Mccormickhinson1189
ydrogel-based catheter devices with expanding inner-diameters for applications in medical care.Nanomaterials, as an active ingredient, have been widely deployed in various science and technological applications with zinc and titanium oxides nanoparticles being commonly applied in sunscreens. On similar lines, cerium oxide nanoparticles (CeO2-NPs) were synthesized using Musa sapientum peel extract, to investigate its cytotoxic effects, UV protection and photocatalytic activity. The synthesized nanoparticles were identified through Raman, Powder X-ray Diffraction (PXRD), Fourier-Transform Infrared spectroscopy (FT-IR), Transmission Electron Microscopy (TEM), Field Emission Scanning Electron Microscopy (FESEM) and Energy-Dispersive Spectroscopy (EDX). FESEM results showed that the size of synthesized nanoparticles is in the range 4-13 nm. Their cytotoxic activity revealed a non-toxic behavior in concentrations below 500 μg/mL on lung (A549) cell lines. The Sun protection factor (SPF) was estimated approximately ~ 40 for synthesized CeO2-NPs. The survey of photocatalytic activity showed that synthesized nanoparticles can remove 81.7% of AO7 in 180 min under visible light.The foundation of managing excess nutrients in river is the identification of key physical processes and the control of decisive influencing factors. The existing studies seldom consider the influence of rainfall-runoff relationship and only focus on a few anthropogenic activities and natural attributes factors. To address this issue, a comprehensive set of influencing factors including rainfall-runoff relationship (represented by runoff coefficient), basic physical and chemical parameters of water quality, land use types, landscape patterns, topography, and socioeconomic development was constructed in this study. M-K test and cluster analysis were conducted to identify the temporal mutation and spatial clustering characteristics of NH3-N and TP in Huangshui River basin, respectively. Partial least squares regression was used to elucidate the linkages between water contaminants and the factors. As shown in the results, the temporal mutations of NH3-N and TP were obvious in the middle reaches, with 4 out of 7 ults of this study can provide theoretical basis and technical support for the control and management of nitrogen and phosphorus pollution in upper reaches of rivers.Fifteen native luminescent bacteria were isolated from the Gulf of Thailand, and their sensitivity for the detection of toxicity of crude oil and its aromatic components was investigated. SS-31 Of these isolates, Vibrio campbellii strain FS5 was one of the two most highly inhibited bacteria at all crude oil concentrations. This bacterium showed a decrease in luminescence intensity of between 10.7 and 80.2% after a 15-min exposure to 0.0001-10 mg/L of crude oil. The degree of bioluminescence inhibition increased with increasing concentrations of crude oil. The presence of crude oil at all concentrations had negative effects on the log bioluminescence per log number of viable cells after 15- to 105-min exposure. About 10 to 100 times, lower half maximal effective concentration (EC50) values were observed for polycyclic aromatic hydrocarbons (PAHs) than those for benzene, toluene, ethylbenzene, and xylene (BTEX). In the presence of each individual BTEX and PAH, the bioluminescence inhibition increased with increasing exposure time (1-32 h). This indigenous bacterium can be used as a simple and general indicator of oil contamination and its impact on coastal waters as well as for assessing potential toxicity during oil bioremediation.Two-dimensional Mo2C/Mo2N composites were synthesized by high temperature ball milling and used as support materials for fabricating a chlorpyrifos (CPF) aptasensor. Gold nanoparticles (Au NPs) were electrodeposited on the surface of a Mo2C/Mo2N-modified electrode to connect with the ferrocene (Fc) probe via Au-S bonds. The Fc probe can hybridize with the aptamer probe to form a double-stranded structure. The addition of CPF made the double strands melt and the Fc probe approached the surface of the electrode, thereby resulting in amplification of the electrochemical response. The current response of the aptasensor for detecting CPF in solutions linearly varied from 0 to 400 ng mL-1 (with a maximum at 0.98 V vs. Ag/AgCl). The Au NPs/Mo2C/Mo2N composites exhibited satisfactory electrochemical behavior due to their excellent electrical conductivity and large surface area. This ultrasensitive aptasensor showed a low limit of detection of 0.036 ng mL-1. It was applied to determine CPF in real samples with acceptable recoveries from 94.7 to 116.7%, and the relative standard deviation was from 2.57 to 7.08%.Graphical abstract Schematic diagram of the manufacturing process of the aptasensor. Electrochemical aptasensor based on Mo2C/Mo2N/Au NP composites show excellent performance in detecting CPF.
Diagnosis and treatment of insertional tendinopathy of the Achilles tendon (IAT) remains a challenge. The aim of this study was to assess the influence of pre-operative radiological pathologies on the patient-reported outcomes following open debridement of all pathologies for IAT.
In this IRB-approved retrospective correlation and comparative study, patients with pre-operative imaging were identified from the authors' retrospective IAT database comprising of 118 patients. All were treated by a standardized surgical treatment strategy utilizing a midline, transachillary approach and debridement of all pathologies. A total of fifteen radiologic parameters were measured on radiographs (RX) and MRI. The patient-reported outcomes were assessed using the Victorian Institute of Sport Assessment-Achilles questionnaire (VISA-A-G) and the general health questionnaire SF-12 at a minimum follow-up of 12months. The data are presented as mean ± SD (95% CI).
88 patients (74.6%) with an average age of 50 ± 12 (47-52) years were included. Radiographs were available in 68 patients and MRI in 53. The mean follow-up was 3.8 ± 1.9 (3.4-4.3) years. The overall VISA-A-G was 81 ± 22 (77-86), the SF-12 PCS 54 ± 7 (52-55), and the SF-12 MCS 52 ± 9 (50-54) points. None of the assessed radiological parameters had a significant influence on the patient-reported outcome following surgical treatment for IAT.
In this retrospective correlation study, no significant association was found between preoperative radiographic and MRI radiologic parameters for IAT and postoperative patient-reported outcomes (VISA-A-G and SF-12).
In this retrospective correlation study, no significant association was found between preoperative radiographic and MRI radiologic parameters for IAT and postoperative patient-reported outcomes (VISA-A-G and SF-12).