All reagents were pre-stored within the disk and sample-to-answer processing took less then 3 h using a compact, customized processing device. A technical feasibility study (25 OralDisks) was conducted using samples from healthy, periodontitis and caries patients. The comparison of the OralDisk with a lab-based reference method revealed a ~90% agreement amongst targets detected as positive and negative. This shows the OralDisk's potential and suitability for inclusion in larger prospective implementation studies in dental care settings.The long non-coding RNA (lncRNA) MALAT1 acts as an oncogene. RNA interference (RNAi) is an effective method to control the expression of specific genes and can be used for the treatment of tumors, but an effective and safe carrier system is a significant obstacle to gene therapy. Herein, we explored the possibility of constructing an in situ bio-responsive self-assembled fluorescent gold-short hairpin RNA nanocomplex (Au-shRNA NCs) delivery system by co-incubating gold and MALAT1-shRNA for precise hepatocellular carcinoma (HCC) imaging and treatment. Due to the characteristics of the cancer microenvironment, Au-shRNA NCs self-assembled in HCC cells (HepG2) but did not occur in control cells (L02) under the same conditions. The in situ bio-responsive self-assembled Au-shRNA NCs delivery system can realize cancer cell bioimaging and promote cell uptake and endosomal escape mechanism, thereby realizing effective transfection. They effectively silenced target gene MALAT1, and with the downregulation of MALAT1, we found that several molecules involved in autophagic flux were also regulated. In vitro and tumor-bearing mouse model experiments demonstrated that the as-prepared fluorescent Au-shRNA NCs can readily realize tumor bioimaging and effectively silence the target gene MALAT1, and those autophagy-related pathway molecules were significantly downregulated, thereby exerting a tumor suppressor efficiency. This raises the possibility of realizing accurate multi-scale bio-imaging from the molecular-level with targeted gene-recognition to cancer cell imaging as well as in vivo tumor tissue imaging for the simultaneous precise cancer therapy.Copper nanoclusters (Cu NCs) with their inherent optical and chemical advantages have gained increasing attention as a kind of novel material that possesses great potential, primarily in the use of contaminants sensing and bio-imaging. With a focus on environmental safety, this article comprehensively reviews the recent advances of Cu NCs in the application of various contaminants, including pesticide residues, heavy metal ions, sulfide ions and nitroaromatics. The common preparation methods and sensing mechanisms are summarized. The typical high-quality sensing probes based on Cu NCs towards various target contaminants are presented; additionally, the challenges and future perspectives in the development and application of Cu NCs in monitoring and analyzing environmental pollutants are discussed.The level of pyrophosphatase (PPase) expression has been suggested as a potential biomarker of various cancers, and its prognostic value has been evaluated in patients suffering from lung cancer, colorectal cancer, and hyperthyroidism. However, the detection of PPase usually needs specific materials that require complicated, time-consuming reactions with restricted linear range and sensitivity, limiting their application in early clinical diagnosis. Herein, we developed a DNAzyme-based biosensor for the detection of PPase. In the presence of PPase, pyrophosphate (PPi) and Cu2+ ions released from the PPi-Cu2+-PPi complex induce the cleavage of the DNAzyme and the corresponding substrate. An apurinic/apyrimidinic (AP) site was elaborately designed within substrates that could encase the fluorophore 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND). The fluorescence of ATMND was initially quenched but restored when the DNAzyme/substrate complex was hydrolyzed with the release of ATMND. In this way, the PPase activity can be estimated by detecting the increased fluorescence of the released ATMND. Under optimized conditions, the activity of PPase could be analyzed at concentrations from 0.5 to 1000 mU, with the lowest detectable concentration being 0.5 mU. This work lays a foundation for developing a DNAzyme-amplified fluorescent biosensor with a high sensitivity, a wide linear range, and single-step operation for use as an easy diagnostic for PPase analysis.Based on the necessity and urgency of detecting infectious disease marker procalcitonin (PCT), a novel unlabeled photoelectrochemical (PEC) immunosensor was prepared for the rapid and sensitive detection of PCT. Firstly, SnO2 porous nanoflowers with good photocatalytic performance were prepared by combining hydrothermal synthesis and calcining. BiOI nanoflowers were synthesized by facile ultrasonic mixed reaction. Ag2S quantum dots were deposited on SnO2/BiOI composites by in situ growth method. The SnO2/BiOI/Ag2S composites with excellent photoelectric properties were employed as substrate material, which could provide significantly enhanced and stable signal because of the energy level matching of SnO2, BiOI and Ag2S and the good light absorption performance. Accordingly, a PEC immunosensor based on SnO2/BiOI/Ag2S was constructed by using the layered modification method to achieve high sensitivity analysis of PCT. The linear dynamic range of the detection method was 0.50 pg·mL-1~100 ng·mL-1, and the detection limit was 0.14 pg·mL-1. In addition, the designed PEC immunosensor exhibited satisfactory sensitivity, selectivity, stability and repeatability, which opened up a new avenue for the analyzation of PCT and further provided guidance for antibiotic therapy.Infectious agents, especially bacteria and viruses, account for a vast number of hospitalisations and mortality worldwide. Providing effective and timely diagnostics for the multiplicity of infectious diseases is challenging. Conventional diagnostic solutions, although technologically advanced, are highly complex and often inaccessible in resource-limited settings. An alternative strategy involves convenient rapid diagnostics which can be easily administered at the point-of-care (POC) and at low cost without sacrificing reliability. Biosensors and other rapid POC diagnostic tools which require biorecognition elements to precisely identify the causative pathogen are being developed. The effectiveness of these devices is highly dependent on their biorecognition capabilities. Naturally occurring biorecognition elements include antibodies, bacteriophages and enzymes. Recently, modified molecules such as DNAzymes, peptide nucleic acids and molecules which suffer a selective screening like aptamers and peptides are gaining interest for their biorecognition capabilities and other advantages over purely natural ones, such as robustness and lower production costs. Antimicrobials with a broad-spectrum activity against pathogens, such as antibiotics, are also used in dual diagnostic and therapeutic strategies. Other successful pathogen identification strategies use chemical ligands, molecularly imprinted polymers and Clustered Regularly Interspaced Short Palindromic Repeats-associated nuclease. Herein, the latest developments regarding biorecognition elements and strategies to use them in the design of new biosensors for pathogens detection are reviewed.The measurement of cysteine in human urine and live cells is crucial for evaluating biological metabolism, monitoring and maintaining the immune system, preventing tissue/DNA damage caused by free radicals, preventing autoimmune diseases, and diagnosing disorders such as cystinuria and cancer. A method that uses a fluorescence turn-on probe and a portable fluorescence spectrometer device are crucial for highly sensitive, simple, rapid, and inexpensive cysteine detection. Herein, we present the synthesis and application of a benzimidazole-based fluorescent probe (ABIA) along with the design and development of a portable fluorescence spectrometer device (CysDDev) for detecting cysteine in simulated human urine. ABIA showed excellent selectivity and sensitivity in detecting cysteine over homocysteine, glutathione, and other amino acids with the response time of 1 min and demonstrated a detection limit of 16.3 nM using the developed CysDDev. Further, ABIA also demonstrated its utility in detecting intracellular cysteine, making it an excellent probe for bio-imaging assay.Masses are one of the early signs of breast cancer, and the survival rate of women suffering from breast cancer can be improved if masses can be correctly identified as benign or malignant. However, their classification is challenging due to the similarity in texture patterns of both types of mass. The existing methods for this problem have low sensitivity and specificity. Based on the hypothesis that diverse contextual information of a mass region forms a strong indicator for discriminating benign and malignant masses and the idea of the ensemble classifier, we introduce a computer-aided system for this problem. The system uses multiple regions of interest (ROIs) encompassing a mass region for modeling diverse contextual information, a single ResNet-50 model (or its density-specific modification) as a backbone for local decisions, and stacking with SVM as a base model to predict the final decision. A data augmentation technique is introduced for fine-tuning the backbone model. The system was thoroughly evaluated on the benchmark CBIS-DDSM dataset using its provided data split protocol, and it achieved a sensitivity of 98.48% and a specificity of 92.31%. Furthermore, it was found that the system gives higher performance if it is trained and tested using the data from a specific breast density BI-RADS class. The system does not need to fine-tune/train multiple CNN models; it introduces diverse contextual information by multiple ROIs. The comparison shows that the method outperforms the state-of-the-art methods for classifying mass regions into benign and malignant. It will help radiologists reduce their burden and enhance their sensitivity in the prediction of malignant masses.Recent advances suggest that miniaturised mid-infrared (MIR) devices could replace more time-consuming, laboratory-based techniques for clinical diagnostics. This work uses Fourier transform infrared spectroscopy to show that the MIR complex refractive index of whole blood varies across a range of haematocrit. This indicates that the use of an evanescent measurement is not sufficient to optically exclude the cellular content of blood in the MIR, as previously assumed. Here, spectral refractive index data is presented in two ways. First, it is given as whole blood with varying haematocrit. Second, it is given as the percentage error that haematocrit introduces to plasma. GSK343 supplier The maximum error in the effective plasma refractive index due to the haematocrit of healthy adults was 0.25% for the real part n and 11% for the imaginary part k. This implies that calibration measurements of haematocrit can be used to account for errors introduced by the cellular content, enabling plasma spectra and analyte concentrations to be indirectly calculated from a whole blood sample. This methodological advance is of clinical importance as plasma concentration of analytes such as drugs can be determined using MIR without the preprocessing of whole blood.