Mahmoudsimpson4117
Numerous techniques of pupilloplasty have been described to restore iris anatomy. However limitations arise in phakic eyes due to the propensity for crystalline lens damage. We describe a novel technique for pupilloplasty in phakic eyes, wherein a plate haptic intraocular lens or phakic intraocular lens provides a scaffold and protects the anterior crystalline lens from subsequent surgical manoeuvres. The technique is demonstrated in a 24-year-old male who presented four months following blunt trauma to his left eye, with complaints of glare and difficulty in near activities secondary to traumatic mydriasis. The use of an intraocular lens scaffold allowed successful pupilloplasty without iatrogenic tissue trauma or subsequent crystalline lens opacification up to one-year follow-up. Our technique affords a safe pupillary repair without damage to the clear crystalline lens or the need for a concomitant lens extraction.Our purpose was assess the long-term efficacy of 4-mm coronary balloon catheter dacryoplasty in revision endoscopic dacryocystorhinostomy (RevEnDCR). This retrospective interventional case-series was performed for patients who underwent RevEnDCR aided by a 4-mm coronary balloon catheter (CBC) dacryoplasty. The indications for the surgery were previously failed DCRs by external or endoscopic approach where the ostium showed near total cicatrization with or without the presence of organized granuloma threatening the internal common opening (ICO). The coronary balloon (4 × 10 mm, SPALNO, Cardiomac, Haryana, India) with the guidewire was used and a minimum of >12 months of follow-up was considered for analysis. Ten lacrimal systems of eight patients with mean age of 48.8 years underwent CBC-assisted revision endoscopic DCR. Of the 10 failed DCRs, 6 had a previous external approach DCR and 4 were endoscopic DCRs. Grossly stenosed ostium with near total cicatricial closure were noted in half of the patients (50%, 5/10) while the remaining half, in addition, showed organized granulomas threatening the ICO. The surgical technique using CBC was found to be minimally invasive, easy to perform with multiple advantages like uniform clearance of the area in front of ICO and more predictable lacrimal sac flaps. At a mean follow-up of 20 months, anatomical and functional success were achieved in 90% (9/10) of the eyes. Mitapivat cost We conclude that coronary balloon catheter-assisted revision endoscopic DCR is a minimally invasive and viable alternative in select group of patients of failed DCR with near total cicatrisation or organized granulomas threatening ICO.There is a massive disruption of the global economy and education due to the coronavirus disease-2019 (COVID-19) pandemic. This has posed significant challenges and threats to the academic community, especially in health care where the learning and assessment are patient centered. Though blended learning had its emphasis in the pre-COVID-19 era, innovations are required to meet up to the increased demands on learning and assessment. This article uses an inductive approach and outlines the existing challenges, impact of COVID-19 era, the need for a mindset reframe, and the potential opportunities for innovations that underlie during these challenging times.Type 1 retinopathy of prematurity (ROP) requires emergency intervention and laser is an established modality of treatment. Laser treatment for ROP under topical anesthesia can be considered as an aerosol-generating procedure due to crying that puts health care workers at high risk of COVID-19 transmission. Aerosol containment box (ACB) is known to minimize aerosol transmission and there are reports of ROP laser done through incubator. Combining these two ideas, we describe a new application of ACB with suction for laser treatment of ROP thereby, reducing risk to health care team without compromising timely effective, and safe treatment for ROP.
The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill.
Surgical techniques were performed ex vivo using the electrosurgical device, scalpel, and mechanized drill on the muscle and bone of commercially available chicken. The liquid and gas dynamics were observed using a high-speed high-resolution Photron SA5 camera (0.125 to 8 ms temporal resolution, 0.016 to 0.054 mm/pixel spatial resolution) and stroboscopic lighting (Veritas 120 E LED Constellation). The analysis was performed using in-house algorithms and ImageJ software.
The use of a mechanized drill at 35000 rpm and a 3 mm fluted burr generated aerosol with particle size 50 to 550 microns with a spread of 1.8 m radius. Surgical smoke was generated by an electrosurgical device in both cutting and coagulation modes. Dispersion of the smoke could be controlled significantly by the use of suction, mean smoke spread ratio being 0.065 without suction and 0.002 with use of suction within 2 cm.
The quantification of the aerosol generation will help surgeons take practical decisions in their surgical techniques in the pandemic era.
The quantification of the aerosol generation will help surgeons take practical decisions in their surgical techniques in the pandemic era.
The aim of this study was to analyze the impact on vision due to delay in presentation of patients requiring intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections, consequent to COVID-19-related travel restrictions.
Data were collected retrospectively of patients who received anti-VEGF injections during four months of the COVID-19 pandemic. Visual acuities, indication for treatment were noted along with basic demographic characteristics.
Data were analyzed for 303 eyes of 263 patients. The indication for treatment was age-related macular degeneration (AMD) in 60 eyes (19.8%), while 162 eyes (53.5%) had Diabetic Macular Edema, 71 eyes (23.4%) had Retinal Vein Occlusion and 10 eyes (3.3%) had other diagnosis. The visual acuity in the treatment naïve eyes (Group A, n = 168) was significantly worse (P <0.001) than those who presented for retreatment (Group B, n = 135). In Group B, there was a significant decline in vision for the entire cohort (P = 0.009) and those with AMD (P = 0.036).