Straarupwise1739

Z Iurium Wiki

Verze z 17. 10. 2024, 02:29, kterou vytvořil Straarupwise1739 (diskuse | příspěvky) (Založena nová stránka s textem „Pericardial effusion drainage in patients with significant pulmonary hypertension (PH) has been questioned because of hemodynamic collapse concern, mainly…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

Pericardial effusion drainage in patients with significant pulmonary hypertension (PH) has been questioned because of hemodynamic collapse concern, mainly because of right ventricular (RV) function challenging assessment. We aimed to assess RV function changes related to pericardiocentesis in patients with and without PH.

Consecutive patients with symptomatic moderate-to-large pericardial effusion who had either echocardiographic or clinical signs of cardiac tamponade and who underwent pericardiocentesis from 2013 to 2018 were included. RV speckle-tracking echocardiography analysis was performed before and after pericardiocentesis. Patients were stratified by significant PH (pulmonary artery systolic pressure [PASP] ≥50mmHg).

The study cohort consisted of 76 patients, 23 (30%) with PH. In patients with PH, both end-diastolic and end-systolic areas (EDA, ESA) increased significantly after pericardiocentesis (22.6±8.0cm

-26.4±8.4cm

, P=.01) and (15.9±6.3cm

-18.7±6.5cm

, P=.02), respectively. However, RV function indices including fractional area change (FAC 30.6±13.7%-29.1±8.8%, P=.61) and free-wall longitudinal strain (FWLS -16.7±6.7 to -15.9±5.0, P=.50) remained unchanged postpericardiocentesis. In contrast, in the non-PH group, after pericardiocentesis, EDA increased significantly (20.4±6.2-22.4±5.9 cm

, P=.006) but ESA did not (14.9±5.7 vs 15.0±4.6cm

, P=.89), and RV function indices improved (FAC 27.9±11.7%-33.1±8.5%, P=.003; FWLS -13.6±5.4 to -17.2±3.9%, P<.001).

Quantification of RV size and function can improve understanding of echocardiographic and hemodynamic changes postpericardiocentesis, which has the potential to guide management of PH patients with large pericardial effusion.

Quantification of RV size and function can improve understanding of echocardiographic and hemodynamic changes postpericardiocentesis, which has the potential to guide management of PH patients with large pericardial effusion.

This study aimed to assess the validity of diagnoses of congenital malformations (CMs) recorded in claims of a university hospital in Japan.

Congenital malformations were identified according to Code Q00-Q89 of the International Classification of Diseases, 10th revision. All the children who had been diagnosed with CMs based on their claims in 2015 and within 1 year from their birth month were selected for this study. The infants' medical records were considered as a gold standard. Positive predictive values (PPVs) for CMs were calculated.

This study included 227 infants who had a CM diagnosis in their claims. Based on the algorithms established by the Quebec Pregnancy Cohort study group, the PPV for any CM was 90.7% and that for major CMs (MCMs) was 91.5%. Concerning MCMs of specific organ systems, those of the circulatory system (PPV 85.1%) were the most frequent, followed by cleft lip and cleft palate (PPV 100.0%), and other CMs of the digestive system (PPV 96.4%). Based on the EUROCAT classification, the PPV for any MCM was 88.5%. Specific MCMs reported in ≥20 infants were ventricular septal defect (PPV 96.0%), patent ductus arteriosus (PPV 72.7%) and cleft lip with or without cleft palate (PPV 100.0%).

The PPVs for CMs in the Japanese administrative data were high enough to suggest that these data could be utilized for perinatal pharmacoepidemiological evaluations. The results were from a single center, and further validation studies are needed.

The PPVs for CMs in the Japanese administrative data were high enough to suggest that these data could be utilized for perinatal pharmacoepidemiological evaluations. The results were from a single center, and further validation studies are needed.Fluorenyl cations are textbook examples of 4π electron antiaromatic five-membered ring systems. So far, they were reported only as short-lived intermediates generated under superacidic conditions or by flash photolysis. Attempts to prepare a m-terphenyl acylium cation by fluoride abstraction from a benzoyl fluoride gave rise to an isolable 9-hydroxy fluorenyl cation that formed by an intramolecular electrophilic attack at a flanking mesityl group prior to a 1,2-methyl shift and proton transfer to oxygen.

A silver phosphate reference material (Ag

PO

) for the measurement of stable oxygen isotope compositions is much needed; however, it is not available from the authorities distributing reference materials. This study aims to fill this gap by calibrating a new Ag

PO

stable isotope comparison material produced by the University of Natural Resources and Life Sciences (BOKU).

Aliquots of Ag

PO

were distributed to four laboratories who frequently measure the δ

O value in Ag

PO

 ; the University of Natural Resources and Life Sciences (BOKU), the University of Western Australia (UWA), the University of Helsinki (UH), and the Helmholtz Centre for Environmental Research (UFZ). AG270 The instruments used to perform the measurements were high-temperature conversion elemental analysers coupled with continuous flow isotope ratio mass spectrometers. The working gas δ

O value was set to 0‰ and the normalization was done by a three-point linear regression using the reference materials IAEA-601, IAEA-602, and NBS127.

The mean δ

O value of the new BOKU Ag

PO

comparison material on the VSMOW-SLAP scale is 13.71‰ and the combined uncertainty is estimated as ±0.34‰. This estimated uncertainty is within the range typical for comparison materials of phosphates and sulphates. Consistent results from the different laboratories probably derived from similar instrumentation, and use of the same reference materials and normalization procedure. The matrix effect of the different reference materials used in this study was deemed negligible.

The BOKU Ag

PO

can be used as an alternative comparison material for stable oxygen isotope analysis and is available for stable isotope research laboratories to facilitate calibration.

The BOKU Ag3 PO4 can be used as an alternative comparison material for stable oxygen isotope analysis and is available for stable isotope research laboratories to facilitate calibration.

Autoři článku: Straarupwise1739 (Joseph Cormier)