Termansensanders1648
As this technique requires only 10 mg of the sample, it may be very useful in the routine clinical settings. The second application is for in vitro medical diagnostics where human blood serum is measured. The ability to measure fluid samples is also valuable in various biological experiments where a sufficient volume of sample for conventional analytical techniques cannot be provided. The third application leans toward the direct application of probe needles in living animals, where we can obtain real-time dynamics of metabolites or drugs in specific organs. In each application, we can infer the molecules that have been detected by MS or use artificial intelligence to obtain a medical diagnosis.Label-free impedance-based assays are increasingly used to non-invasively study ligand-induced GPCR activation in cell culture experiments. The approach provides real-time cell monitoring with a device-dependent time resolution down to several tens of milliseconds and it is highly automated. However, when sample numbers get high (e.g., dose-response studies for various different ligands), the cost for the disposable electrode arrays as well as the available time resolution for sequential well-by-well recordings may become limiting. Therefore, we here present a serial agonist addition protocol which has the potential to significantly increase the output of label-free GPCR assays. selleck chemicals Using the serial agonist addition protocol, a GPCR agonist is added sequentially in increasing concentrations to a single cell layer while continuously monitoring the sample's impedance (agonist mode). With this serial approach, it is now possible to establish a full dose-response curve for a GPCR agonist from just one single cell layer. The serial agonist addition protocol is applicable to different GPCR coupling types, Gq Gi/0 or Gs and it is compatible with recombinant and endogenous expression levels of the receptor under study. Receptor blocking by GPCR antagonists is assessable as well (antagonist mode).Pseudomonas aeruginosa (P. aeruginosa) is a major nosocomial pathogen of increasing relevance to human health and disease, particularly in the setting of chronic wound infections in diabetic and hospitalized patients. There is an urgent need for chronic infection models to aid in the investigation of wound pathogenesis and the development of new therapies against this pathogen. Here, we describe a protocol that uses delayed inoculation 24 hours after full-thickness excisional wounding. The infection of the provisional wound matrix present at this time forestalls either rapid clearance or dissemination of infection and instead establishes chronic infection lasting 7-10 days without the need for implantation of foreign materials or immune suppression. This protocol mimics a typical temporal course of post-operative infection in humans. The use of a luminescent P. aeruginosa strain (PAO1lux) allows for quantitative daily assessment of bacterial burden for P. aeruginosa wound infections. This novel model may be a useful tool in the investigation of bacterial pathogenesis and the development of new therapies for chronic P. aeruginosa wound infections.An abdominal aortic aneurysm (AAA) is defined as a localized dilation of the abdominal aorta that exceeds the maximal intraluminal diameter (MILD) by 1.5 times of its original size. Clinical and experimental studies have shown that small aneurysms may rupture, while a subpopulation of large aneurysms may remain stable. Thus, in addition to the measurement of intraluminal diameter of the aorta, knowledge of structural traits of the vessel wall may provide important information to assess the stability of the AAA. Aortic stiffening has recently emerged as a reliable tool to determine early changes in the vascular wall. Pulse propagation velocity (PPV) along with the distensibility and radial strain are highly useful ultrasound-based methods relevant for assessing aortic stiffness. The primary purpose of this protocol is to provide a comprehensive technique for the use of ultrasound imaging system to acquire images and analyze the structural and functional properties of the aorta as determined by MILD, PPV, distensibility and radial strain.Electrowetting is the effect by which the contact angle of a droplet exposed to a surface charge is modified. Electrowetting-on-dielectric (EWOD) exploits the dielectric properties of thin insulator films to enhance the charge density and hence boost the electrowetting effect. The presence of charges results in an electrically induced spreading of the droplet which permits purposeful manipulation across a hydrophobic surface. Here, we demonstrate EWOD-based protocol for sample processing and detection of four categories of antigens, using an automated surface actuation platform, via two variations of an Enzyme-Linked Immunosorbent Assay (ELISA) methods. The ELISA is performed on magnetic beads with immobilized primary antibodies which can be selected to target a specific antigen. An antibody conjugated to HRP binds to the antigen and is mixed with H2O2/Luminol for quantification of the captured pathogens. Assay completion times of between 6 and 10 min were achieved, whilst minuscule volumes of reagents were utilized.Animal welfare assessment techniques try to take into consideration the specific needs and wants of the animal in question. Providing enrichment (the addition of physical objects or conspecifics in the housing environment) is often a way to give captive animals the opportunity to choose who or what they interact with and how they spend their time. A fundamental component of the aquatic environment that is often overlooked in captivity, however, is the ability for the animal to choose to engage in physical exercise. For many animals, including fish, exercise is an important aspect of their life history, and is known to have many health benefits, including positive changes in the brain and behavior. Here we present a method for assessing habitat preferences in captive animals. The protocol could easily be adapted to look at a variety of environmental factors (e.g., gravel versus sand as a substrate, plastic plants versus live plants, low flow versus high flow of water) in different aquatic species, or for use with terrestrial species.