Berrybradford3732

Z Iurium Wiki

Verze z 30. 12. 2024, 23:26, kterou vytvořil Berrybradford3732 (diskuse | příspěvky) (Založena nová stránka s textem „The aims of the study were to determine whether a volar lunate facet fragment is present in 67 displaced intra-articular distal radius fractures and to inv…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

The aims of the study were to determine whether a volar lunate facet fragment is present in 67 displaced intra-articular distal radius fractures and to investigate which factors are associated with reduction loss after treatment with a volar plate and locking screws. The fractures were analyzed preoperatively with three-dimensional computed tomography. The volar lunate facet fragment was present in 42 fractures. Reduction loss occurred in five wrists and in two of those, the carpus was subluxated. Loss of reduction was associated with a short palmar cortex (9mm or less) of the volar lunate facet fragment. This study has shown that measuring the length of the palmar cortex of a volar lunate facet fracture fragment may be useful for identifying distal radius fractures that have a higher risk of displacement after treatment with a standard volar plate and locking screws. The aim of this prospective study was to describe the surgical procedure and to report outcomes of computer-assisted 3D preoperative planning of corrective osteotomy for extra-articular distal radius malunions. Sixteen consecutive patients were enrolled. CT scans of both wrists were performed, and 3D bone surface models of the radii were created. Software was used to simulate the osteotomy and the reorientation of the distal radial articular surface. Patient-specific cutting and drilling guides for intraoperative guidance of the osteotomy as well as bone graft templates were also simulated. At a mean follow-up of 12 months (range 6-27) after surgery, pain was reduced from 3 to 0.3 at rest and 6.8 to 1.5 during effort according to a visual analog scale. The average wrist flexion-extension was 145° and pronation-supination was 155°. Grip strength was 91% of the contralateral side. All patients achieved primary bone union in a mean of 10 weeks (range, 7-18). Using our 3D analysis method, preoperative 3D values showed no significant difference with radiographic measurement. Moreover, there was no significant difference between the postoperative radiographic values in term of correction. This procedure provides satisfactory clinical and radiological results with minimal residual malalignment. LEVEL OF EVIDENCE III. NLRP3 (NOD-, LRR- and pyrin domain- containing protein 3) inflammasome is involved in diverse inflammatory diseases, so the activation of NLRP3 inflammasome needs to be tightly regulated to prevent excessive inflammation. However, the endogenous regulatory mechanisms of NLRP3 inflammasome are still less defined. Here, we report that β-catenin, which is the central mediator of the canonical Wnt/β-catenin signaling, promotes NLRP3 inflammasome activation. When we suppressed the expression of β-catenin by siRNA or pharmacological inhibitor, the NLRP3 inflammasome activation was impaired. Accordingly, β-catenin inhibitor attenuated LPS-induced systemic inflammation in vivo. Mechanistically, we found β-catenin interacted with NLRP3 and promoted the association between NLRP3 and ASC. Thus, our study revealed a novel role of β-catenin in NLRP3 inflammasome activation and suggest an endogenous crosstalk between Wnt/β-catenin signal and NLRP3 inflammasome. PURPOSE To evaluate the clinical benefits and complications of vesselplasty using the Mesh-Hold™ bone-filling container in the treatment of vertebral osteolytic fractures. METHODS This was a retrospective study of patients with vertebral osteolytic pathological fractures treated by vesselplasty at Sichuan Cancer Hospital between 09/2014 and 01/2018. VAS1 (Visual analog scale) scores and ODI2 (Oswestry disability index) were recorded routinely 1 day preoperative, at 1 day, 1 month, 3 months, 6 months, and 1 year postoperation, and at the last follow-up. V13 (The of bone cement injection volume) and V24 (vertebral body osteolytic volume) were evaluated, and the R5 (ratio) of bone cement filling was obtained according to the V1/V2. RESULTS Sixty-three patients were included (105 segments with osteolytic fractures). The amount of bone cement for each vertebra was 2.4-5.2 ml (3.1 ± 0.7 ml). The ratio (R) of bone cement filling was not related to pain relief or functional recovery (all P > 0.05).The VAS scores and ODI at different time points after surgery were decreased compared with before surgery (all P  less then  0.05). The bone cement leakage rate was 16.2 % (17/105). The follow-up was 4-30 months (mean of 13 ± 6 months). Thirty patients had died by the last follow-up, all from their cancer. CONCLUSIONS The Mesh-Hold™ bone-filling container in the treatment of vertebral fractures induced by osteolytic metastases could reduce pain, improve function, and reduce the bone cement leakage rate in the process of vesselplasty. PURPOSE To evaluate the in vivo feasibility of a multibolus contrast agent (CA) injection protocol with a reduced CA volume for thoraco-abdominal CT angiography (CTA) and to compare it to a single-bolus CA injection protocol. METHOD 63 patients who underwent CTA with the multibolus protocol (60 ml CA) were divided in two groups either without (group 1, n = 48) or with (group 2, n = 15) aortic dissection. The aortic contrast enhancement was measured in group 1 using manual ROI analysis (10 segments), as well as semi-automated linear attenuation profiles. A subgroup (n = 18) of group 1, who also underwent imaging with the single-bolus protocol (94 ml CA), was used to compare both protocols. In group 2, differences in attenuation of the true and the false lumen for both the single- and the multibolus protocol were assessed with ROI attenuation measurements in both lumina. Comparisons were made using Wilcoxon test. RESULTS Average attenuation was above 200 HU for 98 % of cases using the multibolus protocol. There was superior contrast homogeneity for the multibolus protocol with a lower standard deviation of attenuation values along the length of the scan (p = 0.003), while average attenuation was higher for the single-bolus protocol (p = 0.002). Prolonged enhancement plateau lead to a more uniform opacification of the true and the false lumen in patients with aortic dissection using the multibolus protocol (p = 0.012). CONCLUSIONS The multibolus protocol in thoraco-abdominal CTA is feasible in patients. ABC294640 chemical structure It shows consistently high arterial enhancement with superior contrast homogeneity compared to a single-bolus protocol in patients with and without aortic dissection.

Autoři článku: Berrybradford3732 (Howard Jochumsen)