Verze z 29. 9. 2024, 15:28, kterou vytvořil Vintermidtgaard9722 (diskuse | příspěvky) (Založena nová stránka s textem „MSD+VB showed high clinical concordance (TaC = 89% and CsA = 98%). Inter- and intra-precision was ≤11.5 %CV for TaC and CsA. Samples were stable for up t…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

MSD+VB showed high clinical concordance (TaC = 89% and CsA = 98%). Inter- and intra-precision was ≤11.5 %CV for TaC and CsA. Samples were stable for up to 7 days at room temperature with an average difference of less then 10%. Clinical validation with MSD+CB correlated well with VB for CsA (slope = 0.95, r2 = 0.88, n = 47) and TaC (slope = 0.98, r2 = 0.82, n = 49). CB vs. VB gave concordance of 94% for CsA and 79% for TaC. A satisfaction survey showed 82% of patients preferred having the capillary collection option. Conclusion Transplant patients favored having the ability to collect capillary samples at home for TaC/CsA monitoring. Our results demonstrate good concordance between MSD+CB and VB for TaC and CsA TDM, but additional studies are warranted.Background Deafness and hearing loss are common conditions that can be seen independently or as part of a syndrome and are often mediated by genetic causes. We sought to develop and validate a hereditary hearing loss panel (HHLP) to detect single nucleotide variants (SNVs), insertions and deletions (indels), and copy number variants (CNVs) in 166 genes related to nonsyndromic and syndromic hearing loss. Methods We developed a custom-capture next-generation sequencing (NGS) reagent to detect all coding regions, ±10 flanking bp, for the 166 genes related to nonsyndromic and syndromic hearing loss. Our validation consisted of testing 52 samples to establish accuracy, reproducibility, and analytical sensitivity. In addition to NGS, supplementary methods, including multiplex ligation-dependent probe amplification, long-range PCR, and Sanger sequencing, were used to ensure coverage of regions that had high complexity or homology. selleck chemicals Results We observed 100% positive and negative percentage agreement for detection of SNVs (n = 362), small indels (1-22 bp, n = 25), and CNVs (gains, n = 8; losses, n = 17). Finally, we showed that this assay was able to detect variants with a variant allele frequency ≥20% for SNVs and indels and ≥30% to 35% for CNVs. Conclusions We validated an HHLP that detects SNVs, indels, and CNVs in 166 genes related to syndromic and nonsyndromic hearing loss. The results of this assay can be utilized to confirm a diagnosis of hearing loss and related syndromic disorders associated with known causal genes.Background Macroprolactin is an immunoglobulin-prolactin complex that is not bioactive in vivo but the prolactin component remains immunoreactive. The complex is a universal source of interference in prolactin immunoassays and commonly results in misdiagnosis of hyperprolactinemia with consequent clinical mismanagement of patients. Removal of macroprolactin by precipitation with polyethylene glycol (PEG) is an effective technique for identifying such patients but unfortunately not universally employed due to the manual nature of the procedure. Methods We developed a modified PEG precipitation technique using magnetic nanoparticles that we termed Magnetically Assisted PEG Precipitation (MAPP). This procedure was verified against an established PEG precipitation procedure. Results The MAPP procedure we developed was robust, reproducible, and affords the potential for automation of macroprolactin screening in clinical laboratories. Comparisons of prolactin levels obtained following MAPP in sera from patients with either true hyperprolactinemia or macroprolactinemia generated results comparable to that of conventional PEG precipitation. Conclusions The MAPP technique yields results comparable to those of traditional PEG precipitation. Elimination of the need for centrifugation affords the possibility of automation and hence more widespread adoption of routine PEG screening by clinical laboratories.Background The psychoactive component of cannabis, tetrahydrocannabinol (THC), is one of many cannabinoids present in the plant. Since cannabinoids have extensive structural similarity, it is important to be aware of potential cross-reactivity with immunoassays designed to detect THC metabolite. This is especially important as cannabinoid products are increasingly marketed as legal supplements. The objective of this study was to assess the cross-reactivity of 2 commercial immunoassays designed to detect THC metabolite with 4 cannabinoids cannabidiol, cannabinol, cannabichromene, and cannabigerol. Methods Deidentified residual patient urine samples that tested negative for THC metabolite on initial testing were pooled and fortified with the above compounds to detect cross-reactivity. We next tested a range of CBN concentrations to determine what concentration of CBN was required to trigger a positive immunoassay result. Finally, we tested whether CBN has an additive effect with THC in the immunoassay by adding CBN to 21 samples weakly positive for THC by a mass spectrometry method but negative by the EMIT II Plus immunoassay. Results Both the EMIT II Plus assay and the Microgenics MultiGent assay demonstrated cross-reactivity with CBN. For the EMIT II Plus assay, about 5-fold more CBN than THC metabolite was required to produce an assay signal equivalent to the cutoff concentration, and CBN displayed an additive effect with THC metabolite. For the Microgenics assay, 20-fold more CBN than THC metabolite was required to cross the cutoff concentration. Conclusions These data may help guide the need for confirmatory testing when results of THC metabolite testing by immunoassay are inconsistent with expectations.Background Cholesterol efflux capacity is a tissue culture assay for HDL function that is not amenable for high-throughput monitoring of risk assessment. Methods We devised a cell-free HDL function assay to measure the exchange rate of exogenous apoA1 into serum HDL using NBD/Alexa647 double-labeled apoA1, whose NBD/Alexa647 emission ratio increased upon exchange into HDL. ApoA1 exchange rate (AER) was assayed by incubating labeled apoA1 with human serum, and the rate of the increase of the NBD/Alexa647 ratio over time was calculated as AER. Results Fast protein liquid chromatography analysis of serum confirmed that the labeled apoA1 selectively exchanged into the HDL lipoprotein fraction. Characterization studies demonstrated that the AER assay had excellent intra- and inter-day reproducibility, was stable over 3 freeze-thaw cycles, and yielded similar results with serum or plasma. We quantified AER in serum from randomly selected stable subjects undergoing elective diagnostic coronary angiography (n = 997).

Autoři článku: Vintermidtgaard9722 (Nance McCracken)