Dixongiles0520

Z Iurium Wiki

In this review, a critical look into the possibility of testing the capacity of natural products to inhibit lipid peroxidation is presented. In vitro systems used to peroxidize a lipid sample are also reviewed on the basis of lipid substrate origin, and, for each of them, procedural insights, oxidation initiation strategies, and lipid peroxidation extent monitoring are discussed.Acquisition of a healthy lifestyle through diet has driven the food manufacturing industry to produce new food products with high nutritional quality. In this sense, consumption of bioactive compounds has been associated with a decreased risk of suffering chronic diseases. Nonetheless, due to their low solubility in aqueous matrices, high instability in food products during processing and preparation as well as poor bioavailability, the use of such compounds is sometimes limited. Recent advancements in encapsulation and protection of bioactive compounds has opened new possibilities for the development of novel food products. In this direction, the present review is attempting to describe encapsulation achievements, with special attention to nanostructured lipid-based delivery systems, i.e., nanoemulsions, multi-layer emulsions and liposomes. Functionality of bioactive compounds is directly associated with their bioavailability, which in turn is governed by several complex processes, including the passage through the gastrointestinal tract and transport to epithelial cells. Therefore, an overview of recent research on the properties of these nanostructured lipid-based delivery systems with a strong impact on the functionality of bioactive compounds will be also provided. Nanostructured lipid-based delivery systems might be used as a potential option to enhance the solubility, stability, absorption and, ultimately, functionality of bioactive compounds. Several studies have been performed in this line, modifying the composition of the nanostructures, such as the lipid-type or surfactants. Overall, influencing factors and strategies to improve the efficacy of encapsulated bioactive compounds within nanostructures have been successfully identified. This knowledge can be used to design effective targeted nanostructured lipid-based delivery systems for bioactive compounds. However, there is still a lack of information on food interactions, toxicity and long-term consumption of such nanostructures.The current climate changes have increased the prevalence and intensity of heat stress (HS) conditions. One of the initial consequences of HS is the impairment of the intestinal epithelial barrier integrity due to hyperthermia and hypoxia following blood repartition, which often results in a leaky gut followed by penetration and transfer of luminal antigens, endotoxins, and pathogenic bacteria. Under extreme conditions, HS may culminate in the onset of "heat stroke", a potential lethal condition if remaining untreated. HS-induced alterations of the gastrointestinal epithelium, which is associated with a leaky gut, are due to cellular oxidative stress, disruption of intestinal integrity, and increased production of pro-inflammatory cytokines. This review summarizes the possible resilience mechanisms based on in vitro and in vivo data and the potential interventions with a group of nutritional supplements, which may increase the resilience to HS-induced intestinal integrity disruption and maintain intestinal homeostasis.GaAs monolithic microwave integrated circuits (MMICs) with different back metallization systems (TiW/Au and Au/Ti/Au) exhibit different problems in the automatic Au-Sn eutectic bonding process, such as edge breakage or excessive voids. In this study, the formation mechanism of the edge breakage and excessive voids were investigated to prevent the damage of the MMICs in mass production scenarios. The microstructure and elemental distribution were studied using a scanning electron microscope and energy-dispersive spectroscopy. check details The void contents of the brazed region were measured with three-dimensional computed tomography. The top Au layer of the TiW/Au metallization partially dissolved in the melting An-Sn solder. Consequently, liquidus temperature of the solder increased, leading to isothermal solidification with the formation of ζ-Au5Sn in the scrubbing process, which was the reason for the edge breakage. The terminal Au film of the Au/Ti/Au metallization completely dissolved in the melting An-Sn solder. The metallurgical combination was achieved by the formation of the TiAu4 intermetallic compound between the Au-Sn solder and the Ti layer. The wettability of Au-Sn solder on Ti layer should be improved to prevent the formation of the excessive voids.Optical projection tomography (OPT) is the direct optical equivalent of X-ray computed tomography (CT). To obtain a larger depth of field, traditional OPT usually decreases the numerical aperture (NA) of the objective lens to decrease the resolution of the image. So, there is a trade-off between sample size and resolution. Commercial microfluidic systems can observe a sample in flow mode. In this paper, an OPT instrument is constructed to observe samples. The OPT instrument is combined with commercial microfluidic systems to obtain a three-dimensional and time (3D + T)/four-dimensional (4D) video of the sample. "Focal plane scanning" is also used to increase the images' depth of field. A series of two-dimensional (2D) images in different focal planes was observed and compared with images simulated using our program. Our work dynamically monitors 3D OPT images. Commercial microfluidic systems simulate blood flow, which has potential application in blood monitoring and intelligent drug delivery platforms. We design an OPT adaptor to perform OPT on a commercial wide-field inverted microscope (Olympusix81). Images in different focal planes are observed and analyzed. Using a commercial microfluidic system, a video is also acquired to record motion pictures of samples at different flow rates. To our knowledge, this is the first time an OPT setup has been combined with a microfluidic system.We present a numerical model for the recently introduced simple and inexpensive micromachined aluminum devices with a polydimethylsiloxane (PDMS) cover for microparticle acoustophoresis. We validate the model experimentally for a basic design, where a microchannel is milled into the surface of an aluminum substrate, sealed with a PDMS cover, and driven at MHz frequencies by a piezoelectric lead-zirconate-titanate (PZT) transducer. Both experimentally and numerically we find that the soft PDMS cover suppresses the Rayleigh streaming rolls in the bulk. However, due to the low transverse speed of sound in PDMS, such devices are prone to exhibit acoustic streaming vortices in the corners with a relatively large velocity. We predict numerically that in devices, where the microchannel is milled all the way through the aluminum substrate and sealed with a PDMS cover on both the top and bottom, the Rayleigh streaming is suppressed in the bulk thus enabling focusing of sub-micrometer-sized particles.

Autoři článku: Dixongiles0520 (Lunde Noonan)