Huynhblackburn1646
In Italy, a strict lockdown was imposed from 8 March 2020 to stop the spread of the coronavirus disease 2019 (COVID-19). We explored the effect of this lockdown on data transmitted by remote monitoring (RM) of implantable cardioverter and cardiac resynchronization therapy defibrillators (ICDs/CRT-Ds). selleck kinase inhibitor RM daily transmissions from ICDs and CRT-Ds were analyzed and compared in two consecutive 1 month frames pre and post-lockdown period I (7 February-7 March 2020) and period II (8 March-7 April 2020). The study cohort included 180 patients (81.1% male, 63.3% ICDs and 36.7% CRT-Ds) with a median age of 70 (interquartile range 62-78) years. The median value of physical activity provided by accelerometric sensors showed a significant reduction between period I and II [13.1% (8.2-18.1%) versus 9.4% (6.3-13.8%), p less then 0.001]. Eighty nine % of patients decreased their activity, for 43.3% the relative reduction was ≥ 25%. The mean heart rate decreased significantly [69.2 (63.8-75.6) bpm vs 67.9 (62.7-75.3) bpm, p less then 0.001], but with greater reduction (≈3 beats/minute) in patients aged less then 70 years. Resting heart rate and thoracic impedance showed minor variations. No differences were observed in device pacing % and arrhythmias. In cardiac patients, the lockdown imposed to contain COVID-19 outbreak significantly reduced the amount of physical activity and the mean heart rate. These side effects of in-home confinement quarantine should be taken in consideration for frail patients.
The role of hypoalbuminemia and raised C-reactive protein (CRP) levels in predicting critical prognosis has been described extensively in adult literature. However, there are limited studies in pediatrics, particularly neonates. The CRP/albumin (CRP/ALB) ratiois often associated with higher mortality, organ failure and prolonged hospital stay. We hypothesized that the serum CRP/ALB ratio has a prognostic value in predicting surgery and mortality in neonates with necrotizing enterocolitis (NEC).
Retrospective review of all neonates with clinical and radiological evidence of non-perforated NEC that were treated in a tertiary-level referral hospital between 2009 and 2018. General patient demographics, laboratory parameters and outcomes were recorded. Receiver operating characteristics analysis was performed to evaluated optimal cut-offs and area under the curve (AUC) with 95% confidence intervals (CI).
A total of 191 neonates were identified. Of these, 103 (53.9%) were born at ≤ 28weeks of gestation and 101 (52.9%) had a birth weight of ≤ 1000g. Eighty-four (44.0%) patients underwent surgical intervention for NEC. The overall survival rate was 161/191 (84.3%). A CRP/ALB ratio of ≥ 3 on day 2 of NEC diagnosis was associated with a statistically significant higher likelihood for surgery [AUC 0.71 (95% CI 0.63-0.79); p < 0.0001] and mortality [AUC 0.66 (95% CI 0.54-0.77); p = 0.0150], respectively.
A CRP/ALB ratio of ≥ 3 onday 2 is indicative of a critical pathway in neonates with radiologically confirmed, non-perforated NEC. This could be used as an additional criterion to guide parental counselling in NEC for surgical intervention and mortality.
A CRP/ALB ratio of ≥ 3 on day 2 is indicative of a critical pathway in neonates with radiologically confirmed, non-perforated NEC. This could be used as an additional criterion to guide parental counselling in NEC for surgical intervention and mortality.The objective is to understand genetic predisposition to delirium. Following PRISMA guidelines, we undertook a systematic review of studies involving delirium and genetics in the databases of Pubmed, Scopus, Cochrane Library and PsycINFO, and performed a meta-analysis when appropriate. We evaluated 111 articles, of which 25 were finally included in the analysis. The studies were assessed by two independent researchers for methodological quality using the Downs and Black Tool and for genetic analysis quality. We performed a meta-analysis of 10 studies of the Apolipoprotein E (APOE) gene, obtaining no association with the presence of delirium (LOR 0.18, 95% CI - 0.10-0.47, p = 0.21). Notably, only 5 out of 25 articles met established criteria for genetic studies (good quality) and 6 were of moderate quality. Seven studies found an association with APOE4, the dopamine transporter gene SCL6A3, dopamine receptor 2 gene, glucocorticoid receptor, melatonin receptor and mitochondrial DNA haplotypes. One genome-wide association study found two suggestive long intergenic non-coding RNA genes. Five studies found no association with catechol-o-methyltransferase, melatonin receptor or several interleukins genes. The studies were heterogenous in establishing the presence of delirium. Future studies with large samples should further specify the delirium phenotype and deepen our understanding of interactions between genes and other biological factors.
Kidney Stone Calculator (KSC) is a free, three-dimensional (3D) planning software for flexible ureteroscopy(fURS) with HolmiumYAG(HoYAG) endocorporeal lithotripsy (EL). KSC provides the stone volume (SV) and expected duration of lithotripsy (ExDL) estimations based on non-enhanced-CT scan (NECT) DICOM series. We aimed to provide a preclinical and clinical evaluation of KSC.
A preclinical evaluation measured the SV by three operators (resident, endourology expert and research engineer) among 17 NECT cases. Between January and March 2020, a multicentric, prospective, observational double-blind clinical evaluation was conducted in patients presenting with renal stones treated with HoYAG-EL during fURS and preoperative NECT. Demographic and surgical data were collected. The primary endpoint was a significant median difference between ExDL and EffectiveDL (EfDL). Second, efficiency (J/mm
) and efficacy (mm
/min) ratios were calculated.
The preclinical evaluation showed no significant difference in the SV measurements among operators (p > 0.05). Pearson and Kendall coefficients of 0.99 and 0.98, respectively, were found. Twenty-six patients were included in the clinical evaluation, with a median age of 55years. In 66% of cases, there was a single stone located in the lower pole, with a density > 1000Hounsfield Unit observed in 42% and 85% of cases. A 14% [Q1-Q3 (5.4-24.8); p = 0.36] median difference between ExDL and EfDL was noted, which was greater in the case of lower pole stones with no possible relocation (p = 0.008). Median values of 17.6J/mm
and 0.4 (0.32-0.56)mm
/s EL were also noted.
Kidney Stone Calculator is a reproducible and accurate software that allows for an estimation of the stone burden and provides an ExDL for URSf. Defining the influencing factors of EL will improve its ExDL.
Kidney Stone Calculator is a reproducible and accurate software that allows for an estimation of the stone burden and provides an ExDL for URSf. Defining the influencing factors of EL will improve its ExDL.