Kuhnballard3039
01). At the end of treatment, recurrence was found in 7 cases (10.14%) in CHM and 11 cases (26.19%) in placebo (χ2 = 4.947, P < 0.05). In the main outcome measures, 56 patients (56%) in the CHM group and 25 patients (25%) in the placebo group were satisfied with their bowel movements (χ2 = 19.940, P < 0.05). Increased complete spontaneous bowel movements ≥3 per week from baseline were found in 40 patients (40%) who received CHM and 19 patients (19%) who received placebo (χ2 = 10.602, P < 0.05). No serious adverse effects were found in any of the recruited cases.
CHM XiaojiDaozhi Decoction is a safe and effective method for the treatment of childhood constipation.
CHM XiaojiDaozhi Decoction is a safe and effective method for the treatment of childhood constipation.Surgical resection of the lower jaw due to the presence of a benign or malignant tumor is the most frequent cause of mandibular deviation. Location and extent of the tumor decide the surgical modality of mandibulectomy to be performed. The clinician must wait for an adequate span of time for completion of the healing and acceptance of the osseous graft before considering a definitive prosthesis. During the inceptive healing period, prosthodontic intervention is of utmost priority for preventing the mandibular deviation. A corrective appliance termed "guide flange prosthesis (GFP)" is indicated to limit this clinical manifestation. The basic intention of rehabilitation is to train the mandibular muscles and to re-establish an acceptable occlusal relationship so that the patient can adequately control the opening and closing movements. This case series describes early prosthodontic management of three patients who had undergone hemimandibulectomy, with different techniques of fabrication of a GFP. The three techniques described consist of two conventional methods of fabrication while the third technique is a new innovative approach.Kenny-Caffey syndrome (KCS) is a rarely reported autosomal disorder characterized by skeletal, ocular, and oral manifestations. Oral features such as microdontia, hypodontia, malalignment of teeth, bone loss, and difficulty in mastication results in serious esthetic and functional handicap. The prosthetic rehabilitation of such patients is challenging, especially when implant placement is not a good choice due to poor Vitamin D levels. The existing literature is scarce in describing the treatment options. This case report describes the oral rehabilitation of a patient affected with KCS using telescopic overdenture.
To investigate the effect of different cooling methods on denture base adaptation of rapid heat-cured acrylic resin using 3D superimposition technique.
In vitro - Comparative study.
Denture base adaptation of two different rapid heat-cured polymethyl methacrylate acrylic resins using five different cooling methods were compared. Forty maxillary edentulous stone cast were prepared to produce the denture bases with standardized thickness. The specimens were divided into five groups (n = 8) according to type of materials and cooling methods. The master stone cast and all forty denture bases were scanned with 3Shape E1 laboratory scanner. The scanned images of each of the denture bases were superimposed over the scanned image of the master cast using Materialize 3-matic software. Three dimensional differences between the two surfaces were calculated and color surface maps were generated for visual qualitative assessment.
Generalized Linear Model Test, Bonferroni Post Hoc Analysis.
All bench-cooled specimens showed wide green-colored area in the overall palatal surface, while the rapid cooled specimens presented with increased red color areas especially at the palate and post dam area. Generalized Linear Model test followed by Bonferroni post hoc analysis showed significant difference in the root mean square values among the specimen groups.
Samples that were bench cooled, demonstrated better overall accuracy compared to the rapid cooling groups. Regardless of need for shorter denture processing time, bench cooling of rapid heat-cured PMMA is essential for acceptable denture base adaptation.
Samples that were bench cooled, demonstrated better overall accuracy compared to the rapid cooling groups. Regardless of need for shorter denture processing time, bench cooling of rapid heat-cured PMMA is essential for acceptable denture base adaptation.
This study aimed to evaluate the marginal and internal discrepancy of the zirconia coping fabricated by two dental computer-aided design-computer-aided manufacturing (CAD-CAM) systems.
In vitro comparative study.
Twenty zirconia crowns fabricated from inCoris ZI by Cerec InLab CAD-CAM system (Dentsply Sirona Inc, USA) and Ceramill ZI by Ceramill CAD-CAM system (Amann Girrbach, Austria) were measured the discrepancy at six locations using silicone replica technique. Absolute marginal discrepancy (AMD) and marginal gap (MG) represent the marginal discrepancy, and the other four locations at chamfer area, axial wall, cusp tip, and occlusal adaptation represent the internal discrepancy. The gap was measured using an optical light microscope at ×50 magnification.
The data were analyzed using two-way ANOVA and Game-Howell post hoc test.
The statistical analysis showed that the accuracy of zirconia coping depends on CAD-CAM system and the location of measurement. Cerec InLab showed the marginal discrepancy of the coping 119.5 ± 44.8 μm at MG position and 125.3 ± 36.6 μm at AMD position, which was statistically larger than Ceramill system did at 53.0 ± 12.1 μm and 67.2 ± 19.1 μm. On the other hand, the discrepancy in other positions showed no statistical difference between the two CAD-CAM systems.
The accuracy of zirconia coping was significant affected by CAD-CAM system and the location of measurement.
The accuracy of zirconia coping was significant affected by CAD-CAM system and the location of measurement.
The aim is to study the effect of freshly placed composite build-ups on setting of additional silicone impression materials.
In vitro - experimental study.
Three composite materials; Build-It™ F. R™, Filtek™ Bulk Fill flow and Filtek™ Z350 and three light-bodied additional silicone impression materials; Elite HD+, Aquasil LV Ultra and Express™ were used. Cylindrical-shaped specimens were made of each material (diameter 15 mm and height 10 mm). The silicone specimens were brought into contact with the composite specimens, which were either freshly cured (9 groups, n = 90) or cured and then stored in normal saline for 1 week (9 groups, n = 90). Shore A hardness (SAH) scores of silicone surfaces were recorded following the ASTM D2240-5 standards for shore A Durometer testing. Vismodegib order Six measurements were made per each silicone surface and medians were calculated. Kruskal-Wallis and Mann-Whitney tests (SPSS v20) were used to check statistical significant differences between all groups and paired comparisons, respectively (P < 0.