Aagesencovington0783

Z Iurium Wiki

Notably, infiltration efficiency ranged from 0.22 to 0.76 across the four facilities. We propose that this variability is evidence that PM2.5 infiltration may be impacted by modifiable building characteristics and human behavioral factors, and this should be addressed in future studies.Accurate prediction of the non-uniform contaminant distribution under stratum ventilation (SV) is crucial for optimal design for reducing contaminant exposure risks. Compared with experiments and computational fluid dynamics, zonal models are convenient to implement. This study proposes a zonal model for predicting dynamic non-uniform contaminant distribution in the stratum ventilated room. The zoning method is based on the unique airflow pattern under SV, and the room is divided into the jet zone, entrainment zone, and the mixing zone. The interzonal airflow rate is derived from the profile of the supply air jet. The results show that the proposed zonal model can predict the dynamic contaminant distribution in the stratum ventilated room. Compared with the experimental measurement, the predictions show good accuracy with the mean absolute error (MAE) at 0.51-2.36 ppm and root mean squared error (RMSE) at 0.64-2.53 ppm. The error of the proposed zonal model is influenced by the degree of mixing in each subzone. The proposed zonal model shows better accuracy for non-uniform air distribution under stratum ventilation compared with the existing zonal model.The exhalation of aerosols during musical performances or rehearsals posed a risk of airborne virus transmission in the COVID-19 pandemic. Previous research studied aerosol plumes by only focusing on one risk factor, either the source strength or convective transport capability. Furthermore, the source strength was characterized by the aerosol concentration and ignored the airflow rate needed for risk analysis in actual musical performances. This study characterizes aerosol plumes that account for both the source strength and convective transport capability by conducting experiments with 18 human subjects. The source strength was characterized by the source aerosol emission rate, defined as the source aerosol concentration multiplied by the source airflow rate (brass 383 particle/s, singing 408 particle/s, and woodwind 480 particle/s). The convective transport capability was characterized by the plume influence distance, defined as the sum of the horizontal jet length and horizontal instrument length (brass 0imately five times more source aerosol concentrations than those of the other musicians who played the same instrument. Despite voice and brass instruments producing measurably lower average risk, it is possible to have an individual musician produce aerosol plumes with high source strength, resulting in enhanced transmission risk; however, our sample size was too small to make generalizable conclusions regarding the broad musician population.Heating and cooling requirement differences across climates not only have carbon emissions and energy efficiency implications but also impact indoor air quality (IAQ) and health. Energy and IAQ building simulation models help understand tradeoffs or co-benefits, but these have not been applied to evaluate climate zone or multi-family home differences. We modeled a four-story multi-family home in six U.S. climate zones and quantified energy, IAQ, and health outcomes with EnergyPlus, CONTAM, and a pediatric asthma systems science model. U0126 solubility dmso Pollutant sources included cooking and ambient. Outputs were daily PM2.5 and NO2 indoor concentrations, infiltration, energy for heating and cooling, and asthma exacerbations, which were compared across climate zones, apartment units, and resident behaviors. Daily ambient-sourced PM2.5 decreased and cooking-sourced PM2.5 increased with higher ambient temperatures. Infiltration air changes per hour were higher on the first versus the fourth floor and in colder climates. Window opening during cooking led to decreases in total pollutant concentrations (11%-18% for PM2.5 and 9%-15% for NO2 ), 3%-4% decreases in asthma exacerbations within climate zones, and minimal impacts on cooling, but led to increased heating demand (4%-8%). Our results demonstrate the influence of meteorology, multi-family building characteristics, and resident behavior on IAQ, energy, and health, focused on multi-zone methodology.The importance of photolysis as an initiator of air chemistry outdoors is widely recognized, but its role in chemical processing indoors is often ignored. This paper uses recent experimental data to modify a detailed chemical model, using it to investigate the impacts of glass type, artificial indoor lighting, cloudiness, time of year and latitude on indoor photolysis rates and hence indoor air chemistry. Switching from an LED to an uncovered fluorescent tube light increased predicted indoor hydroxyl radical concentrations by ~13%. However, moving from glass that transmitted outdoor light at wavelengths above 380 nm to one that transmitted sunlight above 315 nm led to an increase in predicted hydroxyl radicals of more than 400%. For our studied species, including ozone, nitrogen oxides, nitrous acid, formaldehyde, and hydroxyl radicals, the latter were most sensitive to changes in indoor photolysis rates. Concentrations of nitrogen dioxide and formaldehyde were largely invariant, with exchange with outdoors and internal deposition controlling their indoor concentrations. Modern lights such as LEDs, together with low transmission glasses, will likely reduce the effects of photolysis indoors and the production of potentially harmful species. Research is needed on the health effects of different indoor air mixtures to confirm this conclusion.Common cold is usually considered to be associated with outdoor climate, but the evidence linking with indoor environmental factors is lacking. The role of indoor renovations during which critical timing window on childhood common cold remains unclear. Therefore, we investigated the effect of exposure to new furniture and/or redecoration during prenatal and postnatal periods on the occurrence and duration of common cold in preschool children. We conducted a retrospective cohort study of 39 782 children aged 3-6 years in seven cities of China. The occurrence and duration of common cold in children, and their lifetime exposures to indoor new furniture and redecoration (including pregnancy, the first year of life, and after one year old) were assessed using a questionnaire administered by the parents. Associations between high frequency (>5 colds) and long duration (≥2 weeks per cold) of common cold during past 12 months and exposure to indoor new furniture/redecoration were examined by logistic regression modelied by some personal and indoor environmental factors. Our findings indicated that prenatal and postnatal exposure to home renovation played an important role in the risk of childhood common cold, supporting the hypothesis of "fetal origin of childhood infection."A building's indoor climate is an essential input variable for a variety of building physics computational models, simulations, and analyses. Precise knowledge of the indoor climate is necessary to minimize the risk of mold or moisture damage and is required to ensure minimum heat insulation standards in buildings. Detailed data are especially necessary for the progressive application of transient calculations, for example, concerning thermal comfort or energy consumption. While the properties of building materials and the (local) outdoor climate are known, only rudimentary information about the dynamic indoor climate is available. Most existing information in the literature about indoor climate is fairly general and forgoes a differentiation between climatic region, occupancy profile, and the utilization of rooms. In this paper, we report on indoor climate measurements in naturally ventilated apartments over a period of 1 year. The measurement results complement the existing data to provide accurate indoor crding condensation risk and mold damage in naturally ventilated rooms.Secondhand smoke (SHS) remains a common health threat in densely populated, urban settings. We estimated the prevalence of exposure and associated respiratory symptoms, knowledge, attitudes, and behaviors in a multi-ethnic, weighted sample of Singapore residents using a cross-sectional survey of 1806 adults. We weighted data to match the national population in terms of gender, ethnicity, and education level and analyzed data using descriptive statistics, bivariate analyses, multiple linear and logistic regressions, and a multinomial logistic regression model. About 88% of respondents reported regular SHS exposure. Nearly 57% reported exposure to neighbors' SHS at home. Respiratory symptoms were reported by 32.5% and significantly associated with exposure to daily (AOR = 2.63, 95% CI = 1.62-4.36), non-daily (AOR = 1.75, 95% CI = 1.14-2.77), and neighbors' (AOR = 1.37, 95% CI = 1.07-1.76) SHS. More knowledge of SHS was associated with male gender (β = 0.28, p = 0.0009) and higher household income (linear trend; p = 0.0400). More negative attitudes to SHS were associated with older age (linear trend; p  less then  0.0001). Engaging in behaviors to avoid SHS was associated with a more negative attitude to SHS (AOR = 1.09-1.23). SHS exposure is common in Singapore's densely populated setting and associated with respiratory symptoms, even if exposure is non-daily or from neighboring homes.Environmental carbon dioxide (CO2 ) could affect various mental and physiological activities in humans, but its effect on daytime sleepiness is still controversial. In a randomized and counterbalanced crossover study with twelve healthy volunteers, we applied a combinational approach using classical frequentist and Bayesian statistics to analyze the CO2 exposure effect on daytime sleepiness and electroencephalogram (EEG) signals. Subjective sleepiness was measured by the Japanese Karolinska Sleepiness Scale (KSS-J) by recording EEG during CO2 exposure at different concentrations Normal (C), 4000 ppm (Moderately High MH), and 40 000 ppm (high H). The daytime sleepiness was significantly affected by the exposure time but not the CO2 condition in the classical statistics. On the other hand, the Bayesian paired t-test revealed that the CO2 exposure at the MH condition might induce daytime sleepiness at the 40-min point compared with the C condition. By contrast, EEG was significantly affected by a short exposure to the H condition but not exposure time. The Bayesian analysis of EEG was primarily consistent with results by the classical statistics but showed different credible levels in the Bayes' factor. Our result suggested that the EEG may not be suitable to detect objective sleepiness induced by CO2 exposure because the EEG signal was highly sensitive to environmental CO2 concentration. Our study would be helpful for researchers to revisit whether EEG is applicable as a judgment indicator of objective sleepiness.Understanding airborne infectious disease transmission on public transport is essential to reducing the risk of infection of passengers and crew members. We propose a new one-dimensional (1D) model that predicts the longitudinal dispersion of airborne contaminants and the risk of disease transmission inside a railway carriage. We compare the results of this 1D-model to the predictions of a model that assumes the carriage is fully mixed. The 1D-model is validated using measurements of controlled carbon-dioxide experiments conducted in a full-scale railway carriage. We use our results to provide novel insights into the impact of various strategies to reduce the risk of airborne transmission on public transport.

Autoři článku: Aagesencovington0783 (Cooke Bolton)