Kentoakley0367

Z Iurium Wiki

Verze z 16. 11. 2024, 16:15, kterou vytvořil Kentoakley0367 (diskuse | příspěvky) (Založena nová stránka s textem „The reaction of aroyl-substituted donor-acceptor (D-A) cyclopropanes with two equivalents of 1-naphthylamines in the presence of a catalytic amount of scan…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

The reaction of aroyl-substituted donor-acceptor (D-A) cyclopropanes with two equivalents of 1-naphthylamines in the presence of a catalytic amount of scandium(III) triflate provides access to dibenzo[c,h]acridines. The key steps of the transformation are the formation of nucleophilic ring-opening products from the D-A cyclopropanes and 1-naphthylamines and their subsequent fragmentation and cyclization. The method has a reasonable substrate scope, and the products are formed in 50-70% yields.Metabolic phenotyping of tissues uses metabolomics and lipidomics to measure the relative polar and nonpolar (lipid) metabolite levels in biological samples. This approach aims to understand disease biochemistry and identify biochemical markers of disease. Sample preparation methods must be reproducible, sensitive (high metabolite and lipid yield), and ideally rapid. We evaluated three biphasic methods for polar and nonpolar compound extraction (chloroform/methanol/water, dichloromethane/methanol/water, and methyl tert-butyl ether [MTBE]/methanol/water), a monophasic method for polar compound extraction (acetonitrile/methanol/water), and a monophasic method for nonpolar compound extraction (isopropanol/water). All methods were applied to mammalian heart, kidney, and liver tissues. Polar extracts were analyzed by hydrophilic interaction chromatography (HILIC) ultrahigh-performance liquid chromatography-mass spectrometry (UHPLC-MS) and nonpolar extracts by C18 reversed-phase UHPLC-MS. Method reproducibility and yield were assessed using multiple annotated endogenous compounds (putatively and MS/MS annotated). Monophasic methods had the highest yield and high reproducibility for both polar (positive ion median relative standard deviation (RSD) less then 18%; negative ion median RSD less then 28%) and nonpolar (positive and negative ion median RSD less then 15%) extractions for heart, kidneys, and liver. The polar monophasic method extracted higher levels of lipid than biphasic polar extractions, and these lipids caused minimal detection suppression for other compounds during HILIC UHPLC-MS. The nonpolar monophasic method had similar or greater detection responses of all detected lipid classes compared to biphasic methods (including increased phosphatidylinositol, phosphatidylserine, and cardiolipin responses). Monophasic methods are quicker and simpler than biphasic methods and are therefore most suited for future automation.We investigate the mechanisms of energy transfer in Mn2+-doped ethylammonium lead bromide (EA2PbBr4Mn2+), a two-dimensional layered perovskite (2DLP), using cryogenic optical spectroscopy. At temperature T > 120 K, photoluminescence (PL) is dominated by emission from Mn2+, with complete suppression of band edge (BE) emission and self-trapped exciton (STE) emission. However, for T less then 120 K, in addition to Mn2+ emission, PL is observed from BE and STEs. Data further reveal that for 20 K less then T less then 120 K, STEs form the most dominant routes in assisting energy transfer (ET) from 2DLP to Mn2+ dopants. However, at higher Mn2+ concentration, higher activation energies indicate defect states come into play, successfully competing with STEs for ET both from BE to STE states and from STE to Mn2+. Finally, using polarization-resolved spectroscopy, we demonstrate optical spin orientation of the Mn2+ ions via ET from 2DLP excitons at zero magnetic field. Our results reveal fundamental insights on the interactions between quantum confined charge carriers and dopants in organometal halide perovskites.Understanding the degradation mechanisms of organic cations under basic conditions is extremely important for the development of durable alkaline energy conversion devices. Cations are key functional groups in alkaline anion exchange membranes (AAEMs), and AAEMs are critical components to conduct hydroxide anions in alkaline fuel cells. Previously, we have established a standard protocol to evaluate cation alkaline stability within KOH/CD3OH solution at 80 °C. Herein, we are using the protocol to compare 26 model compounds, including benzylammonium, tetraalkylammonium, spirocyclicammonium, imidazolium, benzimidazolium, triazolium, pyridinium, guanidinium, and phosphonium cations. The goal is not only to evaluate their degradation rate, but also to identify their degradation pathways and lead to the advancement of cations with improved alkaline stabilities.A quadrupole ion trap (QIT) mass spectrometer has been modified and coupled with tunable laser excitation and highly sensitive fluorescence detection systems to perform fluorescence studies on mass-selected ions. Gaseous ions, generated using nanoelectrospray ionization (nano-ESI), are trapped in the QIT that allows optical access for laser irradiation. The emitted fluorescence is collected from a 5.0 mm diameter hole drilled into the ring electrode of the QIT and is directed toward the detection setup. Due to the small inner diameter (7.07 mm) of the ring electrode and a relatively large opening for fluorescence collection, a fluorescence collection efficiency of 2.3% is achieved. LY2780301 datasheet After some losses in transmission, around 1.8% of the emitted fluorescence reaches the detectors, more than any other similar instrument reported in the literature. This improved fluorescence collection translates to a much shorter measurement time for a fluorescence signal. Another key feature of this setup is the ability to perform a variety of fluorescence experiments on trapped ions including excitation and emission spectroscopy, lifetime measurement, and ion imaging. The capabilities of the instrument are demonstrated by measuring fluorescence spectra of dyes and biomolecules labeled with dyes in a range of different excitation and emission wavelengths, quantum yields, m/z, and different polarities. A fluorescence lifetime measurement and ion image of trapped rhodamine 6G cations are also shown. With a wide array of functionality and high fluorescence detection performance, this setup provides an opportunity to study biomolecular structures and photophysics of fluorophores in well-controlled environments.

Autoři článku: Kentoakley0367 (Gilliam Livingston)