Colelyhne6855

Z Iurium Wiki

Image registration and alignment are the main limitations of augmented reality-based knee replacement surgery. This research aims to decrease the registration error, eliminate outcomes that are trapped in local minima to improve the alignment problems, handle the occlusion and maximize the overlapping parts.

markerless image registration method was used for Augmented reality-based knee replacement surgery to guide and visualize the surgical operation. While weight least square algorithm was used to enhance stereo camera-based tracking by filling border occlusion in right to left direction and non-border occlusion from left to right direction.

This study has improved video precision to 0.57 mm ∼ 0.61 mm alignment error. Furthermore, with the use of bidirectional points, i.e. Forwards and backwards directional cloud point, the iteration on image registration was decreased. This has led to improved the processing time as well. The processing time of video frames was improved to 7.4 ∼11.74 fps.

It seems cThe proposed augmented reality system helps in accurate visualization and navigation of anatomy of knee such as femur, tibia, cartilage, blood vessels, etc. This article is protected by copyright. All rights reserved.The construction of advanced micro-supercapacitors (MSCs) with both wide working-voltage and high energy density is promising but still challenging. In this work, a series of nitrogen-doped, cross-coupled micro-mesoporous carbon-metal networks (N-STC/Mx Oy ) is developed as robust additives to 3D printing inks for MSCs fabrication. Taking the N-STC/Fe2 O3 nanocomposite as an example, both experimental results and theoretical simulations reveal that the well-developed hierarchical networks with abundantly decorated ultrafine Fe2 O3 nanoparticles not only significantly facilitate the ion adsorption at its three-phase boundaries (Fe2 O3 , N-STC, and electrolyte), but also greatly favor ionic diffusion/transport with shortened pathways. Consequently, the as-prepared N-STC/Fe2 O3 electrode delivers a high gravimetric capacitance (267 F g-1 at 2 mV s-1 ) and outstanding stability in a liquid-electrolyte-based symmetric device, as well as a record-high energy density of 114 Wh kg-1 for an asymmetric supercapacitor. PT2399 order Particularly, the gravimetric capacitance of the ionogel-based quasi-solid-state MSCs by 3D printing reaches 377 F g-1 and the device can operate under a wide temperature range (-10 to 60 °C).

Some difficulties are common when using endoscopes. Steering is not intuitive, the endoscope weight is a physical burden to physicians and communication problems often occur between operators.

To overcome these, we developed a robotic endoscopy system and conducted a usability test to compare conventional and robotic manipulation. Nine novices and eighteen physicians participated with the physicians being divided into intermediate and expert groups. The participants performed endoscope insertion into a simulator (physicians) or lesion marking on a testbed (novices) and simulate biopsies.

Novices completed the tasks faster and with a lower workload when using robotic manipulation, whereas the experts showed the opposite trend. Still, the intermediates showed no significant difference as trials proceeded. Nevertheless, the learning curve analysis showed that the learning rate in all groups is greater for robotic manipulation (21.02% on average) than for conventional manipulation (13.75%) and predicted that physicians can reach manual performance.

The proposed robotic endoscopy system may allow solo-manipulation using one controller and may be more intuitive and convenient to use than conventional manipulation.

The proposed robotic endoscopy system may allow solo-manipulation using one controller and may be more intuitive and convenient to use than conventional manipulation.MicroRNAs (miRNAs), a class of small, noncoding RNA molecules represent important regulators of gene expression. Recent reports have implicated their role in the cell specification process acting as "fine-tuners" to ensure the precise gene expression at the specific stage of cell differentiation. Here, we used retinal organoids differentiated from human pluripotent stem cells (hPSCs) as a model to closely investigate the role of a sensory organ-specific and evolutionary conserved miR-183/96/182 cluster. Using a miRNA tough decoy approach, we inhibited the miR-183/96/182 cluster in hPSCs. Inhibition of the miRNA cluster resulted in an increased expansion of neuroepithelium leading to abnormal "bulged" neural retina in organoids, associated with upregulation of neural-specific and retinal-specific genes. Importantly, we identified PAX6, a well-known essential gene in neuroectoderm specification, as a target of the miR-183/96/182 cluster members. Taken together, the miR-183/96/182 cluster not only represents an important regulator of PAX6 expression, but it also plays a crucial role in retinal tissue morphogenesis.Highly accelerated real-time cine MRI using compressed sensing (CS) is a promising approach to achieve high spatio-temporal resolution and clinically acceptable image quality in patients with arrhythmia and/or dyspnea. However, its lengthy image reconstruction time may hinder its clinical translation. The purpose of this study was to develop a neural network for reconstruction of non-Cartesian real-time cine MRI k-space data faster ( less then 1 min per slice with 80 frames) than graphics processing unit (GPU)-accelerated CS reconstruction, without significant loss in image quality or accuracy in left ventricular (LV) functional parameters. We introduce a perceptual complex neural network (PCNN) that trains on complex-valued MRI signal and incorporates a perceptual loss term to suppress incoherent image details. This PCNN was trained and tested with multi-slice, multi-phase, cine images from 40 patients (20 for training, 20 for testing), where the zero-filled images were used as input and the corresponding CSPCNN is capable of rapid reconstruction (25 s per slice with 80 frames) of non-Cartesian real-time cine MRI k-space data, without significant loss in image quality or accuracy in LV functional parameters.

Autoři článku: Colelyhne6855 (McGuire Gravesen)