Gravgaardchapman3306

Z Iurium Wiki

An aptasensor assay for sulfamethazine is introduced based on a gold electrode modified with multi-walled carbon nanotubes@graphene oxide nanoribbons (MWCNTs@GONRs) nanocomposites. The MWCNTs@GONRs nanocomposites were synthesized by a chemical longitudinal partially unzipping method. Its properties are characterized by scanning electron microscope (SEM), energy dispersive spectrometric analysis (EDS), transmission electron microscope (TEM) and X-ray diffraction (XRD). In the presence of sulfamethazine, the conformation of the aptamer changes and a G-quadruplex structure is formed. It inhibits the electron transfer of the redox probe [Fe(CN)6]3-/4- on the electrode surface, causing weakening of the peak current response at the peak potential of 0.17 V (vs. Ag/AgCl). Using differential pulse voltammetry, a linear response was obtained for sulfamethazine concentrations in the range 0.01 ~ 50 ng mL-1 with a detection limit of 5.2 pg mL-1. Graphical abstract Schematic representation of an electrochemical aptasensor for sulfamethazine determination. A gold electrode is modified with multi-walled carbon nanotubes@graphene oxide nanoribbons to improve the electrode performance. When the aptamer binds to sulfamethazine to form G-quadruplex, the peak current response decreases.BACKGROUND The application of minimally invasive surgery (MIS) in advanced gallbladder cancer (GBC) requiring extended cholecystectomy is challenging, in terms of achieving clinically safe and complete oncologic resection. Recently developed robotic systems, however, may provide advantages in overcoming difficulties faced by laparoscopic MIS. The purpose of this study is to investigate the feasibility and advantages of a robotic system to assist with extended cholecystectomy. METHODS Patients diagnosed with clinically suspected stage T2 or above, GBC (as determined by preoperative computed tomography or ultrasonography) underwent robotic extended cholecystectomy (REC) from February 2018 to January 2020. The attached video shows the detailed procedure in the following order the positioning of the patient and the trocars, Kocher maneuver, lymph node dissection (#8, 9, 12, 13), skeletonization of hepatoduodenal ligament, ligation of the cystic duct and liver resection. RESULTS Of 16 patients who underwent REC, mean operation time was 198.3 min and the median estimated blood loss was 295 ml. 11 patients (68.8%) were pathologically diagnosed as stage T2 or above, and the metastatic lymph node was identified in 3 patients (18.8%). All cases had secured tumor-free resection margins, and 3 patients (18.8%) showed invasion to the hepatic parenchyma. The mean number of retrieved lymph nodes was 7.2. The median duration of hospital stay was 7 days. There were no mortality or recurrence within 90 days after the operation. CONCLUSION This study suggests that robotic systems can be safely utilized in advanced stage GBC, facilitating oncologically sufficient lymph node dissection and rapid recovery.BACKGROUND The occurrence of bile duct injury (BDI) during laparoscopic cholecystectomy (LC) is an important medical issue. Expert surgeons prevent intraoperative BDI by identifying four landmarks. The present study aimed to develop a system that outlines these landmarks on endoscopic images in real time. METHODS An intraoperative landmark indication system was constructed using YOLOv3, which is an algorithm for object detection based on deep learning. The training datasets comprised approximately 2000 endoscopic images of the region of Calot's triangle in the gallbladder neck obtained from 76 videos of LC. The YOLOv3 learning model with the training datasets was applied to 23 videos of LC that were not used in training, to evaluate the estimation accuracy of the system to identify four landmarks the cystic duct, common bile duct, lower edge of the left medial liver segment, and Rouviere's sulcus. Additionally, we constructed a prototype and used it in a verification experiment in an operation for a patient with cholelithiasis. Pifithrin-α nmr RESULTS The YOLOv3 learning model was quantitatively and subjectively evaluated in this study. The average precision values for each landmark were as follows common bile duct 0.320, cystic duct 0.074, lower edge of the left medial liver segment 0.314, and Rouviere's sulcus 0.101. The two expert surgeons involved in the annotation confirmed consensus regarding valid indications for each landmark in 22 of the 23 LC videos. In the verification experiment, the use of the intraoperative landmark indication system made the surgical team more aware of the landmarks. CONCLUSIONS Intraoperative landmark indication successfully identified four landmarks during LC, which may help to reduce the incidence of BDI, and thus, increase the safety of LC. The novel system proposed in the present study may prevent BDI during LC in clinical practice.BACKGROUND Strictures are common complications after ileal pouch surgery. The aim of this study is to evaluate the efficacy and safety of endoscopic stricturotomy vs. endoscopic balloon dilation (EBD) in the treatment of pouch inlet strictures. METHODS All consecutive ulcerative colitis patients with the diagnosis of pouch inlet or afferent limb strictures treated in our Interventional Inflammatory Bowel Disease Unit (i-IBD) from 2008 to 2017 were extracted. The primary outcomes were surgery-free survival and post-procedural complications. RESULTS A total of 200 eligible patients were included in this study, with 40 (20.0%) patients treated with endoscopic stricturotomy and 160 (80.0%) patients treated with EBD. Symptom improvement was recorded in 11 (42.3%) patients treated with endoscopic stricturotomy and 16 (13.2%) treated with EBD. Subsequent surgery rate was comparable between the two groups (9 [22.5%] vs. 33 [20.6%], P = 0.80) during a median follow-up of 0.6 years (interquartile range [IQR] 0.4-0.8) vs. 3.6 years (IQR 1.1-6.2) in patients receiving endoscopic stricturotomy and EBD, respectively. The overall surgery-free survival seems to be comparable as well (P = 0.12). None of the patients in the stricturotomy group developed pouch failure, while 9 patients (5.6%) had pouch failure in the balloon dilation group (P = 0.17). Procedural bleeding was seen in three occasions (4.7% per procedure) in patients receiving endoscopic stricturotomy and perforation was seen in three occasions (0.8% per procedure) in patients receiving EBD (P = 0.02). In multivariable analysis, an increased length of the stricture (hazard ratio [HR] 1.4, 95% confidence interval [CI] 1.0-1.8) and concurrent pouchitis (HR 2.5, 95% CI 1.0-5.7) were found to be risk factors for the requirement of surgery. CONCLUSION Endoscopic stricturotomy and EBD were both effective in treating patients with pouch inlet or afferent limb strictures, EBD had a higher perforation risk while endoscopic stricturotomy had a higher bleeding risk.

Autoři článku: Gravgaardchapman3306 (Mejer Qvist)