+ currents were recorded by patch-clamp techniques in acute isolated dorsal root ganglion (DRG) neurons. MSU treatment significantly increased the swelling degree of ankle joint and decreased the mechanical pain threshold. The amplitude of TTX-R Na+ current was significantly increased and reached its peak on the 4th day after injection of MSU. For TTX-R Na+ channel subunits, Nav1.8 current density was significantly increased, but Nav1.9 current density was markedly decreased after MSU treatment. MSU treatment shifted the steady-state activation curves of TTX-R Na+ channel, Nav1.8 and Nav1.9 channels, and the inactivation curves of TTX-R Na+ channel and Nav1.8 channels to the depolarizing direction, but did not affect the inactivation curve of Nav1.9 channel. Compared with the normal group, the recovery of Nav1.8 channel was faster, while that of Nav1.9 channel was slower. The recovery of TTX-R Na+ channel remained unchanged after MSU treatment. Additionally, MSU treatment increased DRG neurons excitability by reducing action potential threshold. Nav1.8 channel, not Nav1.9 channel, may be involved in MSU-induced gout pain by increasing nerve excitability.
At this juncture, there is no consensus in the literature for the use and the safety of pin-type head holders in cranial procedures.
The present analysis of the bone response to the fixation of the instrument provides data to understand its impact on the entire skull as well as associated complications. An experimental study was conducted on fresh-frozen human specimens to analyze the puncture hole due to the fixation of each single pin of the pin-type head holder. Cone-beam CT images were acquired to measure the diameter of the puncture hole caused by the instrument according to several parameters the pin angle, the clamping force, and different neurosurgical approaches most clinically used.
The deepest hole, 2.67 ± 0.27 mm, was recorded for a 35° angle and a clamping force of 270 N at the middle fossa approach. The shallowest hole was 0.62 ± 0.22 mm for the 43° angle with a pinning force of 180 N in the pterional approach. The pterional approach had a significantly different effect on the depth of the puncture hole compared with the middle fossa craniotomy for 270 N pinning at 35° angle. The puncture hole measured with the 43° angle and 180 N force in prone position is significantly different from the other approaches with the same force.
These results could lead to recommendations about the use of the head holder depending on the patient's history and cranial thickness to reduce complications associated with the pin-type head holder during clinical applications.
These results could lead to recommendations about the use of the head holder depending on the patient's history and cranial thickness to reduce complications associated with the pin-type head holder during clinical applications.
The mean age of actively treated subarachnoid hemorrhage (SAH) patients is increasing. We aimed to compare outcomes and prognostic factors between older and younger SAH patients.
A retrospective single-center analysis of aneurysmal SAH patients admitted to a neuro-ICU during 2014-2019. We defined older patients as ≥70 years and younger patients as <70 years. For every older patient, we identified three younger patients with the same World Federation of Neurological Surgeons (WFNS) grade. We only included patients receiving active aneurysm treatment. Favorable functional outcome, defined as a Glasgow Outcome Scale (GOS) of 4-5 at 12 months, was our primary outcome. We used logistic regression to compare prognostic factors between the groups.
Ninety-five (85%) of 112 older patients and 317 (94%) of 336 younger patients received aneurysm treatment. Of the younger patients, 91% with a good-grade SAH (WFNS I-III) had a favorable outcome compared to 52% in the older good-grade SAH group. In poor-grade patients (WFNS IV-V), favorable outcome was seen in 51% of younger patients, compared to 24% of older patients. Acute hydrocephalus and intracerebral hemorrhage were associated with unfavorable outcome in the younger (OR 4.7, 95% CI 2.6-8.4, and OR 3.7, 95% CI 2.1-6.4), but not in the older patients (OR 1.8, 95% CI 0.8-4.2, and OR 1.3, 95% CI 0.5-3.1, respectively).
In actively treated SAH patients, age was a major determinant of outcome. Factors reflecting increases in intracranial pressure associated with outcome only among younger patients.
In actively treated SAH patients, age was a major determinant of outcome. Factors reflecting increases in intracranial pressure associated with outcome only among younger patients.
Holographic neuronavigation has several potential advantages compared to conventional neuronavigation systems. We present the first report of a holographic neuronavigation system with patient-to-image registration and patient tracking with a reference array using an augmented reality head-mounted display (AR-HMD).
Three patients undergoing an intracranial neurosurgical procedure were included in this pilot study. The relevant anatomy was first segmented in 3D and then uploaded as holographic scene in our custom neuronavigation software. Registration was performed using point-based matching using anatomical landmarks. We measured the fiducial registration error (FRE) as the outcome measure for registration accuracy. A custom-made reference array with QR codes was integrated in the neurosurgical setup and used for patient tracking after bed movement.
Six registrations were performed with a mean FRE of 8.5mm. Patient tracking was achieved with no visual difference between the registration before and after movement.