Borregaardkearns9769

Z Iurium Wiki

In this study, superhydrophobic titania nanoflower surfaces were successfully fabricated on a titanium alloy Ti-6Al-4V substrate with hydrothermal synthesis and vapor-phase silanization. The surface topography, surface wettability, surface chemistry, and surface crystallography of the surfaces was subsequently characterized. Surface hemocompatibility was investigated through lactate dehydrogenase (LDH) cytotoxicity analysis, blood-plasma protein adsorption, platelet and leukocyte adhesion and activation, and whole blood clotting analysis. Surface bacterial infection was characterized through Gram-positive and Gram-negative bacterial adhesion and biofilm morphology. The results indicated a reduction of protein adsorption, platelet and leukocyte adhesion and activation, bacterial adhesion, and biofilm formation as well as improved contact angle stability compared to control surfaces.Current outbreaks associated with drug-resistant clinical strains are demanding for the development of broad-spectrum antibacterial agents. selleck compound The bactericidal materials should be eco-friendly, economical and effective to suppress bacterial growth. Thus, in this work, diameter controlled spherical Cucore-Agshell nanoparticles (Ag@CuNPs) with diameter ranging from 70 to 100 nm by one-step co-reduction approach were designed and synthesized. The Ag@CuNPs were homogenous, stable, and positively charged. The 70 nm Ag@CuNPs showed a consistent and regular Ag shielding. We observed the 100 nm Ag@CuNPs achieved symmetrical doped Ag clusters on the Cu core surface. We used Gram-positive and Gram-negative models strains to test the wide-spectrum antibacterial activity. The Ag@CuNPs showed detrimental microbial viability in a dose-dependent manner; however, 70 nm Ag@CuNPs were superior to those of 100 nm Ag@CuNPs. Initially, Ag@CuNPs attached and translocated the membrane surface resulting in bacterial eradication. Our analyses exhibited that antibacterial mechanism was not governed by the bacterial genre, nonetheless, by cell type, morphology, growing ability and the NPs uptake capability. The Ag@CuNPs were highly tolerated by human fibroblasts, mainly by the use of starch as glucosidic capper and stabilizer, suggesting optimal biocompatibility and activity. The Ag@CuNPs open up a novel platform to study the potential action of bimetallic nanoparticles and their molecular role for biomedical, clinical, hospital and industrial-chemical applications.Many features that are appropriate for an ideal tissue engineered biomaterial are found in plant tissues. Hierarchically organized Bambusa vulgaris exhibits structural similarities to native bone, but the degradation of cellulose that is the main component of the plant cell wall is a challenge. In this study, Bamboo stem was subjected to decellularization followed by a chemical oxidation process (treated with sodium periodate) to enhance biocompatibility and biodegradation. The crystallinity of oxidised plant scaffolds was reduced, resulting in lower mechanical strength. In contrast, hydrophilicity was enhanced in those scaffolds. In vitro studies demonstrated better mesenchymal stem cell adhesion, viability, and osteogenic differentiation on oxidized scaffolds. Those scaffolds also induced angiogenesis, biocompatibility, and biodegradation when implanted subcutaneously in vivo. Hence, the present study demonstrated the usefulness of "oxidized decellularized plant" as bone scaffold for non-load-bearing applications.Understanding a complex interaction between therapeutic nanoparticles and biological entities is crucially important for the development of effective disease treatments in the modern nanopharmaceuticals and nanomedicines. Herein, we present a strategy to thoroughly assess geometrical impacts of silver nanoparticles (AgNPs, one of the most promising nanotherapeutic agents) on their biological activities toward treatment of Staphylococcus aureus (S. aureus)-induced keratitis. Specifically, three types of differently shaped AgNPs including silver nanorods (R-Ag), silver nanotriangles (T-Ag), and silver nanospheres (SAg) are employed and interferences of particle surface area and functionality are eliminated to reflect purely geometric effects. Ocular biocompatibility studies on rabbit corneal keratocytes reveal that SAg is the least cytotoxic agent while R-Ag, because of its strongest cellular uptake, induces highest cytotoxic levels. Moreover, SAg is demonstrated to outperform R-Ag and T-Ag in killing S. aureuse-related microbial infections.Antibacterial coating is an important strategy preventing bacterial colonization and biofilm formation. One-step synthesis of nanocapsule-containing antibacterial coatings with controlled release of Ag+ ions was achieved in the current work by aerosol-assisted atmospheric pressure plasma deposition. The experimental parameters of deposition including the discharge power, silver nitrate concentration, aerosol flow rate, continuous and pulsed mode of operation were studied in order to analyze their effects on surface morphology and chemical composition of the coating. Formation of nanocapsules embedded in the polymeric coating was observed. A core-shell structure was found for nanocapsule with silver in the core and polymer in the shell. Antibacterial coatings on polyethylene terephthalate film were studied in terms of Ag+ ion release, antibacterial properties against Escherichia coli and Staphylococcus aureus, and cytotoxicity with murine fibroblasts. Two-phase release kinetics of Ag+ ions was observed as initially a short-term burst release followed by a long-term slow release. It was revealed that high antibacterial efficiency of the coatings deposited on polyethylene terephthalate films can be coupled with low cytotoxicity. These biocompatible antibacterial coatings are very promising in different fields including biological applications.The friction and wear properties of silica/poly(tetrahydrofuran)/poly(ε-caprolactone) (SiO2/PTHF/PCL-diCOOH) hybrid materials that are proposed as cartilage tissue engineering materials were investigated against living articular cartilage. A testing rig was designed to allow testing against fresh bovine cartilage. The friction force and wear were compared for five compositions of the hybrid biomaterial articulating against freshly harvested bovine cartilage in diluted bovine calf serum. Under a non-migrating contact, the friction force increased and hence shear force applied to the opposing articular cartilage also increased, resulting in minor damage to the cartilage surface. This worse case testing scenario was used to discriminate between material formulations and revealed the increase in friction and damaged area was lowest for the hybrid containing the most silica. Further friction and wear tests on one hybrid formulation with an elastic modulus closest to that of cartilage were then conducted in a customonstrates how tribological testing can be integrated into the design process to produce materials with a higher chance of clinical success.Many tubular tissues such as blood vessels and trachea can suffer long-segmental defects through trauma and disease. With current limitations in the use of autologous grafts, the need for a synthetic substitute is of continuous interest as possible alternatives. Fabrication of these tubular organs is commonly done with techniques such as electrospinning and melt electrowriting using a rotational collector. Current additive manufacturing (AM) systems do not commonly implement the use of a rotational axis, which limits their application for the fabrication of tubular scaffolds. In this study, a four axis extrusion-based AM system similar to fused deposition modeling (FDM) has been developed to create tubular hollow scaffolds. A rectangular and a diamond pore design were further investigated for mechanical characterization, as a standard and a biomimicry pore geometry respectively. We demonstrated that in the radial compression mode the diamond pore design had a higher Young's modulus (19,8 ± 0,7 MPa compared to 2,8 ± 0,5 MPa), while in the longitudinal tensile mode the rectangular pore design had a higher Young's modulus (5,8 ± 0,2 MPa compared to 0,1 ± 0,01 MPa). Three-point bending analyses revealed that the diamond pore design is more resistant to luminal collapse compared to the rectangular design. This data showed that by changing the scaffold pore design, a wide range of mechanical properties could be obtained. Furthermore, a full control over scaffold design and geometry can be achieved with the developed 4-axis extrusion-based system, which has not been reported with other techniques. This flexibility allow the manufacturing of scaffolds for diverse tubular tissue regeneration applications by designing suitable deposition patterns to match their mechanical pre-requisites.Fibers produced from electrospinning are well-known to be extremely fine with diameters ranging from tens of nanometers to a few microns. Such ultrafine fibers not only allow for engineering scaffolds resembling the ultrastructure of the native extracellular matrix, but also offer possibility to explore the remodeling behavior of cells in vitro, due to their mechanically 'adequate' softness endowed by their ultrafine fineness. However, the remodeling effect of cells on the biomimicking fibrous substrates remains to be understood, because the crisscrossing and entangling among nanofibers in those tightly packed fibrous mats ultimately lead to merely a topological phenomenon, similar to that of the nanofiber-like topography embossed on the surface of a solid matter. In this study, the effect of nanofiber density on cellular response behavior was investigated by reducing the density of electrospun fiber networks. Using polycaprolactone (PCL) as a model polymer, randomly oriented fiber networks with various densiclose the dependence of cellular responses on fiber density. This study paves the way to precisely design biomimetic fibrous scaffolds for achieving enhanced cell-scaffold interactions and tissue regeneration.The preparation of long-wavelength emitting carbon dots (CDs) with good antibacterial function and biosensing ability through element doping method is the hotspot of present researches. This paper reports the rapid synthesis of nitrogen and phosphorus co-doped long wavelength-emitting CDs (N, P-CDs, λem = 530 nm) under low reaction temperature (30 min, 60 °C). This method used glucose, polyethyleneimine and phosphoric acid as raw materials, and each raw material worked multi-functionally during the synthesis process. The impacts of raw materials and reaction parameters upon optical properties of prepared N, P-CDs have been studied, and the synthesis mechanism has been discussed. Meanwhile, N, P-CDs were used as antibacterial material with minimum inhibitory concentrations against Staphylococcus aureus and Escherichia coli at 7.5 μg·mL-1 and 0.5 mg·mL-1 respectively. The prepared CDs were also used to realize fluorescence imaging of S. aureus, and work as fluorescence probe to detect Sudan Red I with limit of detection at 43 nM.Nanostructured materials such as nanoparticles and nanoporous materials strongly affect cell behaviors such as cell viability. Because cellular uptake of nanoporous materials does not occur, mechanisms for the effects of nanoporous materials on cells are different from those of nanoparticles. The effects of nanoporous materials on cells are thought to result from large conformational changes in the extracellular matrix (ECM) induced by the nanoporous materials, although the mechanotransduction and the critical focal adhesion cluster size also have an effect on the cell response. However, we show that the adhesion of mesenchymal stem cells to a gold surface is reduced for nanoporous gold (NPG), despite the conformational changes in collagen induced by NPG being below the detection limits of the experimental analyses. The adsorption dynamics of collagen on NPG are investigated by molecular dynamics simulations to determine the origin of the reduced cell adhesion to NPG. The adsorption energy of collagen on NPG is lower than that on flat gold (FG) despite there being little difference between the global conformation of collagen segments adsorbed on NPG compared with FG.

Autoři článku: Borregaardkearns9769 (Noble Melendez)