Finleylunding8932

Z Iurium Wiki

We analyzed the flexural vibration of typical piezoelectric semiconductor plate structures, which provide theoretical guidance for the development of new piezotronic devices.Prestressed concrete (PSC) is widely used for the construction of bridges. The collapse of several bridges with PSC has been reported, and insufficient grout and tendon corrosion were found inside the ducts of these bridges. Therefore, non-destructive testing (NDT) technology is important for identifying defects inside ducts in PSC structures. Electromagnetic (EM) waves have limited detection of internal defects in ducts due to strong reflections from the surface of the steel ducts. Spectral analysis of the existing impact echo (IE) method is limited to specific conditions. Moreover, the flexural mode in upper defects of ducts located at a shallow depth and delamination defects inside ducts are not considered. In this study, the applicability of the elastic wave of IE was analyzed, and multichannel analysis of surface, EM, and shear waves was employed to evaluate six types of PSC structures. A procedure using EM waves, IE, and principal component analysis (PCA) was proposed for a more accurate classification of defect types inside ducts. The proposed procedure was effective in classifying upper, internal, and delamination defects of ducts under 100 mm in thickness, and it could be utilized up to 200 mm in the case of duct defect limitations.Difenacoum (DIF) is one of the most widely used anticoagulant rodenticides. However, accidental or intentional ingestion of DIF seriously threatens humans and other non-target species. Therefore, a rapid and sensitive detection method to quantify DIF is urgently needed. In this study, one anti-DIF nanobody (Nb) was assembled on the surface of a gold interdigitated microelectrode (IDME) using an Au-S bond to fabricate a bioimpedance sensor. To improve the immobilization amount of Nbs on the electrode, a polycrystalline gold IDME was prepared to provide a larger surface and better biocompatibility. Thus, a novel and ultrasensitive bioimpedance sensor based on electrochemical impedance spectroscopy (EIS) was designed for the determination of DIF, and it displayed good reproducibility and stability in human serum. The proposed bioimpedance sensor displayed a wide working range, between 0.1-1000 pg/mL, with a limit of detection (LOD) of 0.1 pg/mL of DIF. This method exhibited excellent performance, good sensitivity, and reproducibility and achieved the highest sensitivity of all currently existing methods used to quantify DIF. The highly sensitive DIF detection of this proposed bioimpedance sensor indicates its potential as an efficacious approach for DIF monitoring in human serum with high accuracy and precision.The stringent demand to develop lightweight materials with enhanced properties suitable for various engineering applications is the focus of this research work. Industrial wastes such as fly ash (FA) and S-glass-fibres (GF) were used as reinforcement materials for high-strength alloy, i.e., Al 7005. Stir casting routes were employed for fabricating the four samples, Al 7005, Al 7005 + 5% GF, Al 7005 + 6% FA and Al 7005 + 5% GF + 6% FA. The extrusion process with different extrusion ratios (ER 5.321, and 2.661) was used to examine the properties of all four samples. click here Extruded samples with ER 5.32 1 resulted in equiaxed grains with refined structure compared to stir casting parts. The effect of the extrusion process and the addition of reinforcements (GF and FA) on the gravimetric, electrochemical, and electrochemical impedance corrosion behaviour of Al 7005 composites in 1M HCl (Hydrochloric acid) solution were investigated. The results of all three corrosion methods showed that Al 7005 + 6% FA exhibited higher corrosion resistance. Corrosion rate of Al 7005, Al 7005 + 5% GF, Al 7005 + 6% FA and Al 7005 + 5% GF + 6% FA is found equal to 3.25, 2.41, 0.34, and 0.76 mpy, respectively. The FA particles remain inert and act as a physical barrier with corrosive media during the corrosion test. GF undergoes fibre degradation or disrupts the continuity of the glass network as a result of fibre leaching, which increases the corrosion rate in the sample. The gravimetric study showed that the corrosion rates decreased with an increase in extrusion ratio, which might be due to corrosion passivation increases and improved properties. The scanning electron microscopy reveals that corrosion fits, flakes and micro-cracks were observed more in the as-cast composites than that of extrusion composites, promoting the corrosion rate.This paper aims to study the radiation shielding characteristics and buildup factor of some types of granite in Egypt. The mass attenuation coefficient (MAC) for three types of granite (gandola, white halayeb, and red aswani) was experimentally determined, and the experimental results were validated by XCOM software. The relative deviation between the two methods does not exceed 3% in all discussed granite samples, which means that MAC calculated through the experimental and XCOM are in suitable agreement. The effective atomic number (Zeff) varies from 13.64 to 10.69, 13.68 to 10.59, and 13.45 and 10.66 for gandola, white halayeb, and red aswani, respectively. As well as the equivalent atomic number (Zeq) was calculated in a wide range of energy to deduce the exposure (EBF) and energy absorption (EABF) buildup factors for the studied granite materials. The linear attenuation coefficient (LAC), half-value layer (HVL), mean free path (MFP) were calculated at each investigated energy and showed that the most effective shielding ability at high energy was red aswani, while at low energy, the shielding ability was nearly constant for studied granites. The present study forms the first endeavor to obtain the radiation shielding properties of the studied materials to be used in practical applications.Silicon carbide (SiC) is the most mature wide band-gap semiconductor and is currently employed for the fabrication of high-efficiency power electronic devices, such as diodes and transistors. In this context, selective doping is one of the key processes needed for the fabrication of these devices. This paper concisely reviews the main selective doping techniques for SiC power devices technology. In particular, due to the low diffusivity of the main impurities in SiC, ion implantation is the method of choice to achieve selective doping of the material. Hence, most of this work is dedicated to illustrating the main features of n-type and p-type ion-implantation doping of SiC and discussing the related issues. As an example, one of the main features of implantation doping is the need for post-implantation annealing processes at high temperatures (above 1500 °C) for electrical activation, thus having a notable morphological and structural impact on the material and, hence, on some device parameters. In this respect, some specific examples elucidating the relevant implications on devices' performances are reported in the paper.

Autoři článku: Finleylunding8932 (Dillon McCormick)