Verze z 25. 12. 2024, 15:01, kterou vytvořil Vintherbest7149 (diskuse | příspěvky) (Založena nová stránka s textem „Destructive aortic root endocarditis is associated with high mortality rates. The objective of this article was to characterize the clinical and microbiolo…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

Destructive aortic root endocarditis is associated with high mortality rates. The objective of this article was to characterize the clinical and microbiological profiles of these patients, especially concerning an already implanted aortic valve prosthesis. We also focused on prognostic factors.

Eighty patients underwent aortic root replacement due to destructive endocarditis from 1999 to 2018 in our institution. We analyzed their pre, intra, and postoperative data, outcomes, and predictors of mortality.

Thirty-one patients had native valve endocarditis (NVE), eight patients had early-onset prosthetic valve endocarditis (PVE), and 41 patients had late-onset PVE. Streptococcus was found in 19.4% of NVE cases and no PVE case. Coagulase-negative Staphylococcus was responsible for 62.5% of the cases of earlyonset PVE. Thirty-four (42.5%) patients had received inappropriate antibiotics before admission. read more No microorganism was associated with higher risk of mortality. Aortoventricular dehiscence was identified as an independent risk factor of mortality along with PVE, concomitant bypass surgery, and delayed diagnosis. The incidence of postoperative complications was similar in all three groups. Rates of long-term survival (P=0.044) and freedom from the composite endpoint (P=0.024) defined as death, stroke, aortic valve reinfection, and aortic valve reoperation were the lowest within the NVE group and the highest among the PVE patients.

In endocarditis, prolonged diagnostics, inadequate antimicrobial treatment, and late surgery led to destructive local complications and worsened the prognosis. PVE is associated with higher mortality than NVE.

In endocarditis, prolonged diagnostics, inadequate antimicrobial treatment, and late surgery led to destructive local complications and worsened the prognosis. PVE is associated with higher mortality than NVE.

Elevated neutrophil-lymphocyte ratio (NLR) has been associated with poorer outcomes in cyanotic patients undergoing single ventricle palliation. Little is known about this biomarker on patients with tetralogy of Fallot (TOF), the most common cyanotic congenital heart disease. Our objective is to study the impact of preoperative NLR on outcomes of TOF patients undergoing total repair.

This retrospective study included 116 consecutive patients between January 2014 and December 2018. Preoperative NLR was measured from the last complete blood count test before the surgery. Using the cutoff value of 0.80, according to the receiveroperating characteristic (ROC) curve, the sample was divided into two groups (NLR < 0.80 and ≥ 0.80). The primary endpoint was hospital length of stay (LOS).

ROC curves showed that higher preoperative NLR was associated with longer hospital LOS, with an area under the curve of 0.801±0.040 (95% confidence interval 0.722 - 0.879; P<0.001). High preoperative NLR was also associated with long intensive care unit (ICU) LOS (P=0.035). Preoperative NLR predicted longer hospital LOS with a sensitivity of 63% and a specificity of 81.4%.

Higher preoperative NLR was associated with long ICU and hospital LOS in patients undergoing TOF repair.

Higher preoperative NLR was associated with long ICU and hospital LOS in patients undergoing TOF repair.

Sutureless aortic valve replacement (Su-AVR) offers an alternative to supra-annular stented biological aortic prostheses. This single-center study aimed to compare early outcomes after aortic valve replacement with sutureless and conventional stented bioprostheses.

In this retrospective study, we analyzed 52 patients who underwent aortic valve replacement with sutureless and stented bioprostheses between January 2013 and October 2017. Sorin Perceval S sutureless valves were implanted in group 1 and Sorin Mitroflow stented bioprosthetic valves were used in group 2. Postoperative outcomes, including demographics, cardiopulmonary bypass (CPB) times, cross-clamp times, morbidity and mortality, as well as echocardiography in the first month, were compared.

Mortality occurred in 1 (3.6%) patient in group 1, and in 2 (8.3%) patients in group 2 (P=0.186). Group 1 had significantly shorter CPB (61.6±26.1 min vs. 106.3±32.7 min, P=0.001) and crossclamp (30.9±13.6 min vs. 73.3±17.3 min, P=0.001) times. The length of stay in the intensive care unit (1.9±1.3 days vs. 2.4±4.9 days, P=0.598) and hospital stay (7.6±2.7 days vs. 7.3±2.6 days, P=0.66) were similar. Postoperatively, there was no statistically significant difference between the two groups in echocardiography results, and morbidities. The mean aortic valve gradient was 13.5±5.8 mmHg in group 1 and 14.5±8.0 mmHg in group 2 (P=0.634). Paravalvular regurgitation was diagnosed in 3 (10.7%) patients in group 1 and in 1 (4.2%) patient in group 2 (P=0.220).

Su-AVR resulted in shorter cross-clamp and CPB times. However, early mortality, postoperative morbidity, and echocardiography results were similar between groups.

Su-AVR resulted in shorter cross-clamp and CPB times. However, early mortality, postoperative morbidity, and echocardiography results were similar between groups.

Heart transplantation is the treatment indicated for patients with advanced and refractory heart failure (HF). The transplant is expected to increase survival and improve the level of health-related quality of life (HRQoL). The aim of this study was to compare the level of HRQoL, as well as social and clinical variables, between patients with advanced HF and heart transplant (HT) recipients.

This is a cross-sectional study, conducted at a Brazilian university hospital, during outpatient consultations. The level of HRQoL was assessed using the World Health Organization Quality of Life-Bref questionnaire. Descriptive statistics were used to analyze the data, and the comparison of the level of HRQoL was performed using the Mann-Whitney U test.

Two hundred sixty-two patients participated in the study. Seventy-nine of them had advanced-stage HF and 183 were HT recipients. Compared to patients with advanced HF, HT recipients had a better level of HRQoL, were less frequently absent from work due to health problems, had higher income, used a higher number of medications, and there was a higher percentage of retirees among them (P-value < 0.