To evaluate visual quality and depth of focus under photopic and mesopic light conditions of patients treated with pinhole pupilloplasty (PPP) for corneal higher order aberrations.

This was a prospective, noncomparative, interventional series and PPP was performed with a single-pass four-throw procedure in 14 eyes of 14 patients. After PPP, patients were analyzed with the Clinical Trial Suite machine (M & S Technologies, Inc) that offers a standardized method of recording visual quality. The luminance levels of 85 and 3 cd/m

were set for photopic and mesopic lighting conditions, respectively, and uncorrected and corrected distance visual acuity were recorded for distance (4 m), intermediate (66 cm), and near (44 cm). Low contrast acuity (LCA) at 10% and mesopic contrast sensitivity function (CSF) with glare on and off at four spatial frequencies of 1.5, 3, 6, and 12 cycles per degree (cpd) and defocus curve were assessed.

Under photopic and mesopic conditions, a significant difference was observed postoperatively in uncorrected and corrected distance visual acuity for distance, intermediate, and near. The defocus curve demonstrated extended depth of focus that ranged from +1.50 to -2.50 diopters and LCA at 10% demonstrated significant improvement for all cases. For mesopic CSF, a significant improvement was noted at spatial frequencies of 3 and 6 cpd with glare on. With glare off, an improvement was seen at spatial frequencies of 1.5, 3, and 6 cpd, but not at 12 cpd.

Early results demonstrate that PPP provides improved visual quality and extended depth of focus and can be a useful option in cases with higher order aberrations. [J Refract Surg. 2020;36(12)812-819.].

Early results demonstrate that PPP provides improved visual quality and extended depth of focus and can be a useful option in cases with higher order aberrations. [J Refract Surg. 2020;36(12)812-819.].

To measure the in vivo longitudinal chromatic aberration (LCA) from the chromatic difference of focus (480 to 700 nm) using psychophysical methods in patients bilaterally implanted with a hydrophobic trifocal intraocular lens (IOL).

Psychophysical best focus was measured in both eyes at different wavelengths (480 to 700 nm) and at three different viewing distances (0.00, +1.75, and +3.50 diopters [D]) using a custom-developed polychromatic adaptive optics set-up provided with a supercontinuum laser, a Hartmann-Shack wavefront sensor, a deformable mirror, a motorized Badal system, a pupil monitoring system, and a psychophysical channel with monochromatically illuminated stimuli. Measurements were performed on 10 patients (20 eyes) bilaterally implanted with hydrophobic trifocal diffractive IOLs (FineVisionHP POD F GF; PhysIOL). LCA was computed from the chromatic difference of focus curves as the difference between 480 and 700 nm at near, intermediate, and far.

The LCA from psychophysical measurements wa will allow optimizing IOL designs to improve polychromatic image quality. [J Refract Surg. 2020;36(12)804-810.].

To evaluate the visual outcomes and patient satisfaction after blended implantation of rotationally asymmetric multifocal intraocular lenses (IOLs) (LENTIS Mplus LS-313 +3.00 and +1.50 diopters [D], Oculentis GmbH).

This was an interventional prospective study that included 40 eyes of 20 patients who underwent uneventful refractive lens exchange. Patients were implanted with the LENTIS Mplus LS-313 +3.00 D IOL in the non-dominant eye and the +1.50 D IOL in the dominant eye. Twelve months after surgery, binocular and monocular uncorrected and corrected near, intermediate, and distance visual acuity, defocus curve, contrast sensitivity, and light distortion analysis (LDA) were evaluated. Monocular total ocular aberrometry with a pyramidal wavefront sensor (Osiris; CSO) and patient satisfaction was evaluated with the 10-item Near Activity Vision Questionnaire (NAVQ-10).

There was a statistically significant improvement in the uncorrected distance visual acuity in both eyes after surgery (P < .001), withe advantages of each IOL, improving binocular visual outcomes and providing good patient satisfaction. [J Refract Surg. 2020;36(12)796-803.].

To investigate the potential benefit of keratoconus surgery using customized corneal stromal donor lenticules obtained from myopic small incision lenticule extraction (SMILE) surgery by femtosecond laser.

In this prospective, consecutive, non-comparative series of cases, 22 lenticules were obtained from 22 myopic patients who had SMILE with a lenticule central thickness of greater than 110 µm. The lenticules were implanted in 22 eyes with advanced keratoconus. The lenticules were customized for the purpose of the implantation with either a simple necklace or necklace-with-ring shape (compound form) depending on the corneal thickness and corneal topography configuration of the implanted keratoconic eyes. AMPK inhibitor The lenticules were implanted into a 9.5-mm corneal lamellar pocket created by the femtosecond laser. Changes in densitometry, thickness, confocal microscopy, corrected distance visual acuity (CDVA), and endothelial cell density were investigated.

Intrastromal lenticule implantation was successfully performed in all cases without any complication. Corneal thickness showed a mean enhancement of 100.4 µm at the thinnest point. On biomicroscopy, all corneas were clear at 1 year postoperatively and there was a significant improvement in corneal densitometry during the entire follow-up period. Confocal biomicroscopy showed collagen reactivation without any inflammatory features caused by the implanted fresh lenticules. CDVA improved from 0.70 to 0.49 logMAR (P = .001) and keratometry decreased from 54.68 ± 2.77 to 51.95 ± 2.21 diopters (P = .006).

Customized SMILE lenticule implantation by femtosecond laser proved to be feasible, resulting in an improvement in vision, topography, and refraction in the implanted eyes. [J Refract Surg. 2020;36(12)786-794.].

Customized SMILE lenticule implantation by femtosecond laser proved to be feasible, resulting in an improvement in vision, topography, and refraction in the implanted eyes. [J Refract Surg. 2020;36(12)786-794.].