Holmeskock0625

Z Iurium Wiki

Verze z 29. 9. 2024, 20:09, kterou vytvořil Holmeskock0625 (diskuse | příspěvky) (Založena nová stránka s textem „Background and study aims  Hemostatic powders have emerged recently to treat upper gastrointestinal bleeding (UGIB). Previously, we developed a novel sel…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

Background and study aims  Hemostatic powders have emerged recently to treat upper gastrointestinal bleeding (UGIB). Previously, we developed a novel self-propelling thrombin powder (SPTP) that effectively manages external pulsatile arterial bleed without compression, by effervescing and carrying thrombin into the wound. Here, we tested if SPTP, sprayed endoscopically, can manage severe UGIB in a live porcine model. Materials and methods  Anesthetized pigs underwent laparotomy to insert the gastroepiploic vascular bundles into the stomach lumen via a gastrotomy. Bleeding was initiated endoscopically in the stomach by needle knife. SPTP was delivered to the site of bleeding from a CO 2 -powered spray device using a 7 FR catheter. Successful primary hemostasis, time to hemostasis, and the mass of SPTP delivered were measured. Results  Hemostasis was achieved at all bleeding sites using SPTP. Mean time to hemostasis was 4.2 ± 0.9 minutes (mean ± standard error of the mean, n = 12). The average mass of SPTP delivered was 2.4 ± 0.6 g. Conclusions  In this pilot study, SPTP successfully stopped 12 cases of severe UGIB, demonstrating early promise asa novel hemostatic powder.Background and study aims  A novel endoscopic optical diagnosis classification system (SIMPLE) has recently been developed. This study aimed to evaluate the SIMPLE classification in a clinical cohort. Patients and methods  All diminutive and small colorectal polyps found in a cohort of individuals undergoing screening, diagnostic, or surveillance colonoscopies underwent optical diagnosis using image-enhanced endoscopy (IEE) and the SIMPLE classification. The primary outcome was the agreement of surveillance intervals determined by optical diagnosis compared with pathology-based results for diminutive polyps. Secondary outcomes included the negative predictive value (NPV) for rectosigmoid adenomas, the percentage of pathology exams avoided, and the percentage of immediate surveillance interval recommendations. Analysis of optical diagnosis for polyps ≤ 10 mm was also performed. Results  399 patients (median age 62.6 years; 55.6 % female) were enrolled. For patients with at least one polyp ≤ 5 mm undergoing optical diagnosis, agreement with pathology-based surveillance intervals was 93.5 % (95 % confidence interval [CI] 91.4-95.6). The NPV for rectosigmoid adenomas was 86.7 % (95 %CI 77.5-93.2). When using optical diagnosis, pathology analysis could be avoided in 61.5 % (95 %CI 56.9-66.2) of diminutive polyps, and post-colonoscopy surveillance intervals could be given immediately to 70.9 % (95 %CI 66.5-75.4) of patients. For patients with at least one ≤ 10 mm polyp, agreement with pathology-based surveillance intervals was 92.7 % (95 %CI 89.7-95.1). NPV for rectosigmoid adenomas ≤ 10 mm was 85.1 % (95 %CI CI 76.3-91.6). Conclusions  IEE with the SIMPLE classification achieved the quality benchmark for the resect and discard strategy; however, the NPV for rectosigmoid polyps requires improvement.Background and study aims  There has been little evidence assessing the prevalence of musculoskeletal disorders (MSDs) among endoscopists performing recent diagnostic and therapeutic endoscopic procedures requiring prolonged procedural times. We evaluated the prevalence and identified the risk factors for developing MSDs, focusing on procedural time. Methods  An electronic survey of endoscopists (n = 213) employed at the Nagoya University Hospital and its affiliated hospitals was developed by a multidisciplinary group.  Results  Of the 110 endoscopists (51.6 %) who responded to the survey, eighty-seven endoscopists (79.1 %) had experienced endoscopy-related MSDs during the previous 1 year, and 49 endoscopists (44.5 %) had experienced these MSDs during the previous week. Nineteen endoscopists (17.3 %) reported absence from work due to severe MSDs. The most frequent sites of MSDs were neck, low back, and shoulders. Logistic regression analyses showed that longer upper endoscopic submucosal dissection ESD, (odds ratio 5.7; 95 %CI 1.3-25.0), lower ESD (odds ratio 4.9; 95 %CI 1.1-22.0), and lower gastrointestinal treatment (odds ratio 5.6; 95 %CI 2.3-13.3) were significantly associated with the development of MSDs in the low back area. Moreover, longer lower ESD (odds ratio 5.0; 95 % CI 1.2-20.2) was a risk factor for symptoms in the left shoulder. Conclusion  This study suggests a correlation between the volume of therapeutic endoscopic procedures including ESD and the risk of MSDs mainly low back area and left shoulder. Managing monthly total endoscopic time, in light of organizational ergonomics, could contribute to minimizing such risks of endoscopy-related MSDs.Background and study aims  Endoscopic biliary sphincterotomy (EBS) related-bleeding is a common adverse event related to endoscopic retrograde cholangiopancreatography (ERCP). Traditionally, endoscopic modalities such as epinephrine injection, cauterization, and balloon tamponade have been used for management. Recently, use of a fully covered self-expandable metal stent (FCSEMS) to manage EBS-related bleeding has gained popularity. However, data regarding its use are limited to small case series. Therefore, we aimed to evaluate the safety and efficacy of FCSEMS placement for the treatment of EBS-related bleeding. Patients and methods  All patients referred to our center from October 2014 to November 2019 who had an FCSEMS placed for EBS-related bleeding were included. FCSEMS was placed either for primary control of bleeding or after failure of other traditional endoscopic hemostasis techniques at the discretion of the endoscopist. Data was collected regarding patient demographics, procedural characteristics, clinical and technical success rates of FCSEMS, as well as adverse events. Results  A total of 97 patients underwent placement of FCSEMS for EBS-related bleeding, of which 76.3 % had immediate bleeding and 23.7 % had delayed bleeding. Mean age was 67.2 years and 47.4 % were males. Seven patients who had immediate EBS-related bleeding at index ERCP underwent other endoscopic therapies prior to placement of FCSEMS for rebleeding. The technical success rate for FCSEMS placement was 100 % and the rebleeding rate was 6.2 %. Four patients with FCSEMS placement developed pancreatitis and four had stent migration. Conclusions  Our findings suggest that FCSEMS is a highly effective treatment modality for managing EBS-related bleeding and has an acceptable safety profile.Background and study aims  Endoscopic resection of duodenal neuroendocrine tumors (DNETs) remains controversial, and its indications are still unclear. This study aimed to evaluate short-term outcomes of a newly developed endoscopic muscularis resection (EMR) method that utilizes an over-the-scope clip (OTSC), termed EMRO, for treating DNETs. Patients and methods  In total, 13 consecutive patients with 14 small (≤ 10 mm) DNETs who underwent EMRO from September 2017 to March 2020 were retrospectively enrolled. EMRO was performed by a single experienced endoscopist. Patients' characteristics and treatment outcomes were assessed. Results  The En bloc and R0 resection rates were 100 % (14/14) and 92.9 % (13/14), respectively. The median pathological resected specimen size was 10 mm, with a median pathological resected tumor size of 6 mm. During the EMRO procedure, there was no occurrence of misplacement of the OTSC to the target lesion. With respect to the pathological resection depth, nine cases (64.3 %) and five cases (35.7 %) were categorized as deep submucosal resection and muscularis resection, respectively, whereas no case was categorized as full-thickness resection. There were no intraoperative or delayed perforations. However, delayed bleeding occurred in two cases. At a median follow-up of 12 months (range 7-36) after EMRO, there was no incidence of local recurrence. At the first follow-up endoscopy performed at 6 months after EMRO, the OTSC was retained in place in two of 14 DNETs (14.3 %). Conclusions  EMRO can be performed safely, by an experienced endoscopist, for small (≤ 10 mm) DNETs.Background and study aims  The pocket-creation method (PCM) facilitates dissection of the central part of a tumor. We previously developed the PCM with clip traction (PCM-CT) to facilitate opening the mucosal pocket, which otherwise could become cumbersome. In the present study, we aimed to examine the feasibility of PCM-CT for colorectal endoscopic submucosal dissection (ESD). Patients and methods  PCM-CT was performed on 30 patients with early colorectal tumors from October 2019 to April 2020. PCM-CT allows efficient opening of the mucosal pocket by using the PCM to dissect the center of the lesion and then apply traction with a single clip after making a circumferential mucosal incision. Results  The median specimen major axis length, ESD time, ESD speed, and en bloc resection rate were 48 mm, 84 minutes, 20 mm 2 /min, and 100 % (30/30), respectively. The success rates for the traction clip and median single-clip-traction time were 100 % (30/30) and 1.5 minutes, respectively. selleck products Conclusions  Colorectal ESD using PCM-CT is a simple and promising method.The pandemics of major infectious diseases often cause public health, economic, and social problems. Virtual reality (VR) and augmented reality (AR), as two novel technologies, have been used in many fields for emergency management of disasters. The objective of this paper was to review VR and AR applications in the emergency management of infectious outbreaks with an emphasis on the COVID-19 outbreak. A search was conducted in MEDLINE (PubMed), Embase, IEEE, Cochrane Library, Google Scholar, and related websites for papers published up to May 2, 2020. The VR technology has been used for preventing or responding to infections by simulating human behaviors, infection transmission, and pathogen structure as a means for improving skills management and safety protection. Telehealth, telecommunication, and drug discovery have been among the other applications of VR during this pandemic. Moreover, AR has also been used in various industries, including healthcare, marketing, universities, and schools. Providing high-resolution audio and video communication, facilitating remote collaboration, and allowing the visualization of invisible concepts are some of the advantages of using this technology. However, VR has been used more frequently than AR in the emergency management of previous infectious diseases with a greater focus on education and training. The potential applications of these technologies for COVID-19 can be categorized into four groups, i.e., 1) entertainment, 2) clinical context, 3) business and industry, and 4) education and training. The results of this study indicate that VR and AR have the potential to be used for emergency management of infectious diseases. Further research into employing these technologies will have a substantial impact on mitigating the destructive effects of infectious diseases. Making use of all the potential applications of these technologies should be considered for the emergency management of the current pandemic and mitigating its negative impacts.

Autoři článku: Holmeskock0625 (Henriksen Noble)