Advanced microanalytical techniques such as high-resolution transmission electron microscopy (HRTEM), atom probe tomography (APT), and synchrotron-based scanning transmission X-ray microscopy (STXM) enable one to characterize the structure and chemical and isotopic compositions of natural materials down towards the atomic scale. Dual focused ion beam-scanning electron microscopy (FIB-SEM) is a powerful tool for site-specific sample preparation and subsequent analysis by TEM, APT, and STXM to the highest energy and spatial resolutions. FIB-SEM also works as a stand-alone technique for three-dimensional (3D) tomography. In this review, we will outline the principles and challenges when using FIB-SEM for the advanced characterization of natural materials in the Earth and Planetary Sciences. More specifically, we aim to highlight the state-of-the-art applications of FIB-SEM using examples including (a) traditional FIB ultrathin sample preparation of small particles in the study of space weathering of lunar soil grains, (b) migration of Pb isotopes in zircons by FIB-based APT, (c) coordinated synchrotron-based STXM characterization of extraterrestrial organic material in carbonaceous chondrite, and finally (d) FIB-based 3D tomography of oil shale pores by slice and view methods. Dual beam FIB-SEM is a powerful analytical platform, the scope of which, for technological development and adaptation, is vast and exciting in the field of Earth and Planetary Sciences. For example, dual beam FIB-SEM will be a vital technique for the characterization of fine-grained asteroid and lunar samples returned to the Earth in the near future.In this paper, AISI 316L stainless steel part is obtained by laser metal deposition additive manufacturing method. The microstructure of the part was observed and analyzed by an optical microscope. The tensile mechanical properties and residual stress distribution of the part were tested by tensile test and the contour method. The results show that the bulk structure is mainly columnar crystal and equiaxed crystal, and the latter layer of laser metal deposition will form a remelted zone and heat-affected zone in the former deposition zone. Tensile test results show that the tensile strength of tensile specimens parallel to laser scanning direction and perpendicular to laser scanning direction is basically the same, but the elongation of the specimens perpendicular to the laser scanning direction is relatively better. The main reason is the different distribution characteristics of columnar crystals and equiaxed crystals in the two directions. Relatively large deformation occurs on the cut surface of the specimen after low-speed wire cut. The residual stress test results indicate that tensile stress is formed in the upper part and it reaches 315 MPa at the top surface. And compressive stress is formed at the part/substrate interface and the substrate.The use of microfluidics in artificial reproductive technologies for manipulation or assessment of spermatozoa is unique in the sense that it is not always an end point measurement and the sample may be used afterward. During microfluidic processing, spermatozoa are exposed to shear stress, which may harm viability and functioning of spermatozoa. The shear stresses during general microfluidic processing steps were calculated and compared to estimated shear stresses during ejaculation. The viability of boar and bull spermatozoa after microfluidic processing was studied and compared to the typical handling method (centrifugation) and to a control (the sample in a tube at the same temperature). The boar spermatozoa showed a small but significant decrease in viability of 6% after microfluidic handling. Bull spermatozoa proved to be less susceptible to shear stress and were not significantly affected by microfluidic processing. These data indicate that the impact of microfluidic processing on the viability of boar and bull spermatozoa is less than the literature values reported for flow cytometry and comparable to the impact of centrifugation.Label-free microfluidic-based cell sorters leverage innate differences among cells (e.g., size and stiffness), to separate one cell type from another. This sorting step is crucial for many cell-based applications. Polystyrene-based microparticles (MPs) are the current gold standard for calibrating flow-based cell sorters and analyzers; however, the deformation behavior of these rigid materials is drastically different from that of living cells. Given this discrepancy in stiffness, an alternative calibration particle that better reflects cell elasticity is needed for the optimization of new and existing microfluidic devices. Here, we describe the fabrication of cell-like, mechanically tunable MPs and demonstrate their utility in quantifying differences in inertial displacement within a microfluidic constriction device as a function of particle elastic modulus, for the first time. Monodisperse, fluorescent, cell-like microparticles that replicate the size and modulus of living cells were fabricated from polyacrylamide within a microfluidic droplet generator and characterized via optical and atomic force microscopy. Trajectories of our cell-like MPs were mapped within the constriction device to predict where living cells of similar size/modulus would move. Calibration of the device with our MPs showed that inertial displacement depends on both particle size and modulus, with large/soft MPs migrating further toward the channel centerline than small/stiff MPs. Ruboxistaurin order The mapped trajectories also indicated that MP modulus contributed proportionally more to particle displacement than size, for the physiologically relevant ranges tested. The large shift in focusing position quantified here emphasizes the need for physiologically relevant, deformable MPs for calibrating and optimizing microfluidic separation platforms.[This corrects the article DOI 10.1016/j.radcr.2020.01.036.].[This corrects the article DOI 10.1016/j.radcr.2020.04.026.].[This corrects the article DOI 10.1016/j.radcr.2020.05.026.].[This corrects the article DOI 10.1016/j.radcr.2020.05.017.].

Autoři článku: Abildtrupkelleher9127 (Cheek Quinlan)