Beantrevino3522

Z Iurium Wiki

Verze z 7. 11. 2024, 15:38, kterou vytvořil Beantrevino3522 (diskuse | příspěvky) (Založena nová stránka s textem „ich seems efficacious in reducing interstage Norwood deaths. A significant reduction of longitudinal strain after Norwood stage 1 is a strong predictor of…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

ich seems efficacious in reducing interstage Norwood deaths. A significant reduction of longitudinal strain after Norwood stage 1 is a strong predictor of poor outcome. © The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.OBJECTIVES We sought to compare the effects of conventional wire cerclage with that of the band and plate fixation of the sternum. METHODS A parallel randomized open-label trial with 11 allocation ratio compared healing after adult cardiac surgery using 'figure-of-8' stainless steel wire cerclage or a band and plate system (plates). The primary end point was maximal sternal edge displacement during active coughing of ≥2 mm in ≥2 of 4 sites measured with ultrasound by 2 assessors blinded to the other at 6 weeks postoperatively. Secondary end points at 12 weeks included ultrasound assessment, computed tomography (CT) scan and multidimensional assessment of quality of recovery using the Postoperative Quality of Recovery Scale. RESULTS Of 50 patients, 26 received plates and 24 wires. Two patients died and 1 withdrew consent leaving 25 plates and 22 wires for primary end point analysis. Operations included 37 coronary, 5 valve and 8 combined coronary and valve procedures. At 6 weeks, less sternal movement was observed in patients with plates than those with wires, 4% (1/25) vs 32% (7/22), P = 0.018. Agreement between observers was high, kappa = 0.850. At 12 weeks, less ultrasound motion was seen in patients with plates, 0% (0/23) than those with wires, 25% (5/20), P = 0.014. Recovery from pain was higher for patients with plates 92% (22/24) than those with wires 67% (14/21), P = 0.004. CT bone edge separation was less for plates 38% (9/24) than wires 71% (15/21), P = 0.036. CT mild bone synthesis or greater was similar between patients with plates 21% (5/24) and wires 14% (3/21), P = 0.71. CONCLUSIONS Patients receiving the band and plate system had significantly less sternal edge motion than those receiving wires, 6 and 12 weeks after cardiac surgery and experienced less pain. CLINICAL TRIAL REGISTRATION clinicaltrials.gov NCT03282578. © The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.OBJECTIVES We evaluated the operative and long-term outcomes of the frozen elephant trunk (FET) technique for acute type A aortic dissection. METHODS This study evaluated 426 consecutive patients who underwent aortic repair for acute type A aortic dissection from June 2007 to December 2018 at our centre. Of these, 139 patients underwent total arch replacement with FET (FET group), and 287 underwent other procedures (no FET group). Ninety-two patients in the FET group were matched to 92 patients in the no FET group by using propensity score matching analysis. RESULTS Thirty-day mortality and neurological dysfunction were not significantly different between the FET and no FET groups (1.4% vs 2.4%, P = 0.50 and 5.0% vs 6.3%, P = 0.61, respectively). Long-term survival was better in the FET group than in the no FET group (P = 0.008). Freedom from distal thoracic reintervention was similar in the FET and no FET groups (P = 0.74). In the propensity-matched patients, freedom from aortic-related death was better in the FET group than in the no FET group (P = 0.044). CONCLUSIONS Operative outcomes showed no significant difference between the 2 groups. FET contributes to better long-term survival in patients with acute type A aortic dissection. © The Author(s) 2020. Siremadlin Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.OBJECTIVES Bentall procedure is the gold standard for aortic root pathologies when valve repair is not feasible. The development of durable bioprosthetic valves and improved vascular conduits allowed the implementation of bioprosthetic composite grafts; hereby, we performed a retrospective analysis of long-term follow-up of Bentall procedure using the Valsalva graft and the Perimount Magna Ease prosthesis. METHODS From June 2000 to March 2019, 309 patients received an aortic root and valve replacement with a bioprosthetic composite graft. The mean age was 69 ± 6.9 years, and the majority were men (88%); most of them were affected by aortic stenosis (86%) and the mean aortic root diameter was 48.6 ± 5.5 mm. RESULTS Freedom from cardiac death was 76.8% [confidence interval (CI) 32.5-94.0] at 16 years. Freedom from thromboembolism, haemorrhage, structural valve deterioration and infective endocarditis was 98.2% (CI 96.0-98.9), 95.2% (CI 87.1-98.2), 87.5% (CI 63.2-97.1) and 79.6% (CI 45.3-95.6) at 16 years, respectively. Freedom from reoperation was 74.7% (CI 41.9-90.6). CONCLUSIONS These data indicate that, in experienced centres, the Bentall procedure is a safe and effective intervention. This is the first long-term follow-up that analyses the results after implantation of a composite graft made with the Perimount Magna Ease aortic valve and the Valsalva graft. © The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.Despite efforts taken by the Government of India, mothers and newborns are excluded from the maternal and child health services, especially those in poorer and weaker sections of the society. Hence, we have utilized the most recent National Family Health Survey (NFHS-4) data to assess the socio-economic inequities in antenatal care (ANC), intranatal care and postnatal care (PNC) coverage for mothers and newborns in India. We have analysed the NFHS-4 data gathered from the Demographic Health Survey programme. Stratification and clustering in the sample design were accounted for using 'svyset' command. Point estimates were reported as proportions with 95% confidence interval. The concentration curve and index were used to represent the socio-economic inequities. Theil index was computed to report inequities across geographical regions and place of residence. In total, 190 797 women who had at least one live birth in the preceding 5 years were included. About 52.1% of women had at least four ANC visits and 81.4% had institutional delivery.

Autoři článku: Beantrevino3522 (McDermott Fulton)