Callesenmathiesen2988

Z Iurium Wiki

INTRODUCTION The challenging environment of prehospital casualty care demands providers to make prompt decisions and to engage in lifesaving interventions, occasionally without them being adequately experienced. Telementoring based on augmented reality (AR) devices has the potential to decrease the decision time and minimise the distance gap between an experienced consultant and the first responder. The purpose of this study was to determine whether telementoring with AR glasses would affect chest thoracotomy performance and self-confidence of inexperienced trainees. METHODS Two groups of inexperienced medical students performed a chest thoracotomy in an ex vivo pig model. While one group was mentored remotely using HoloLens AR glasses, the second performed the procedure independently. An observer assessed the trainees' performance. In addition, trainees and mentors evaluated their own performance. RESULTS Quality of performance was found to be superior with remote guidance, without significant prolongation of the procedure (492 s vs 496 s, p=0.943). Moreover, sense of self-confidence among participant was substantially improved in the telementoring group in which 100% of the participants believed the procedure was successful compared with 40% in the control group (p=0.035). CONCLUSION AR devices may have a role in future prehospital telementoring systems, to provide accessible consultation for first responders, and could thus positively affect the provider's confidence in decision-making, enhance procedure performance and ultimately improve patient prognosis. That being said, future studies are required to estimate full potential of this technology and additional adjustments are necessary for maximal optimisation and implementation in the field of prehospital care. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.INTRODUCTION The objective was to report on the experience of the French Army Health Service in the management of blast injury of the hands related to warfare explosive devices. METHODS A retrospective study was conducted in the Percy Military Hospital (role 4 medical treatment facility) among French soldiers who presented with a combat-related blast injury of the hand between 2002 and 2018. The functional result was assessed by the disabilities of the arm, shoulder and hand (DASH) and the Orthotics and Prosthetics User Survey (OPUS, upper extremity functional status) scores. Proximal amputations (PAs) and distal amputations (DAs) were distinguished for the analysis. RESULTS Fifteen patients with a mean age of 31±8 years were included. They totalised 20 blasted hands. There were 16 traumatic amputations 8 in each of the PA and DA groups. Twelve patients had additional injuries, four of which were polytraumatic. Skin closure time and flap use were higher in the DA group. Only one thumb reconstruction was performed. At a mean follow-up of 6.5±4 years, the number of amputees wearing a prosthesis was higher in the PA group. The mean DASH and OPUS scores were 35.5%±24.0% and 64.0%±19.0%, respectively, with no difference between the two groups. CONCLUSION The severity of hand blasts related to warfare explosive devices requires the systematic application of damage control surgery. PAs are frequent and secondary reconstruction options are limited. The functional result is poor and similar between proximal and distal amputees. © Author(s) (or their employer(s)) 2020. No commercial re-use. https://www.selleckchem.com/products/Vorinostat-saha.html See rights and permissions. Published by BMJ.Recent uses of nerve agents underline the need of early diagnosis as trigger to react (initiating medical countermeasures, avoiding cross-contamination). As organophosphorus (OP) pesticide poisoning exerts the same pathomechanism, that is, inhibition of the pivotal enzyme acetylcholinesterase (AChE), a portable cholinesterase (ChE) test kit was applied in an emergency room for rapid diagnosis of OP poisoning. OP nerve agents or pesticides result in the inhibition of AChE. As AChE is also expressed on erythrocytes, patient samples are easily available. However, in most clinics only determination of plasma butyrylcholinesterase (BChE) is established which lacks a pathophysiological correlate, shows higher variability in the population and behaves different regarding inhibition by OP and reactivation by oximes. The ChE test kit helped to diagnose atypical cases of OP poisoning, for example, missing of typical muscarinic symptoms, and resulted in administration of pralidoxime, the oxime used in Serbia. The ChE test kit also allows an initial assessment whether an oxime therapy is successful. In one case report, AChE activity increased after oxime administration indicating therapeutic success whereas BChE activity did not. With only BChE at hand, this therapeutic effect would have been missed. As inhibition of AChE or BChE activity is determined, the CE-certified device is a global diagnostic tool for all ChE inhibitors including carbamates which might also be misused as chemical weapon. The ChE test kit is a helpful point-of-care device for the diagnosis of ChE inhibitor poisoning. Its small size and easy menu-driven use advocate procurement where nerve agent and OP pesticide exposure are possible. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.INTRODUCTION Severe haemorrhage from the arm that is unresponsive to direct pressure necessitates the application of a tourniquet. Detachable arm protection, referred to as brassards, are used by the UK Armed Forces to protect the upper arm from fragmentation threats. However, the coverage they originally provided was based on limited medical evidence. Medical consensus has determined that the dimensions of arm protection should in future be related to how far up the arm a tourniquet can be applied. METHOD CT scans of 120 male Armed Forces personnel were analysed to ascertain the vertical distances from acromion process to the point at which a tourniquet can applied, equating to the anterior axillary fold. These values were statistically compared with those derived from the 2007 UK Military anthropometric survey using a paired t-test. Additional distances were added to account for tourniquet width and slippage, with the total value compared with VIRTUS brassard length. RESULTS No significant difference (p less then 0.

Autoři článku: Callesenmathiesen2988 (Tyson McDougall)