- 1 ] and aerosol with optical thickness in the range [ 0.01 - 1 ] .This research utilized a person-centered approach to identify profiles of decent work and precarious work, which were explored due to their centrality in current debates about the uncertain state of work conditions in the U.S. Using the Decent Work Scale and the Precarious Work Scale, the following five profiles were identified from a sample of 492 working Americans 1) Indecent-Precarious; 2) Highly Decent; 3) Low Health Care-Low Rights; 4) Vulnerability-Dominant; 5) Health Care-Stability. These profiles were further elaborated by examining the relationship of theoretically-informed predictors and outcomes that would distinguish profile membership. Using psychology of working theory as an organizing framework for determining predictors and outcomes, the findings revealed that work volition, age, income level, and educational level significantly predicted profile membership, and autonomy, social contribution, survival needs, job satisfaction, and life satisfaction differed meaningfully across the profiles. Implications for theory, research, practice, and public policy are discussed highlighting the complexity of work conditions and their relationship to various aspects of vocational and psychological functioning.
The polymeric porous surface of fibres (PLA) may influence the kinetics of release of biologically active compounds (gentamicin, G and ethacridine lactate, R) affecting development of a bacterial biofilm.
The porous fibres with different morphology were manufactured by the electrospinning method from ternary systems composed of PLA and selected solvents. Fibres morphology was examined using a scanning electron microscopy (SEM), their structure was analyzed by FT-IR ATR spectroscopy and differential scanning calorimetry (DSC). Changes in the drug release profile were measured using ICP/UV-Vis methods and the resulting bactericidal or bacteriostatic properties were tested by two-layer disk diffusion test in relation to various drug incorporation methods.
The porous fibres can be applied to produce drug-bearing membranes. The spectroscopic studies confirmed incorporation of gentamicin into the fibres and the presence of ethacridine lactate on their surface. Bimodal fibres distribution (P3) promoted faster release of gentamicin and ethacridine lactate from P3G and P3R materials. The electrospinning process coupled with the vapor induced phase separation influenced the glass transition temperature of the porous polymer fibres. The pre/post-electrospinning modification influenced the glass transition, maximum temperature of cold crystallization and melting point of the porous membrane, compared to the neat polymer. The polylactide fibres with gentamicin showed strong bactericidal effect on Gram-positive bacteria, while fibres with ethacridine lactate were bacteriostatic.
The obtained fibres with complex surface morphology can be used as a membrane in active dressings as they make it possible to control the release profile of the active compounds.
The obtained fibres with complex surface morphology can be used as a membrane in active dressings as they make it possible to control the release profile of the active compounds.
This study attempted to establish the link between design of implants for bone-anchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract data sets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity.
Three designs were considered threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young's modulus (10 to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 to 18 mm) and thickness of medullar part (5 to 1 mm) was investigated for the modular press-fit implant.
The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass was by 5% lower to press-fit design. The influence of Young's modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and from 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively.
Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.
Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.
The aim of the study was to compare the results of six balance tests collected on AMTI AccuSway Plus ACS force platform between healthy female and male children and adolescents. We also searched for possible correlation of the balance measures with subjects' age.
228 healthy 6- to 18-year-old subjects (111 boys and 117 girls) participated in the study. Six balance tests were performed with the use of AMTI AccuSway Plus ACS platform quiet standing for 30s, maximal voluntary sways of the body in the sagittal plane (anterior-posterior - AP test) for 30 s, and in the frontal plane (left-right - ML test) for 30s. All tests were performed in two conditions eyes open and eyes closed.
During quiet standing with eyes open, most balance measures were lower in girls ( p < 0.05). In AP and ML tests with eyes open, a few balance parameters were different between boys and girls ( p < 0.05). Enzastaurin PKC inhibitor In quiet standing, AP and ML tests with eyes closed, there were no between-gender differences ( p > 0.05). In quiet standing with eyes open and closed most balance parameters were negatively correlated with age ( p < 0.