Hamannguldborg3012
32, paCO2 82 mm Hg, paO2 50 mm Hg, HCO3 41.7 mmol/L, FiO2 32% to pH 7.21, paCO2 91.7 mm Hg, paO2 59 mm Hg, HCO3 36.6 mmol/L, and FiO2 32%. Case 2 was a 62-year-old male with COPD who was dependent on supplemental oxygen and presented to the ED with acute on chronic hypercapnic respiratory failure. He was given acetazolamide in the ED with similar results ABG on presentation pH 7.37, paCO2 79.3 mm Hg, paO2 77.6 mm Hg, HCO3 45.5 mmol/L, and FiO2 32%. The next morning, ABG was pH 7.29, paCO2 79 mm Hg, paO2 77 mm Hg, HCO3 45.5 mmol/L, and FiO2 32%. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS? Acetazolamide given early in the uncompensated setting can worsen acidosis and potentiate clinical deterioration. BACKGROUND Pseudoaneurysms of the foot are rare and can occur from a range of etiologies, including laceration from a foreign body. The majority of reported cases have been diagnosed by computed tomography, magnetic resonance imaging, or angiography. These tests require intravenous access and contrast, confer radiation, take time to perform and interpret, are expensive, and are not always readily available in the acute setting. No prior reported pseudoaneurysms of the foot have been diagnosed by point-of-care ultrasound (POCUS). CASE REPORT An 8-year-old boy presented to the emergency department for evaluation of left foot pain and swelling 2 weeks after stepping on small pieces of broken glass. He had a 3 × 3 cm area of painful swelling and erythema at the medial plantar aspect of his foot. A cutaneous abscess was the working diagnosis and preparations were made for an incision and drainage procedure. However, POCUS revealed a medial plantar artery pseudoaneurysm. Incision and drainage would have led to unexpected arterial bleeding. Instead, the pediatric surgery service was consulted for pseudoaneurysm excision and arterial ligation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS? Incision of a pseudoaneurysm in the sole of the foot-thought to be an abscess based on clinical examination-would lead to unforeseen arterial bleeding. POCUS at the bedside can differentiate between simple abscess and pseudoaneurysm in order to guide appropriate and time-sensitive management. Historical and clinical clues to the diagnosis may include heavier-than-expected bleeding at the time of laceration and a pulsatile quality to the painful erythema and swelling. PURPOSE To evaluate the clinical outcomes of patients who underwent biologically enhanced patch augmentation repair for the treatment of revision massive rotator cuff tears. METHODS Twenty-two patients who underwent arthroscopic and mini-open rotator cuff repair using a patch augmented with platelet-rich plasma and concentrated bone marrow aspirate (cBMA) for revision massive (≥2 tendons) rotator cuff tears from 2009 to 2014, with a minimum 1-year follow-up, were included in the study. In this procedure the medial side of the graft is secured to the rotator cuff tendon remaining medially. American Shoulder and Elbow Surgeons (ASES), Simple Shoulder Test, and postoperative Single Assessment Numerical Evaluation scores were evaluated. To determine the clinical relevance of ASES scores, the minimal clinically important difference, substantial clinical benefit (SCB), and the patient-acceptable symptomatic state (PASS) thresholds were used. Clinical success or failure was defined based on whether the patient reachentation repair reached substantial clinical benefit, whereas 32% reached or exceeded the PASS criteria. LEVEL OF EVIDENCE Case Series Level IV. Electronic nicotine delivery systems and vaping devices are now the most commonly used forms of tobacco consumed by youth and young adults. A variety of chemicals and toxicants released during inhalation have harmful systemic effects and effects on the lung. The known and potential health consequences are particularly alarming. SB-297006 chemical structure There is concern that use of these devices will create a new generation of life-long smokers with nicotine and polysubstance addiction. Beyond the concerning chronic health effects of regular use, there is a recent epidemic of severe, acute lung disease termed e-cigarette, or vaping product use-associated lung injury, (EVALI), associated with high morbidity and mortality. These issues demand immediate public health attention. Healthcare providers play key roles in limiting the exposure of youth and young adults to these products by providing evidence-based counseling to patients and families, and by advocating for regulations to protect against childhood initiation and continuation of use. PURPOSE To compare fetal ultrasound measurements performed by two observers with different levels of experience and evaluate the potential contribution of the use of three-dimensional (3D) ultrasound on repeatability, reproducibility and agreement of two-dimensional (2D) and 3D-derived measurements. MATERIALS AND METHODS Two observers (one senior and one junior) measured head circumference (HC), abdominal circumference (AC) and femur length (FL) in 33 fetuses (20 to 40 weeks of gestation). Each observer performed two series of 2D measurements and two series of 3D measurements (i.e., measurements derived from triplane volume processing). Measurements were converted into Z-scores according to gestational age. Variability between the different series of measurements was studied using Bland-Altmann plots and intra-class correlation coefficients (ICC). RESULTS Agreement with the 2D measurements of the senior observer was higher in 3D than in 2D for the junior observer (systematic differences of -0.4, -0.2 and -0.8 Z-score vs. -0.1, -0.1 and -0.6 for HC, AC and FL on 2D and 3D datasets, respectively). The use of 3D ultrasound improved junior observer repeatability (ICC=0.94, 0.88, 0.90 vs. 0.94, 0.94 and 0.96 for HC, AC and FL in 2D and 3D, respectively). The reproducibility was greater using the junior observer 3D datasets (ICC=0.75, 0.60 and 0.45 vs. 0.79, 0.89 and 0.63 for HC, AC and FL, respectively). CONCLUSION The use of 3D ultrasound improves the consistency of the measurements performed by a junior observer and increases the overall repeatability and reproducibility of measurements performed by observers with different levels of experience.