Chappelldickey1198
The temporal lifting technique can provide lateral facial lifting when administering hyaluronic acid (HA)-based soft tissue fillers into the subdermal plane of the temple. However, the central facial oval is not influenced by this technique.
To identify the safety and esthetic effectiveness of additional midfacial injection points (in addition to the temporal lifting technique) that can volumize the medial midface, lift the lateral face, and increase jawline contouring when included into a full-face injection algorithm.
The patient records of nine consecutive patients (all females) with a mean age of 35.0 (8.4) years and a mean body mass index of 21.7 (2.4)kg/m
were retrospectively analyzed after a full-face injection algorithm was performed using HA-based fillers. The additional injection points target the supraperiosteal plane of the medial zygomatic arch, the lateral infraorbital region, and the pyriform fossa using both needles and cannula.
No adverse events were observed during the 6-month retrospective observational period. The volume of the medial midface increased, the volume of the lateral midface decreased, and the contour of the jawline improved; all effects reached a highly statistically significant level with p<0.001.
Despite each individual injection is currently performed on a daily clinical basis the evaluated injection algorithm following the temporal lifting technique shows some evidence that it is safe and esthetically effective. Future studies will need to confirm the results presented herein in a larger sample and with objective outcome measures to guide safe and effective esthetic outcomes.
Despite each individual injection is currently performed on a daily clinical basis the evaluated injection algorithm following the temporal lifting technique shows some evidence that it is safe and esthetically effective. D4476 Future studies will need to confirm the results presented herein in a larger sample and with objective outcome measures to guide safe and effective esthetic outcomes.Activity-based E2 conjugating enzyme (E2)-ubiquitin (Ub) probes have recently emerged as effective tools for studying the molecular mechanism of E3 ligase (E3)-catalyzed ubiquitination. However, the preparation of existing activity-based E2-Ub probes depends on recombination technology and bioconjugation chemistry, limiting their structural diversity. Herein we describe an expedient total chemical synthesis of an E2 enzyme variant through a hydrazide-based native chemical ligation, which enabled the construction of a structurally new activity-based E2-Ub probe to covalently capture the catalytic site of Cys-dependent E3s. Chemical cross-linking coupled with mass spectrometry (CXMS) demonstrated the utility of this new probe in structural analysis of the intermediates formed during Nedd4 and Parkin-mediated transthiolation. This study exemplifies the utility of chemical protein synthesis for the development of protein probes for biological studies.
There are currently not many publications on the safety of thermomechanical ablation (TMA) devices, and those that are published only have small numbers of subjects. This treatment is gaining popularity in Europe and Asia, and thus there is a need to look at the safety of this treatment.
The purpose of this retrospective study was to evaluate the safety of the clinical use of the novel TMA system (Tixel, Novoxel, Israel) for facial rejuvenation and treatment of acne scars.
We did a retrospective review of our first 150 patients who were treated with the TMA device.
One hundred and fifty consecutive patients aged 20years to 82years with Fitzpatrick skin types I to V treated with the TMA device were included in this study. The total number of treatment sessions was 327 (average 2.18 treatment per patient). The total number of pulses delivered to these patients was 1 48 856 (average 455 pulses per session). The indications for the treatment were photodamaged skin (n=145) and acne scarring (n=5). All patients were able to use makeup immediately after the treatment at lower settings, thus needing no real recovery time. Patients treated at higher settings were able to use makeup after 2days. There were four reported complications post-inflammatory hyperpigmentation (n=2), impetigo (n=1), and dermatitis (n=1).
Using the TMA device in the treatment of photodamage and acne scarring is safe in skin types I to V and has a low incidence of temporary side effects with no permanent side effects.
Using the TMA device in the treatment of photodamage and acne scarring is safe in skin types I to V and has a low incidence of temporary side effects with no permanent side effects.
Non-invasive body contouring devices have fewer side effects and are the new techniques for the treatment of obesity. The present study aimed to evaluate the effects of microwave technology on the abdominal obesity and anthropometric indices of overweight adults.
This clinical trial was conducted on 53 overweight adults aged 18-65years who referred to Behbood Clinic in Tehran, Iran. The participants were exposed to microwave technology (radiofrequency 2.5GHz) based on a standard treatment protocol at three intervals (0, 20, and 40days). Abdominal obesity, body mass index, waist-to-hip ratio, body fat mass, and fat thickness were measured at the beginning and 20, 40, and 60days after the study. In addition, three-day dietary records were collected at intervals.
In total, 77.6% of the subjects were female and 22.4% were male. The mean calorie intake of the participants was 2245.14±1981.16kcal/day. Microwave shock significantly reduced fat thickness in four abdominal areas (p<0.001). Moreover, waist circumference (p<0.001) and total fat thickness of the abdomen decreased (p=0.003 and p=0.002, respectively).
According to the results, microwave technology and radiofrequency could effectively reduce anthropometric indices. In general, the reduction of these indicators and weight may be more significant in men compared to women.
According to the results, microwave technology and radiofrequency could effectively reduce anthropometric indices. In general, the reduction of these indicators and weight may be more significant in men compared to women.