Lundgrenmunoz2950

Z Iurium Wiki

Coronary obstruction, a rare complication of transcatheter aortic valve replacement, can be fatal. Few data exist on this phenomenon, and, to date, authors have reported only single coronary lesions. We present a case in which 2 coronary arteries obstructed immediately after transapical transcatheter aortic valve replacement. The patient was an 81-year-old woman with symptomatic severe aortic stenosis who underwent transapical transcatheter aortic valve replacement. Immediately after an Edwards Sapien XT valve was deployed, she experienced sudden cardiogenic shock resulting from obstruction of the left main coronary artery ostium and the distal left anterior descending coronary artery. The left main obstruction was caused by direct compression from a large calcified mass and the valve frame. The left anterior descending coronary artery obstruction was caused by ambient myocardial tightening and external compression around the apical sutures. Revascularization was achieved through coronary stent placement and suture removal, respectively. Our patient's case highlights the risk for coronary obstructions after transapical transcatheter aortic valve replacement, and we discuss how they can be managed. © 2020 by the Texas Heart® Institute, Houston.Improved management of interrupted aortic arch has increased long-term survival rates. Longer life expectancies in neonates and children surgically treated for interrupted aortic arch may necessitate complex reinterventions when sequelae develop in adulthood. We report the case of a 24-year-old man who had undergone initial repair of interrupted aortic arch type B at one week and reintervention at 6 years of age. He presented with a 5.5 × 9-cm pseudoaneurysm of the proximal descending thoracic aorta. He underwent surgical replacement of his distal aortic arch and proximal descending thoracic aorta, with a bypass to his left subclavian artery. In addition to our patient's case, we discuss considerations in treating recipients of early interrupted aortic arch repairs as they live longer and undergo multiple reinterventions. © 2020 by the Texas Heart® Institute, Houston.The number of procedures for upgrading implantable devices for cardiac resynchronization therapy has increased considerably during the last decade. A major challenge that operators face in these circumstances is occlusion of the access vein. We have modified a pull-through method to overcome this obstacle. Six consecutive patients with occluded access veins and well-developed collateral networks underwent a procedure in which the occluded vein was recanalized by snaring the existing atrial lead via transfemoral access. Upgrading the device was successful in all patients; none had intraprocedural complications. Our experience shows that our modified pull-through technique may be a feasible alternative for upgrading cardiac resynchronization therapy in patients with venous occlusion. © 2020 by the Texas Heart® Institute, Houston.Surgery for complex congenitally corrected transposed great arteries is one of the greatest challenges in cardiovascular surgery. We report our experience with bidirectional Glenn shunt placement as a palliative procedure for complex congenitally corrected transposition. We retrospectively identified 50 consecutive patients who had been diagnosed with congenitally corrected transposition accompanied by left ventricular outflow tract obstruction and ventricular septal defect and who had then undergone palliative bidirectional Glenn shunt placement at our institution from January 2005 through December 2014. Patients were divided into 3 groups according to subsequent surgeries Fontan completion (total cavopulmonary connection, 13 patients) (group 1), anatomic repair (hemi-Mustard and Rastelli procedures without Glenn takedown, 11 patients) (group 2), and prolonged palliation (no further surgery, 26 patients) (group 3). After shunt placement, no patient died or had ventricular dysfunction. Overall, mean oxygen saturation increased significantly from 79.5% ± 13.5% preoperatively to 94.1% ± 7.3% (P less then 0.001). The median time from shunt placement to Fontan completion and anatomic repair, respectively, was 2.1 years (range, 1.6-5.2 yr) and 1.1 years (range, 0.6-2.4 yr). Only 2 late deaths occurred, both in group 1. In group 3, time from shunt placement to latest follow-up was 4.5 years (range, 2.3-8 yr). At latest follow-up, mean oxygen saturation was 91.6% ± 10.3%, and no patients had impaired ventricular function. Bidirectional Glenn shunt placement as an optional palliative procedure for complex congenitally corrected transposition has favorable outcomes. Later, patients can feasibly be treated by Fontan completion or anatomic repair. Use of a bidirectional Glenn shunt for open-ended palliation is also acceptable. © 2020 by the Texas Heart® Institute, Houston.The 6-minute walk distance (6MWD) test is a useful prognostic tool in chronic heart failure. Its usefulness after percutaneous coronary intervention is unknown. In a prospective observational study, patients underwent a 6MWD test within 2 weeks after percutaneous coronary intervention. The primary endpoint was major adverse cardiovascular events (MACE) (death, acute coronary syndrome, and heart failure admission) at one year. Apamin datasheet Receiver operating characteristic curves and area under the curve were used to determine the 6MWD test's predictive power, and the Youden index was used to measure its effectiveness. A total of 212 patients were enrolled (98% men; mean age, 65 ± 9 yr). Major comorbidities were hypertension in 187 patients (88%), dyslipidemia in 186 (88%), and diabetes mellitus in 95 (45%). Among the 176 patients (83%) who completed the 6MWD test, the incidence of MACE at one year was 22% (acute coronary syndrome in 17%; heart failure admission in 4%; and death in 3%). The area under the curve for MACE was 0.59, and 6MWD was shorter for patients with MACE than for those without (290 vs 326 m; P=0.03). For 39 patients with previous heart failure who completed the 6MWD test, the area under the curve was 0.64 for MACE and 0.78 for heart failure admission. The 6MWD test predicted reasonably well the incidence of MACE one year after percutaneous coronary intervention. In a subgroup of patients with previous heart failure, it fared even better in predicting heart failure admission. Larger studies are needed to confirm these findings. © 2020 by the Texas Heart® Institute, Houston.We evaluated whether an irrigated contact force-sensing catheter would improve the safety and effectiveness of radiofrequency ablation of premature ventricular contractions originating from the right ventricular outflow tract. We retrospectively reviewed the charts of patients with symptomatic premature ventricular contractions who underwent ablation with a contact force-sensing catheter (56 patients, SmartTouch) or conventional catheter (59 patients, ThermoCool) at our hospital from August 2013 through December 2015. During a mean follow-up of 16 ± 5 months, 3 patients in the conventional group had recurrences, compared with none in the contact force group. Complications occurred only in the conventional group (one steam pop; 2 ablations suspended because of significantly increasing impedance). In the contact force group, the median contact force during ablation was 10 g (interquartile range, 7-14 g). Times for overall procedure (36.9 ± 5 min), fluoroscopy (86.3 ± 22.7 s), and ablation (60.3 ± 21.4 s) were significantly shorter in the contact force group than in the conventional group (46.2 ± 6.2 min, 107.7 ± 30 s, and 88.7 ± 32.3 s, respectively; P less then 0.001). In the contact force group, cases with a force-time integral less then 560 gram-seconds (g-s) had significantly longer procedure and fluoroscopy times (both P less then 0.001) than did those with a force-time integral ≥560 g-s. These findings suggest that ablation of premature ventricular contractions originating from the right ventricular outflow tract with an irrigated contact force-sensing catheter instead of a conventional catheter shortens overall procedure, fluoroscopy, and ablation times without increasing risk of recurrence or complications. © 2020 by the Texas Heart® Institute, Houston.This study is aimed at investigating the effects of shikonin, a pyruvate kinase M2 (PKM2) inhibitor, on the functions of myeloid dendritic cells (mDCs) in a mouse model of severe aplastic anemia (AA) generated by total body irradiation and lymphocyte infusion. Flow cytometry and qPCR were used to determine the proportions of PKM2+ mDCs and other immune indicators in the AA mice. Glucose consumption level, pyruvate generation level, and ATP content were used to determine the level of glycolytic metabolism in the mDCs. The survival rates of AA mice were evaluated after the administration of shikonin or the immunosuppressive agent cyclosporin A. The AA mice displayed pancytopenia, decreased CD4+/CD8+ cell ratio, increased perforin and granzyme levels in CD8+ cells, increased costimulatory CD80 and CD86 expressions, and inadequate regulatory T cell number. In vivo animal experiments showed that the shikonin-mediated inhibition of the PKM2 expression in mice was associated with high survival rates. In addition, the administration of cyclosporin A or shikonin decreased the expression of cytotoxic molecules and costimulatory CD80 and CD86 on CD8+ cells. Taken together, the results of this study indicated that shikonin could inhibit the activation and proliferation of mDCs as well as the activation of downstream cytotoxic T cells by reducing the PKM2 level in mDCs. Copyright © 2020 Mengying Zheng et al.We investigated activation status, cytotoxic potential, and gut homing ability of the peripheral blood Natural Killer (NK) cells in Crohn disease (CD) patients. For this purpose, we compared the expression of different activating and inhibitory receptors (KIR and non-KIR) and integrins on NK cells as well as their recent degranulation history between the patients and age-matched healthy controls. The study was conducted using freshly obtained peripheral blood samples from the study participants. Multiple color flow cytometry was used for these determinations. Our results show that NK cells from treatment-naïve CD patients expressed higher levels of activating KIR as well as other non-KIR activating receptors vis-à-vis healthy controls. They also showed increased frequencies of the cells expressing these receptors. The expression of several KIR and non-KIR inhibitory receptors tended to decrease compared with the cells from healthy donors. NK cells from the patients also expressed increased levels of different gut-homing integrin molecules and showed a history of increased recent degranulation events both constitutively and in response to their in vitro stimulation. Furthermore, treatment of the patients tended to reverse these NK cell changes. Our results demonstrate unequivocally, for the first time, that peripheral blood NK cells in treatment-naïve CD patients are more activated and are more poised to migrate to the gut compared to their counterpart cells from healthy individuals. Moreover, they show that treatment of the patients tends to normalize their NK cells. The results suggest that NK cells are very likely to play a role in the immunopathogenesis of Crohn disease. Copyright © 2020 Suzanne Samarani et al.

Autoři článku: Lundgrenmunoz2950 (Blair Bidstrup)