Hypertensive disorders of pregnancy account for approximately 22% of all maternal deaths in Latin America and the Caribbean. Pharmacotherapies play an important role in preventing and reducing the occurrence of adverse outcomes. However, the patterns of medications used for treating women with hypertensive disorders of pregnancy (HDP) living in this country is unclear. A population-based birth cohort study including 4262 women was conducted to describe the pattern of use of cardiovascular agents and acetylsalicylic acid between women with and without HDP in the 2015 Pelotas (Brazil) Birth Cohort. LC2 The prevalence of maternal and perinatal outcomes in this population was also assessed. HDP were classified according to Ministry of Health recommendations. Medications were defined using the Anatomical Therapeutic Chemical Classification System and the substance name. In this cohort, 1336 (31.3%) of women had HDP. Gestational hypertension was present in 636 (47.6%) women, 409 (30.6%) had chronic hypertension, 191 (14.3%) pre-eclampsia, and 89 (6.7%) pre-eclampsia superimposed on chronic hypertension. Approximately 70% of women with HDP reported not using any cardiovascular medications. Methyldopa in monotherapy was the most frequent treatment (16%), regardless of the type of HDP. Omega-3 was the medication most frequently reported by women without HDP. Preterm delivery, caesarean section, low birth weight, and neonatal intensive care admissions were more prevalent in women with HDP. Patterns of use of methyldopa were in-line with the Brazilian guidelines as the first-line therapy for HDP. However, the large number of women with HDP not using medications to manage HDP requires further investigation.COVID-19, a global pandemic causing to date more than 50 million cases and more than a million deaths, has to be controlled. SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) was identified as the causative agent. Controversy about this virus origin and infectious mechanism for adapting to humans remains a matter for discussion. Among all strategies for obtaining safe and potent vaccines, approaches based on attenuated-killed virus and non-replicating RNA viral vectors are demonstrating promising results. However, specificity of viral components targeted by human antibodies so far has not been demonstrated. A consistent strategy for obtaining functional-active antigens from SARS-CoV-2 specific ligands lead us to propose and test a number of synthetic components. From hundreds of starting sequences only fifteen fulfilled the design requirements and were produced as monomer and polymer forms and immuno-chemically tested. The design was based on worldwide representative reported virus genomes. A bioinformatics scheme by conventional methods and knowledge on MHC-I and II antigen processing mechanisms and HLA haplotype-restriction was performed including sensitive and resistant human populations to virus infection. Covid-19 patients' sera reactivity for synthetic SARS-CoV-2-designed components have proven a high recognition of specific molecules, as well as some evidence for a long-lasting humoral immune response.Transparent and amorphous yttrium (Y)/Sialon thin films were successfully fabricated using pulsed laser deposition (PLD). The thin films were fabricated in three steps. First, Y/Sialon target was synthesized using spark plasma sintering technique at 1500 °C in an inert atmosphere. Second, the surface of the fabricated target was cleaned by grinding and polishing to remove any contamination, such as graphite and characterized. Finally, thin films were grown using PLD in an inert atmosphere at various substrate temperatures (RT to 500 °C). While the X-ray diffractometer (XRD) analysis revealed that the Y/Sialon target has β phase, the XRD of the fabricated films showed no diffraction peaks and thus confirming the amorphous nature of fabricated thin films. XRD analysis displayed that the fabricated thin films were amorphous while the transparency, measured by UV-vis spectroscopy, of the films, decreased with increasing substrate temperature, which was attributed to a change in film thickness with deposition temperature. X-ray photoelectron spectroscopy (XPS) results suggested that the synthesized Y/Sialon thin films are nearly homogenous and contained all target's elements. A scratch test revealed that both 300 and 500 °C coatings possess the tough and robust nature of the film, which can resist much harsh loads and shocks. These results pave the way to fabricate different Sialon doped materials for numerous applications.Polymyxin B is the last line of defense in treating multidrug-resistant gram-negative bacterial infections. Dosing of polymyxin B is currently based on total body weight, and a substantial intersubject variability has been reported. We evaluated the performance of different population pharmacokinetic models to predict polymyxin B exposures observed in individual patients. In a prospective observational study, standard dosing (mean 2.5 mg/kg daily) was administered in 13 adult patients. Serial blood samples were obtained at steady state, and plasma polymyxin B concentrations were determined by a validated liquid chromatography tandem mass spectrometry (LC-MS/MS) method. The best-fit estimates of clearance and daily doses were used to derive the observed area under the curve (AUC) in concentration-time profiles. For comparison, 5 different population pharmacokinetic models of polymyxin B were conditioned using patient-specific dosing and demographic (if applicable) variables to predict polymyxin B AUC of the same patient. The predictive performance of the models was assessed by the coefficient of correlation, bias, and precision. The correlations between observed and predicted AUC in all 5 models examined were poor (r2 less then 0.2). Nonetheless, the models were reasonable in capturing AUC variability in the patient population. Therapeutic drug monitoring currently remains the only viable approach to individualized dosing.Rapid molecular diagnostic assays are increasingly used to guide effective antimicrobial therapy. Data on their effectiveness to decrease antimicrobial use in children have been limited and varied. We aimed to assess the impact of the implementation of the FilmArray Meningitis Encephalitis Panel (MEP) on antimicrobial use and outcomes in children. In an observational retrospective study performed at Atlantic Health System (NJ), we sought to evaluate the duration of intravenous antibiotic treatment (days of therapy (DoT)) for patients less then 21 years of age hospitalized and evaluated for presumptive meningitis or encephalitis before and after the introduction of the MEP. A secondary analysis was performed to determine if recovery of a respiratory pathogen influenced DoT. The median duration of antibiotic therapy prior to the implementation of the MEP was 5 DoT (interquartile range (IQR) 3-6) versus 3 DoT (IQR 1-5) (p less then 0.001) when MEP was performed. The impact was greatest on intravenous third-generation cephalosporin and ampicillin use. We found a reduction in the number of inpatient days associated with the MEP. In the regression analysis, a positive respiratory pathogen panel (RPP) was not a significant predictor of DoT (p = 0.08). Furthermore, we found no significant difference between DoT among patients with negative and positive RPP (p = 0.12). Our study supports the implementation of rapid diagnostics to decrease the utilization of antibiotic therapy among pediatric patients admitted with concerns related to meningitis or encephalitis.Immunoassay has the advantages of high sensitivity, high specificity, and simple operation, and has been widely used in the detection of mycotoxins. For several years, time-resolved fluorescence immunochromatography (TRFIA) paper-based sensors have attracted much attention as a simple and low-cost field detection technology. However, a traditional TRFIA paper-based sensor is based on antibody labeling, which cannot easily meet the current detection requirements. A second antibody labeling method was used to amplify the fluorescence signal and improve the detection sensitivity. Polystyrene fluorescent microspheres were combined with sheep anti-mouse IgG to prepare fluorescent probes (Eu-IgGs). After the probe fully reacted with the antibody (Eu-IgGs-Abs) in the sample cell, it was deployed on the paper-based sensor using chromatography. Eu-IgGs-Abs that were not bound to the target were captured on the T-line, while those that were bound were captured on the C-line. The paper-based sensor reflected the corresponding fluorescence intensity change. Because a single molecule of the deoxynivalenol antibody could bind to multiple Eu-IgGs, this method could amplify the fluorescence signal intensity on the unit antibody and improve the detection sensitivity. The working standard curve of the sensor was established under the optimum working conditions. It showed the lower limit of detection and higher recovery rate when it was applied to actual samples and compared with other methods. This sensor has the advantages of high sensitivity, good accuracy, and good specificity, saving the amount of antibody consumed and being suitable for rapid field detection of deoxynivalenol.A hydraulic axial piston pump is the essential component of a hydraulic transmission system and plays a key role in modern industry. Considering varying working conditions and the implicity of frequent faults, it is difficult to accurately monitor the machinery faults in the actual operating process by using current fault diagnosis methods. Hence, it is urgent and significant to investigate effective and precise fault diagnosis approaches for pumps. Owing to the advantages of intelligent fault diagnosis methods in big data processing, methods based on deep learning have accomplished admirable performance for fault diagnosis of rotating machinery. The prevailing convolutional neural network (CNN) displays desirable automatic learning ability. Therefore, an integrated intelligent fault diagnosis method is proposed based on CNN and continuous wavelet transform (CWT), combining the feature extraction and classification. Firstly, CWT is used to convert the raw vibration signals into time-frequency representations and achieve the extraction of image features. Secondly, a new framework of deep CNN is established via designing the convolutional layers and sub-sampling layers. The learning process and results are visualized by t-distributed stochastic neighbor embedding (t-SNE). The results of the experiment present a higher classification accuracy compared with other models. It is demonstrated that the proposed approach is effective and stable for fault diagnosis of a hydraulic axial piston pump.
This study aimed to investigate the outcome of therapeutic penetrating keratoplasty (TPK) for medically-uncontrolled infectious keratitis, and to determine the factors associated with the recurrence of infection after TPK.
A 10-year retrospective study of medically-uncontrolled infectious keratitis with positive culture results, who received TPK at a tertiary referral center in Korea was performed. Data collection included patient demographics, medical history, pre- and post-operative findings, surgical procedures, causative microorganisms, and visual acuities (VA). The primary outcome measure was the recurrence of infection after TPK, and the factors were compared between patients with and without recurrence.
A total of 19 patients (19 eyes) were analyzed, of which 6 eyes (31.6%) had infection recurrence at 21.6 ± 22.84 months after TPK. Recurrence occurred more frequently in the female sex (vs. male,
= 0.013) and in longer duration (>30 days) from infection onset to TPK (vs. ≤30 days,
= 0.025).