This study investigated the accuracy of the HeartWare HVAD flow estimator for left ventricular assist device (LVAD) support and biventricular assist device (BiVAD) support for modes of reduced speed (BiVAD-RS) and banded outflow (BiVAD-B). The HVAD flow estimator was evaluated in a mock circulatory loop under changes in systemic and pulmonary vascular resistance, heart rate, central venous pressure, and simulated hematocrit (correlated to viscosity). A difference was found between mean estimated and mean measured flow for LVAD (0.1 ± 0.3 L/min), BiVAD-RS (-0.1 ± 0.2 L/min), and BiVAD-B (0 ± 0.2 L/min). Analysis of the flow waveform pulsatility showed good correlation for LVAD (r2 = 0.98) with a modest spread in error (0.7 ± 0.1 L/min), while BiVAD-RS and BiVAD-B showed similar spread in error (0.7 ± 0.3 and 0.7 ± 0.2 L/min, respectively), with much lower correlation (r2 = 0.85 and r2 = 0.60, respectively). This study demonstrated that the mean flow error of the HVAD flow estimator is similar when the device is used in LVAD, BiVAD-RS, or BiVAD-B configuration. However, the instantaneous flow waveform should be interpreted with caution, particularly in the cases of BiVAD support.The preferred assay for measuring and adjusting unfractionated heparin (UFH) infusion to achieve optimal outcomes during extracorporeal membrane oxygenation (ECMO) is not well established. This retrospective cohort study explored safety and efficacy outcome differences between anti-factor Xa (anti-Xa) and activated partial thromboplastin time (aPTT) for UFH in adult venoarterial ECMO. Forty-one patients were included and analyzed. The UFH rate at first goal and time to goal were both higher in the aPTT versus anti-Xa cohort but did not achieve statistical significance (12.14 vs. 9.58 unit/kg/hour (p = 0.29), 20.22 vs. 12.05 hours (p = 0.11)). The aPTT cohort was in target goals 35.0% of the time versus 47.7% in the anti-Xa cohort (p = 0.13), above goal 41.0% vs. 17.3% (p = 0.02), and below-goal 24.0% versus 35.0% of the time (p = 0.34). Minimum heparin rates in the aPTT cohort were 6.28 vs. 3.33 unit/kg/hour in the anti-Xa cohort (p = 0.07), and the maximum UFH rate was 18.77 unit/kg/hour vs. 15.48 unit/kg/hour (p = 0.10). Our findings suggest that aPTT monitoring may result in a delay to target attainment, higher UFH rates, and overall exposure.A subset of patients with coronavirus disease 2019 (COVID-19) develop profound respiratory failure and are treated via invasive mechanical ventilation (IMV). Of these, a smaller subset has severe gas exchange abnormalities that are refractory to maximal levels of IMV support. Extracorporeal membrane oxygenation (ECMO) has been used successfully in these circumstances. However, using ECMO only after failure of IMV exposes patients to the risks of ventilator-induced lung injury. Selleckchem 5-Chloro-2'-deoxyuridine We report a successful outcome using ECMO in the setting of COVID-19 in the absence of IMV failure in an awake, nonintubated patient. This approach may be beneficial for selected patients with COVID-19.

To compare the sagittal height (SH) measurements and best fit sphere (BFS) scleral curvature obtained with two different diagnostic technologies.

Prospective, nonrandomized, and comparative study analyzing 23 healthy eyes of 23 patients (age, 14-52 years) was conducted. A complete eye examination was performed including a corneoscleral topographic analysis with the Scheimpflug camera-based system Pentacam (Oculus GmbH, Wetzlar, Germany) and afterward with the Fourier domain profilometer Eye Surface Profiler (ESP) (Eaglet-Eye, Houten, the Netherlands). Differences between devices in temporal SH (TSH), nasal SH (NSH), and mean SH (MSH) measurements at 13- and 15-mm chord length and in scleral BFS were analyzed.

Statistically significant differences were found in TSH, NSH, and MSH obtained with Pentacam and ESP (P≤0.017), with a range of agreement from 0.21 to 1.28 mm, and a clear trend of the Pentacam system to provide higher SH measurements. Significant differences were found between Pentacam scleral BFS and ESP outer BFS (P<0.001) (range agreement, 3.57 mm). Significant correlations were found between spherical equivalent and differences between devices in 15-mm TSH (r=0.485; P=0.048), as well as between the difference between devices for some SH measurements and the magnitude of such SH values (r≥0.504; P≤0.014).

Sagittal height and scleral BFS measurements obtained with the two devices are not interchangeable, with an increased difference in SH measures between devices in eyes with less myopic refractive error and increased SH values.

Sagittal height and scleral BFS measurements obtained with the two devices are not interchangeable, with an increased difference in SH measures between devices in eyes with less myopic refractive error and increased SH values.

To investigate underlying diagnoses and outcomes of patients undergoing Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) treatment at the first Canadian PROSE center.

A retrospective chart review was conducted on patients referred for PROSE treatment and fitted with PROSE devices from 2018 to 2020. Data were collected on diagnoses, presenting symptoms, previous lens modalities attempted, best-corrected visual acuities (BCVAs) pre-PROSE and post-PROSE, daily wear time, and failure rates. Best-corrected visual acuities pre-PROSE and post-PROSE were compared to evaluate visual improvement.

In total, 78 patients (126 eyes) were analyzed. The most common diagnoses were keratoconus (n=39 eyes) and postcorneal graft (n=15) in the distorted cornea group, and limbal stem cell deficiency (n=17) and graft versus host disease (n=15) in the ocular surface disease (OSD) group. Most frequent symptoms included blur, photophobia, and pain. Most common lens modalities attempted pre-PROSE were conventional scleral lenses and glasses. The overall mean BCVA improvement was 0.40 logarithm of the minimal angle of resolution (logMAR) (4-lines Snellen) (P<0.0001). Best-corrected visual acuities improvement in the distorted cornea group (0.52 logMAR, 5-lines) was significantly greater than in the OSD group (0.29 logMAR, 3-lines) (P=0.004).

Prosthetic replacement of the ocular surface ecosystem treatment can provide significant visual improvement for patients with distorted corneal surfaces and OSDs who failed other lens modalities.

Prosthetic replacement of the ocular surface ecosystem treatment can provide significant visual improvement for patients with distorted corneal surfaces and OSDs who failed other lens modalities.We report a case of familial dementia having some clinical features characteristic of dementia with Lewy bodies, in which a novel mutation Ala275Ser within the presenilin-1 (PSEN1) gene was identified. We review the association of PSEN1 mutation with dementia with Lewy bodies features, noting this to be an uncommonly reported observation.

The aim was to identify whether performance on olfactory identification can distinguish neurological/neurodegenerative disorders (NNDs) from primary psychiatric disorders (PPDs).

This is a cross-sectional retrospective study of inpatients assessed in Neuropsychiatry, Royal Melbourne Hospital. Data extracted from the admission records included demographics, tobacco use, medical comorbidities, cognitive function using the Neuropsychiatry Unit Cognitive Assessment Tool (NUCOG), and odor identification using the Sniffin' Sticks Screening 12 test. The final diagnosis for patients was informed by established diagnostic criteria.

A total 121 patients were included. Eighty-eight patients (73%) were diagnosed with neurological or neurodegenerative disease, including Alzheimers dementia, frontotemporal dementia, Lewy body parkinsonian-related dementias (Parkinson disease, multiple system atrophy, dementia with Lewy bodies) and other neurological causes of dementia; 33 patients (27%) were diagnosed with PPDs (including mood and psychotic disorders). Patients who scored ≤8 on the Sniffin' Sticks Screening 12 test were more likely to have NND than PPD, even after adjustment for age, sex and tobacco use (P=0.009, adjusted odds ratios=3.85, 95% confidence interval=1.40-10.62). Receiver operating characteristic curve analyses demonstrated that a score of ≤8 differentiated NND from PPD with sensitivity of 57% and specificity of 73% (receiver operating characteristic area under the curve of 0.67, P=0.004).

Patients with neuropsychiatric difficulties who score 8 or less on Sniffin' Sticks are more likely to have a neurodegenerative illness. A cut-off score of 8 is potentially a "red flag" for clinicians faced with the diagnostic question of PPD versus NND.

Patients with neuropsychiatric difficulties who score 8 or less on Sniffin' Sticks are more likely to have a neurodegenerative illness. A cut-off score of 8 is potentially a "red flag" for clinicians faced with the diagnostic question of PPD versus NND.

To describe factors associated with driving history, habits, and self-reported driving difficulties of 1982 older adults in a population-based survey.

This was a community setting.

Age-stratified random population sample drawn from publicly available voter registration list.

Participants underwent assessments including cognitive testing and self-reported current and past driving status, instrumental activities of daily living, self-rated health, social supports, physical limitations, and depressive symptoms. We built multivariable logistic regression models to identify factors associated with never having driven, having ceased driving, and reporting difficulties while driving.

In the multivariable model, "never drivers" were more likely than "ever drivers" to be older, female, less educated and to leave home less frequently. Former drivers were significantly older, more likely to be women, have lower test performance in the cognitive domain of attention, have more instrumental activity of daily livipatients and families on driving safety.

Alzheimer disease (AD) is a progressive and complex neurodegenerative disease. Approximately 70% of AD risk is attributed to genetic risk factors, including variants in amyloid precursor protein (APP), presenilin 1 (PSEN1), and presenilin 2 (PSEN2) genes. Several studies have revealed a considerable number of candidate loci and genes for AD among different ethnic populations. However, the outcomes of these studies have been inconsistent. In this study, we aimed to investigate the spectrum of variants that are associated with the onset and development of AD among 22 Arab countries.

We systematically searched 4 literature databases (Science Direct, Scopus, PubMed, and Web of Science) from the date of inception until July 2020 using various search terms to obtain all the reported genetic data on Arab AD cases.

In total, 18 studies were included, comprising a total of 2173 individuals, of whom 888 were clinically diagnosed AD patients and were genetically tested for genes and variants associated with AD. A total of 27 variants in 8 genes were found to be associated with AD. Of these variants, 17 were unique to the Arab population and 10 were shared with other ethnic groups.

There is a dearth of studies on the genetics of AD in the Arab world. There seems to be distinctive genetic and clinical susceptibility profiles for Arab patients with AD.

There is a dearth of studies on the genetics of AD in the Arab world. There seems to be distinctive genetic and clinical susceptibility profiles for Arab patients with AD.

Autoři článku: Bundgaardchappell4810 (Temple Power)