Background Investigation of hemostasis is problematic when patients are on anticoagulant therapy. Rivaroxaban especially causes substantial interference, extending many clot-based tests, thereby leading to false positive or negative events. In particular, rivaroxaban affects some assays for activated protein C resistance (APCR). Methods We assessed, in an international setting, cross laboratory (n = 31) testing using four samples to evaluate rivaroxaban induced interference in APCR testing, and whether this interference could be neutralised. The samples comprised (A) pool of normal plasma (APCR-negative control); (B) this normal pool spiked with rivaroxaban (200 ng/mL) to create rivaroxaban-induced interference (potential 'false' positive APCR event sample); (C) the rivaroxaban sample subsequently treated with a commercial direct oral anticoagulant 'DOAC-neutraliser' (DOAC Stop), or (D) treated with andexanet alfa (200 μg/mL). Testing was performed blind to sample type. Results The rivaroxaban-spiked sample generated false positive APCR results for some, but unexpectedly not most APCR-tests. The sample treated with DOAC Stop evidenced a correction in the rivaroxaban-affected APCR assays, and did not otherwise adversely affect the rivaroxaban 'unaffected' APCR assays. HDAC inhibitor The andexanet alfa-treated sample did not evidence correction of the false positive APCR, and instead unexpectedly exacerbated false positive APCR status with many tests. Conclusions DOAC Stop was able to neutralise any APCR interference induced by rivaroxaban. In contrast, andexanet alfa did not negate such interference, and instead unexpectedly created more false-positive APCR events.Background Gaucher disease (GD), caused by a deficiency in acid β-glucosidase, leads to the accumulation of glucosylsphingosine (GluSph), which has been used as a powerful biomarker for the diagnosis and follow-up of GD. Our aim was to perform the first retrospective study of GluSph in Spanish patients, analyzing its relationship with classical biomarkers and other parameters of disease and its utility regarding treatment monitoring. Methods Classical biomarkers were evaluated retrospectively by standard methods in a total of 145 subjects, including 47 GD patients, carriers, healthy controls and patients suffering from other lysosomal lipidoses. GluSph was also measured using a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method developed as part of the present study. Results The optimized method presented intra- and inter-assay variations of 3.1 and 11.5%, respectively, overall recovery higher than 96% and linearity up to plasma concentrations of 1000 ng/mL with 100% specificity and sensitivity. Only GD patients displayed GluSph levels above 5.4 ng/mL at diagnosis and this was significantly correlated with the classical biomarkers chitotriosidase (r = 0.560) and the chemokine CCL18/PARC (CCL18/PARC) (ρ = 0.515), as well as with the Spanish magnetic resonance imaging index (S-MRI, r = 0.364), whereas chitotriosidase correlated with liver volume (r = 0.372) and CCL18/PARC increased in patients with bone manifestations (p = 0.005). GluSph levels decreased with treatment in naïve patients. Conclusions Plasma GluSph is the most disease-specific biomarker for GD with demonstrated diagnostic value and responsiveness to therapy. GluSph in the present series of patients failed to demonstrate better correlations with clinical characteristics at onset than classical biomarkers.BACKGROUND Multimorbidity is a global health problem that is usually associated with polypharmacy, which increases the risk of potentially inappropriate prescribing (PIP). PIP entails higher hospitalization rates and mortality and increased usage of services provided by the health system. Tools exist to improve prescription practices and decrease PIP, including screening tools and explicit criteria that can be applied in an automated manner. OBJECTIVE This study aimed to describe the prevalence of PIP in primary care consultations among patients aged 65-75 years with multimorbidity and polypharmacy, detected by an electronic clinical decision support system (ECDSS) following the 2015 American Geriatrics Society Beers Criteria, the European Screening Tool of Older Person's Prescription (STOPP), and the Screening Tool to Alert doctors to Right Treatment (START). METHODS This was an observational, descriptive, cross-sectional study. The sample included 593 community-dwelling adults aged 65-75 years (henceforth c using the 2015 Beers Criteria. Being a woman (odds ratio [OR] 1.43, 95% CI 1.01-2.01; P=.04), taking a greater number of medicines (OR 1.25, 95% CI 1.14-1.37; P less then .001), working in the primary sector (OR 1.91, 95% CI 1.25-2.93; P=.003), and being prescribed drugs for the central nervous system (OR 3.75, 95% CI 2.45-5.76; P less then .001) were related to a higher frequency of PIP. CONCLUSIONS There is a high prevalence of PIP in primary care as detected by an ECDSS in community-dwelling young seniors with comorbidity and polypharmacy. The specific PIP criteria defined by this study are consistent with the current literature. This ECDSS can be useful for supervising prescriptions in primary health care consultations. ©Eloisa Rogero-Blanco, Juan A López-Rodríguez, Teresa Sanz-Cuesta, Mercedes Aza-Pascual-Salcedo, M Jose Bujalance-Zafra, Isabel Cura-González, MultiPAP Group. Originally published in JMIR Medical Informatics (http//medinform.jmir.org), 01.03.2020.Given that the effectiveness of interstitial hyperthermia for cancer treatment is related to the temperature achieved during the ablation process, there is a need for an accurate understanding of the required temperature distribution which is affected by the physical shape and form of tumours. Although a maximum peak temperature value and minimum backward heating are desired, the temperature distribution needs to be not only high but also uniformly extended over a section instead of at one peak point, especially when a roughly oval-shaped tumour is aligned with the antenna. In this case, achieving a high temperature peak destroys only the central cancerous cells after the first minutes of ablation, leaving the cells on the side alive. In this paper, a complex model was extended for the study of the heat distribution of an antenna over a porous liver composed of blood, cancerous cells, and normal tissue. Three different types of antenna were analysed single-slot, double-slot, and dipole-tip. A novel structure made up of the single-slot antenna with a micron cut, named the micro-cut slot (MCS) antenna, was proposed and analysed.

Autoři článku: Skouheath6640 (Bernstein Werner)