Chaneyrosendal0139

Z Iurium Wiki

Verze z 7. 10. 2024, 12:22, kterou vytvořil Chaneyrosendal0139 (diskuse | příspěvky) (Založena nová stránka s textem „A specific sequence is recommended for filling blood tubes during blood collection to prevent erroneous test results due to carryover of additives. However…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

A specific sequence is recommended for filling blood tubes during blood collection to prevent erroneous test results due to carryover of additives. However, requirement of this procedure is still debatable. This study was aimed to investigate the potassium ethylenediaminetetraacetic acid (K-EDTA) contamination in blood samples taken after a tube containing the additive during routine workflow. The study was also carried out to examine the effect of order of draw on potassium results, regardless of K-EDTA contamination.

In 388 outpatients, to determine the probability of K-EDTA cross-contamination, blood was drawn sequentially into a serum tube, followed by a tube containing K-EDTA, and by another serum tube. In another 405 outpatients, to evaluate the effect of order of draw blood unrelated to K-EDTA contamination, two serum tube were successively collected. Potassium was measured on Cobas 6000 c501 analyser (Roche Diagnostic GmbH, Mannheim, Germany) by indirect ion selective electrode method.

Of paired samples collected before and after a K-EDTA tube, 24% had a potassium difference of above 0.3 mmol/L. However, no EDTA contamination was detected in these samples as well as 95% confidence intervals (CI) of limits of agreement for calcium were within the allowable error limits based on reference change values. Interestingly, of blood samples drawn successively, 24% had also a difference greater than 0.3 mmol/L for potassium.

Incorrect order of draw using closed blood collection system does not cause K-EDTA contamination, even in routine workflow. However, regardless of K-EDTA contamination, order of draw has significant influence on the potassium results.

Incorrect order of draw using closed blood collection system does not cause K-EDTA contamination, even in routine workflow. However, regardless of K-EDTA contamination, order of draw has significant influence on the potassium results.

Total bilirubin tests are highly demanded in clinical laboratories. Since icteric index (I-index) has zero cost, we aimed to evaluate its clinical utility and cost-effectiveness to determine if total bilirubin is necessary to be tested. We took into account if haemolysis could interfere to icteric index determination.

Retrospectively we reviewed I-index results in two cohorts (43,372 and 8507 non-haemolysed and haemolysed samples, respectively). All determinations were done using Alinity c chemistry analysers (Abbott Diagnostics). ALK inhibition Receiver operating characteristic (ROC) curve was used to determine the optimal index cut-off to discriminate between normal and abnormal bilirubin concentration (20.5 µmol/L).

The ROC curve analysis suggested 21.4 µmol/L as the optimal I-index cut-off but differences in sensitivity and specificity were detected between patient derivation. For rejecting purpose, 15.4 µmol/L and 17.1 µmol/L I-index thresholds were selected based on patient derivation (inpatients and emergency room; and primary care and outpatients, respectively) with 97% sensitivity and 0.25% false negative results. Sensitivity was much lower in haemolysed samples. We selected 34.2 µmol/L I-index as threshold to detect hyperbilirubinemia with 99.7% specificity and 0.26% false positive results, independent of haemolysis. With the icteric index cut-offs proposed, we would save 66% of total bilirubin requested and analyse total bilirubin in around 2% of samples without total bilirubin requested.

This study supports the use of I-index to avoid bilirubin determination and to identify patients with hyperbilirubinemia. This work considers that the economic and test savings could help to increase the efficiency in clinical laboratories.

This study supports the use of I-index to avoid bilirubin determination and to identify patients with hyperbilirubinemia. This work considers that the economic and test savings could help to increase the efficiency in clinical laboratories.

An appropriate management of anaemia laboratory tests is crucial for a correct diagnosis and treatment. A non-sequential "shotgun" approach (where every anaemia related test is ordered) causes workload and cost increases and could be potentially harmful. We have implemented a Decision Support System through our laboratory information system (LIMS) based on reflexive algorithms and automatic generation of interpretative reports specifically in diagnosis of anaemia for primary care patients.

When a request contained an "Anaemia Suspicion Study" profile, more than twenty automatic reflexive rules were activated in our LIMS based upon laboratory results. These rules normally involved the addition of reflexive tests. A final report was automatically generated for each interpretation which was always reviewed for their validity by two staff pathologists. We measured the impact of this system in the ordering of most common anaemia related tests and if a proper treatment was established based on the interpretive report.

From all the studies performed, only 12% were positive being "iron deficiency" and "anaemia of chronic disease" the most frequent causes, 62% and 17%, respectively. Proper treatment was established in 88% of these anaemic patients. Total iron, transferrin, ferritin, folate and vitamin B12 demand decreased substantially after implementation representing a cost reduction of 40% only for these five tests.

Our system has easily improved patient outcomes, advising on individual clinical cases. We have also noticeably reduced the number of over-requested tests and laboratory costs.

Our system has easily improved patient outcomes, advising on individual clinical cases. We have also noticeably reduced the number of over-requested tests and laboratory costs.

The aim of the present study was to determine and compare the concentration of hyaluronic acid (HA) in rheumatoid arthritis (RA), systemic sclerosis (SSc) and systemic lupus erythematosus (SLE), and its correlation with parameters of disease activity and duration. The hypothesis was that HA should be increased in rheumatic diseases. We also expected that HA could be a marker of disease activity and inflammation in some of these diseases.

The study group comprised 149 patients with RA, SSc and SLE hospitalized in the Department of Rheumatology and Internal Diseases, Medical University of Bialystok (Bialystok, Poland) and 30 healthy controls. The concentrations of HA, C-reactive protein (CRP) and rheumatoid factor (RF) were measured using Architect ci8200; haemoglobin, platelets on Sysmex XS-800i; and erythrocyte sedimentation rate (ESR) on Sediplus S 2000 analysers. Statistical analysis was performed using Statistica 13.3 PL.

Hyaluronic acid was increased in RA, SLE and SSc when compared to controls (P < 0.

Autoři článku: Chaneyrosendal0139 (Keegan Vilhelmsen)