Englishberry3157

Z Iurium Wiki

The addition of surfactant can increase both the probability of pinning and the pinned volume when drops shatter on fat-hen or Teflon. However, the surfactants studied did not substantially improve the probability of pinning on barnyard grass. The difference in behaviour between the two leaf surfaces and the underlying mechanism is worth further study. © 2020 Society of Chemical Industry. © 2020 Society of Chemical Industry.Variations in medical resource usage, both across and within geographical regions, have been widely documented. In this paper, we explore physician practice styles as a possible determinant of these variations. In particular, we exploit patient mobility between physicians to identify practice styles among general practitioners (GPs) in Austria. We use a large administrative data set containing detailed information on a battery of different health-care services and implement a model with additive patient and GP fixed effects that allows flexibly for systematic differences in patients' health states. We find that, although GPs explain only a small part of the overall variation in medical expenses, heterogeneities in spending patterns among GPs are substantial. Conditional on patient characteristics, we document a difference of € 751.47 per patient per year in total medical expenses (which amounts to roughly 45% of the sample mean) between high- and low-spending GPs. © 2020 The Authors. Health Economics published by John Wiley & Sons, Ltd.An unprecedented electrochemical trifluoromethylation/SO2  insertion/cyclization process has been achieved in an undivided cell in an atom-economic fashion. The protocol relies on tandem cyclization of N-cyanamide alkenes by using Langlois' reagent as a source of both CF3 and SO2 under direct anodically oxidative conditions, in which two C-C bonds, two C-X bonds (N-S and S-C), and two rings were formed in a single operation. This transformation enabled efficient construction of various trifluoromethylated cyclic N-sulfonylimines from readily accessible materials. © 2020 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.OBJECTIVES We sought to develop an automatic method for correcting common errors in phasic pressure tracings for physiology-guided interventions on coronary and valvular stenosis. BACKGROUND Effective coronary and valvular interventions rely on accurate hemodynamic assessment. Phasic (subcycle) indexes remain intrinsic to valvular stenosis and are emerging for coronary stenosis. Errors, corrections, and clinical implications of fluid-filled catheter phasic pressure assessments have not been assessed in the current era of ubiquitous, high-fidelity pressure wire sensors. METHODS We recruited patients undergoing invasive coronary physiology assessment. Phasic aortic pressure signals were recorded simultaneously using a fluid-filled guide catheter and 0.014″ pressure wire before and after standard calibration as well as after pullback. We included additional subjects undergoing hemodynamic assessment before and after transcatheter aortic valve implantation. Using the pressure wire as reference standard, we developed an automatic algorithm to match phasic pressures. RESULTS Removing pressure offset and temporal shift produced the largest improvements in root mean square (RMS) error between catheter and pressure wire signals. Alexidine However, further optimization less then 1 mmHg RMS error was possible by accounting for differential gain and the oscillatory behavior of the fluid-filled guide. The impact of correction was larger for subcycle (like systole or diastole) versus whole-cycle metrics, indicating a key role for valvular stenosis and emerging coronary pressure ratios. CONCLUSIONS When calibrating phasic aortic pressure signals using a pressure wire, correction requires these parameters offset, timing, gain, and oscillations (frequency and damping factor). Automatically eliminating common errors may improve some clinical decisions regarding physiology-based intervention. © 2020 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals, Inc.OBJECTIVES This study evaluated the progression of very late in-stent restenosis (VL-ISR) by analyzing four serial coronary angiography (CAG) images and its correlation with neointimal tissue characterization of the VL-ISR lesions on optical coherence tomography (OCT). BACKGROUND Recently, VL-ISR is occasionally observed beyond a few years after drug-eluting stents (DESs) implantation. METHODS This study analyzed 50 VL-ISR lesions after DES in which 4 serial CAGs over a period of 2 years, including at baseline procedure, 9 months after baseline procedure, 12 months before VL-ISR, and at the time of VL-ISR, were performed. Neointimal tissue characteristics by OCT were categorized as homogeneous, heterogeneous with invisible strut (Type I), heterogeneous with visible strut (Type II), speckled (Type III), or heterogeneous with sharply delineated border (Type IV). RESULTS From the development process, 23 VL-ISRs (46%) were categorized as rapid progression and 27 (54%) as gradual progression. The five categories of neointimal tissue composition significantly differed between lesions with rapid and gradual progression. Homogeneous neointima and Type IV heterogeneous neointima were observed only in lesions with gradual progression. Moreover, most Type I heterogeneous neointima was identified in lesions with gradual progression. Instead, main neointimal tissue components of lesions with rapid progression were Type II (43%) and Type III (43%) heterogeneous neointima. CONCLUSION The progression rate of in-stent atherosclerotic changes is gradual, whereas organized thrombus could be associated with an increased risk of rapid neointimal growth. The two types of stenosis progression provide a new insight into the mechanism of VL-ISR development after DES implantation. © 2020 Wiley Periodicals, Inc.The front cover artwork was provided by the group of Prof. Nishino, Tokyo Institute of Technology. The image depicts the investigation of the structure and electron transport of the Au, Ag, Cu, Ni, Fe, and Pd atomic junctions doped with dichloroethylene. Read the full text of the Article at 10.1002/cphc.201900988. © 2020 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

Autoři článku: Englishberry3157 (McGinnis Ellington)