Hansonmccain1764

Z Iurium Wiki

In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners.

Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures (1.5-T and 3-T) when using TSE with high readout bandwidth.

Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures (1.5-T and 3-T) when using TSE with high readout bandwidth.

This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials.

Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Debio 0123 Wee1 inhibitor Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed.

The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (

>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (

<0.05).

The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

This study was conducted to establish age- and sex-specific reference standards for pterygoid hamulus (PH) dimensions using cone-beam computed tomography (CBCT).

CBCT scans of 1,000 patients (493 males and 507 females) were retrospectively assessed in coronal sections for length and width measurements of the PH by 3 investigators. The study data were divided into 3 age groups (group 1 <20 years, group 2 20-50 years, group 3 >50 years). Length and width were compared using one-way analysis of variance and the t-test for age and sex, respectively.

The length of the PH on the right side significantly increased from group 1 (6.11±1.47 mm), through group 2 (6.65±1.67 mm) to group 3 (6.99±1.79 mm) and on the left side from group 2 (6.58±1.63) to group 3 (6.98±1.70). The width of the PH significantly decreased from group 1 (1.81±0.39 mm) to group 2 (1.61±0.39 mm) on the right side, and similarly from 1.87±0.36 mm to 1.67±0.37 mm on the left side. PH length (7.18±1.81 mm on the right side and 7.10±1.72 mm on the left side) and width (1.68±0.38 mm on the right side and 1.74±0.36 mm on the left side) were significantly greater in males than in females.

The length of the PH increased with age, whereas width first decreased and then increased. Length and width measurements were significantly higher in males than in females. These findings will aid in the diagnosis of untraceable pain in the oropharyngeal region related to altered PH morphology.

The length of the PH increased with age, whereas width first decreased and then increased. Length and width measurements were significantly higher in males than in females. These findings will aid in the diagnosis of untraceable pain in the oropharyngeal region related to altered PH morphology.

This study aimed to compare the accuracy of 3-dimensional (3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs).

Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test.

The landmarks measured ated.

This study was conducted to evaluate the accuracy of cone-beam computed tomography (CBCT) in detecting the posterior superior alveolar (PSA) artery canal in a sample of the Egyptian population.

CBCT images of 600 maxillary sinuses of patients were examined for the presence or absence of the PSA artery along the lateral wall of the maxillary sinus, and for the diameter and type of the canal in relation to age and sex. The distances from the canal to the alveolar crest and sinus floor were also measured. Each canal was assessed to determine whether it was bifid.

The PSA artery canal could be detected in 92.0% of the sinuses. The mean distance from the inferior border of the PSA artery canal to the sinus floor was 8.2±2.2 mm (range, 3.2-13.6 mm) in males and 7.3±2.1 mm (range, 3.0-13.1 mm) in females. The mean distance from the inferior border of the PSA artery canal to the alveolar crest was 18.2±2.7 mm (range, 11.0-23.9 mm) in males and 17.4±2.3 mm (range, 10.8-23.5 mm) in females. The mean diameter of the PSA artery canal was larger in male subjects. The PSA artery canal was bifid in 8.7% of cases. The most frequently observed location of the PSA artery canal was intraosseous (82.2%).

CBCT was confirmed to be a valuable tool for evaluation and localization of the PSA artery before maxillary sinus lift surgery to avoid intraoperative bleeding.

CBCT was confirmed to be a valuable tool for evaluation and localization of the PSA artery before maxillary sinus lift surgery to avoid intraoperative bleeding.

This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars.

Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05).

The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (

>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat (

<0.05).

Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

This study was performed to investigate mandibular canal displacement in patients with ameloblastoma using a 3-dimensional mirrored-model analysis.

The sample consisted of computed tomographic scans of patients with ameloblastoma (n=10) and healthy controls (n=20). The amount of mandibular canal asymmetry was recorded as a continuous variable, while the buccolingual (yaw) and supero-inferior (pitch) directions of displacement were classified as categorical variables. The t-test for independent samples and the Fisher exact test were used to compare groups in terms of differences between sides and the presence of asymmetric inclinations, respectively (

<0.05).

The length of the mandibular canal was similar on both sides in both groups. The ameloblastoma group presented more lateral (2.40±4.16 mm) and inferior (-1.97±1.92 mm) positions of the mental foramen, and a more buccal (1.09±2.75 mm) position of the middle canal point on the lesion side. Displacement of the mandibular canal tended to be found in the anterior region in patients with ameloblastoma, occurring toward the buccal and inferior directions in 60% and 70% of ameloblastoma patients, respectively.

Mandibular canal displacement due to ameloblastoma could be detected by this superimposed mirrored method, and displacement was more prevalent toward the inferior and buccal directions. This displacement affected the mental foramen position, but did not lead to a change in the length of the mandibular canal. The control group presented no mandibular canal displacement.

Mandibular canal displacement due to ameloblastoma could be detected by this superimposed mirrored method, and displacement was more prevalent toward the inferior and buccal directions. This displacement affected the mental foramen position, but did not lead to a change in the length of the mandibular canal. The control group presented no mandibular canal displacement.

The purpose of this study was to analyze the reliability of 7 panoramic radiographic signs for predicting proximity of the root apices of mandibular third molars to the mandibular canal using cone-beam computed tomography and to correlate these findings with the Pell and Gregory and the Winter classification systems.

An observational, cross-sectional, descriptive study was conducted on 74 patients with bilateral impacted mandibular third molars. Four panoramic radiographic signs were observed in the tooth root (darkening, deflection, and narrowing of the root apices, and bifid apices), and another 3 in the mandibular canal (diversion, narrowing, and interruption of the mandibular canal). Cone-beam computed tomography images were analyzed to identify disruption and diversion of the mandibular canal and root deflection.

Binary logistic regression showed that only 4 of the 7 panoramic radiographic signs were able to predict proximity of the root apices of the mandibular third molars to the mandibular canal darkening of the root, deflection of the root, narrowing of the root, and interruption of the mandibular canal (

<0.05).

Darkening, deflection, and narrowing of the root, in tandem with the interruption of the mandibular canal on panoramic radiographs, indicate that cone-beam computed tomography should be performed when planning the extraction of impacted mandibular third molars. Proximity between mandibular third molars and the mandibular canal is correlated with the Winter classification.

Darkening, deflection, and narrowing of the root, in tandem with the interruption of the mandibular canal on panoramic radiographs, indicate that cone-beam computed tomography should be performed when planning the extraction of impacted mandibular third molars. Proximity between mandibular third molars and the mandibular canal is correlated with the Winter classification.