Huffmanwinstead2834
175). Scores for FM and values for pressure pain thresholds of the thumbnail were associated with neck flexor muscle strength (respectively, r = -0.320, P = .013, and r = 0.467, P < .001), endurance (r = -0.242, P < .001, and r = 0.335, P = .009), and plantar flexor muscle strength (r = -0.469, P < .001, and r = 0.500, P < .001).
We found associations between the degree of CS and remote muscle strength and endurance, suggesting that poor remote muscle performance is possibly a clinical sign of CS in people with CLBP.
We found associations between the degree of CS and remote muscle strength and endurance, suggesting that poor remote muscle performance is possibly a clinical sign of CS in people with CLBP.
The purpose of this study was to compare postural control and neurophysiologic components of balance after dry needling of the fibularis longus between individuals with chronic ankle instability (CAI) and a healthy control group.
This quasi-experimental university-laboratory study included 50 adult volunteers-25 with CAI (16 female, 9 male; age 26 ± 9.42 years; height 173.12 ± 9.85 cm; weight 79.27 ± 18 kg) and 25 healthy controls (15 female, 10 male; age 25.8 ± 5.45 years; height 169.47 ± 9.43 cm; weight 68.47 ± 13 kg). Participants completed the Star Excursion Balance Test (SEBT), single-leg balance, and assessment of spinal reflex excitability before and after a single treatment of dry needling to the fibularis longus. The anterior, posterolateral, and posteromedial directions of the SEBT were randomized, and reach distances were normalized to a percentage of leg length. A composite SEBT score was calculated by averaging the normalized scores. Postural control was assessed in single-limb stance on a fo improvement in measures of static and postural control in individuals with CAI as well as healthy controls.
The purpose this study was to investigate the reliability of a handheld myotonometer in measuring the mechanical properties of the neck and orofacial muscles in asymptomatic individuals.
The study included 16 healthy participants. The mechanical properties (frequency, decrement, stiffness, relaxation time, and creep) of the selected muscles were measured with a MyotonPRO myotonometer (Mumeetria Ltd, Tallinn, Estonia). The sternocleidomastoid, upper trapezius, cervical extensor, and masseter muscles were selected to determine the reliability of the device. Measurements were performed by 2 examiners to determine interrater reliability; for intrarater reliability, an examiner repeated the measurements 1 week after the first measurements.
The results revealed moderate to excellent intrarater and interrater reliability (intraclass correlation coefficients 0.50-0.95) in measuring muscle mechanic properties. The standard error of measurement in the tested muscles ranged from 0.3 to 0.8 Hz for frequency, from 7.4 to 20.9 N/m for stiffness, from 0.1 to 0.2 for decrement, and from 0.8 to 1.4 ms for relaxation time. The minimum detectable change ranged from 0.8 to 2.2 Hz for frequency, from 20.5 to 57.9 N/m for stiffness, from 0.2 to 0.6 for decrement, from 2.2 to 3.9 ms for relaxation time, and from 0.2 to 0.3 for creep. selleck kinase inhibitor In addition, the coefficients of variation were below 9.1% for all the assessed parameters.
The obtained results demonstrate that the MyotonPRO device is a reliable and repeatable tool to quantify the frequency, stiffness, decrement, relation time, and creep of the neck and orofacial muscles in asymptomatic individuals.
The obtained results demonstrate that the MyotonPRO device is a reliable and repeatable tool to quantify the frequency, stiffness, decrement, relation time, and creep of the neck and orofacial muscles in asymptomatic individuals.
The purpose of this study was to assess the reliability and construct validity of, and perform confirmatory factor analysis of, the Persian version of the Coping Strategies Questionnaire (CSQ) for Iranian people with nonspecific chronic neck pain.
We performed psychometric testing of the Persian version of the Coping Strategies Questionnaire. Participants were 123 native Persian speakers with chronic neck pain lasting at least 3 months. They were between 18 and 55 years old. The CSQ was administered by self-report. After 5 to 7 days, 94 participants completed the questionnaire in the retest session. Confirmatory factor analysis was done to assess the model fit (χ
test, comparative fit index, and root-mean-square error of approximation) of the 7-factor solution of the Persian version of the CSQ. The Cronbach α was used for internal consistency; intraclass correlation coefficient, standard error of measurement, and minimal detectable change for reliability; and nonparametric tests of group differences andn because of the limitations of the study.
The purpose of this study was to assess whether dry needling (DN) added to photobiomodulation (PBM) has effects on the treatment of active myofascial trigger points in the upper trapezius.
This study was a randomized clinical trial, with 43 participants divided into 3 groups DN and PBM (DNP), DN, and DN outside of the trigger point (DNout). Each group received 1 session of DN followed by PBM therapy with the machine turned on or off. Pain, disability, pain pressure threshold, and muscle activity were assessed before the intervention and afterward at intervals of 10 minutes, 30 minutes, 1 week, and 1 month.
Pain decreased after intervention in the DNP and DNout groups, with mean differences, respectively, of 1.33 cm (95% confidence interval [CI], 0.019-2.647) and 2.78 cm (95% CI, 1.170-2.973). Scores for the disability questionnaire decreased in all groups after intervention (F = 36.53, P < .0001) after the intervention, with mean differences of 3.8 points in the DNP group (95% CI, 1.082-5.518), 3.57 N applied directly on the trigger point.
The aims of this study were to quantify the effects of spinal mobilization on force production, failure point, and muscle activity of the hamstrings during the Nordic hamstring exercise (NHE), and to explore individual differences in responses.
In a replicated randomized crossover trial, 24 asymptomatic, recreationally active men (age [mean ± standard deviation] 27 ± 6 years; body mass 82 ± 17 kg; height 181 ± 8 cm) completed 2 standardized intervention trials (L4/5 zygapophyseal mobilizations) and 2 control trials. The failure point of the NHE was determined with 3D motion capture. Peak force, knee flexor torque, and electromyography (EMG) of the biceps femoris were measured. Data analyses were undertaken to quantify mean intervention response and explore any individual response heterogeneity.
Mean (95% confidence interval) left-limb force was higher in intervention than in control trials by 18.7 (4.6-32) N. Similarly, right-limb force was higher by 22.0 (3.4-40.6) N, left peak torque by 0.14 (0.06-0.22) N • m, and right peak torque by 0.