We report here validation of the Immulite 2000 Xpi cortisol immunoassay (Siemens; with kit lot numbers less then 550) for measurement of urine cortisol in dogs, with characterization of the precision (CV), accuracy (spiking-recovery [SR] bias), and observed total error (TEo = bias + 2CV) across the reportable range. Linearity assessed by simple linear regression was excellent. Imprecision, SR bias, and TEo increased markedly with decreasing urine cortisol concentration. Interlaboratory comparison studies determined range-based (RB) bias and average bias (AB). The 3 biases (SR, RB, and AB) and resulting TEo differed markedly. At 38.6 and 552 nmol/L (1.4 and 20 μg/dL), between-run CVs were 10% and 4.5%, respectively, and TEoRB were ~30% and 20%, respectively, similar to observations in serum in another validation study. These analytical performance parameters should be considered for urine cortisolcreatinine ratio (UCCR) result interpretation, given that, for any hypothetical errorless urine creatinine measurement, the error % on UCCR mirrors the error % on urine cortisol. Importantly, there is no commonly used interpretation threshold for UCCR, given that UCCR varies greatly depending on measurement methods and threshold computation. To date, there is no manufacturer-provided quality control material (QCM) with target values for urine cortisol with an Immulite; for Liquicheck QCM (Bio-Rad), between-run imprecision was ~5% for both QCM levels. Acceptable QC rules are heavily dependent on the desired total allowable error (TEa) for the QCM system, itself limited by the desired clinical TEa.

Early extubation is performed either in the operating room or in the cardiovascular intensive care unit during the first 24 postoperative hours; however, altitude might possibly affect the process. The aim of this study is the evaluation of early extubation feasibility of patients undergoing congenital heart surgery in a center located at 2,691 m (8,828 ft.) above sea level.

Patients undergoing congenital heart surgery, from August 2012 through December 2018, were considered for early extubation. The following variables were recorded weight, serum lactate, presence or not of Down syndrome, optimal oxygenation and acid-base status according to individual physiological condition (biventricular or univentricular), age, bypass time, and ventricular function. Standardized anesthetic management with dexmedetomidine-fentanyl-rocuronium and sevoflurane was used. If extubation in the operating room was considered, 0.08 mL/kg of 0.5% ropivacaine was injected into the parasternal intercostal spaces bilaterally before closing the sternum.

Four hundred seventy-eight patients were operated and 81% were early extubated. Mean pre- and postoperative SaO

was 92% and 98%; postoperative SaO

for Glenn and Fontan procedures patients was 82% and 91%, respectively. Seventy-three percent of patients who underwent Glenn procedure, 89% of those who underwent Fontan procedure (all nonfenestrated), and 85% with Down syndrome were extubated in the operating room. Reintubation rate in early extubated patients was 3.6%.

Early extubation is feasible, with low reintubation rates, at 2,691 m (8,828 ft.) above sea level, even in patients with single ventricle physiology.

Early extubation is feasible, with low reintubation rates, at 2,691 m (8,828 ft.) above sea level, even in patients with single ventricle physiology.We report the case of a 21-year-old woman who was referred with uncontrolled hypertension. Computed tomography angiography revealed aortic arch hypoplasia and severe aortic coarctation. An off-pump ascending-to-descending aortic bypass surgery using synthetic graft was performed via left anterolateral thoracotomy. The patient recovered well and was discharged home uneventfully after five days. TGF-beta inhibitor This procedure was performed without touching the head vessels or any collateral vessels. We consider this a safe and less invasive alternative technique for adult coarctation patients who have aortic hypoplasia or interrupted aorta.Autograft root dilation is common after the unsupported Ross procedure. In the absence of valvar incompetence, and with the perception that dissection is exceedingly rare, expectant management of autograft aneurysm is common practice. Autograft dissection may not be as rare as thought though, as at this point 7 case reports have accrued that describe autograft dissection requiring urgent operative intervention. All had a bicuspid native aortic valve. Bicuspid aortic valve has been shown to be associated with an intrinsic, histologically demonstrated pulmonary arteriopathy, possibly contributing to autograft root dilation and dissection. Autograft root dilation can no longer be regarded as benign, especially in patients with bicuspid aortic valve. Mounting evidence further validates the practice of externally supporting the Ross autograft. For patients who have had an unsupported Ross procedure, mounting evidence may support earlier intervention for autograft root dilation and aneurysm.

Low-dose multidetector computed tomographic angiography (MDCTA) is playing an increasingly larger role in the diagnosis of anomalous pulmonary venous return (APVR). Despite advances in new computed tomographic (CT) techniques with radiation dose reduction, there are limited studies describing radiation dose parameters to allow routine use of cardiac CT in infants and children with APVR. This study compares cardiac CT findings with intraoperative findings and describes comprehensive radiation exposure parameters.

A retrospective analysis of 27 patients compared MDCTA and intraoperative or cardiac catheterization findings of the pulmonary venous anatomy.

A total of 32 MDCTA studies were performed on these 27 patients. Of the 28 studies with subsequent intervention, MDCTA accurately diagnosed the anomalous pulmonary venous anatomy in 27 (96.4%) patients. Narrowing of the pulmonary venous confluence entrance to the coronary sinus was missed on cardiac CT in one patient due to motion artifact, but it was noted intraoperatively. Median estimated effective radiation dose was 0.98 mSv (range 0.39-3.2 mSv), and mean estimated effective radiation dose was 1.1 ± 0.68 mSv. Median total dose length product (DLP) was 25 mGy cm (range 10-83 mGy cm), and mean total DLP was 28 ± 18 mGy cm. Median CTDI volume was 3.8 mGy (range 2.5-14.6 mGy), and mean CTDI volume was 5.0 ± 3.2 mGy.

We conclude that modern cardiac MDCTA is the best imaging modality to guide management in both preintervention and postintervention APVR patients. In this study, we describe comprehensive radiation exposure parameters in infants and children with APVR.