Bucknerzimmerman6226

Z Iurium Wiki

Verze z 19. 9. 2024, 21:32, kterou vytvořil Bucknerzimmerman6226 (diskuse | příspěvky) (Založena nová stránka s textem „rategy showed excellent performance in all workflow tests in preparation of the clinical introduction on the Unity MR-linac.Objective. This study aimed to…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

rategy showed excellent performance in all workflow tests in preparation of the clinical introduction on the Unity MR-linac.Objective. This study aimed to explore an online, real-time, and precise method to assess steady-state visual evoked potential (SSVEP)-based visual acuity more rapidly and objectively with self-adaptive spatial frequency steps.Approach. Taking the vertical sinusoidal reversal gratings with different spatial frequencies and temporal frequencies as the visual stimuli, according to the psychometric function for visual acuity assessment, a self-adaptive procedure, the best parameter estimation by sequential testing algorithm, was used to calculate the spatial frequency sequence based on all the previous spatial frequencies and their significance of the SSVEP response. Simultaneously, the canonical correlation analysis (CCA) method with a signal-to-noise ratio (SNR) significance detection criterion was used to judge the significance of the SSVEP response.Main results.After 18 iterative trails, the spatial frequency to be presented converged to a value, which was exactly defined as the SSVEP visual acuity threshold. Our results indicated that this SSVEP acuity had a good agreement and correlation with subjective Freiburg Visual Acuity and Contrast Test acuity, and the test-retest repeatability was also good.Significance. The self-adaptive step SSVEP procedure combined with the CCA method and SNR significance detection criterion appears to be an alternative method in the real-time SSVEP acuity test to obtain objective visual acuity more rapidly and precisely.In the context of reducing the patient dose coming from CT scanner examinations without penalizing the diagnosis, the assessment of both patient dose and image quality (IQ) with relevant metrics is crucial. The present study represents the first stage in a larger work, aiming to compare and optimize CT protocols using dose and IQ new metrics. We proposed here to evaluate the capacity of the Non-PreWhitening matched filter with an eye (NPWE) model observer to be a robust and accurate estimation of IQ. We focused our work on two types of clinical tasks a low contrast detection task and a discrimination task. We designed a torso-shaped phantom, including Plastic Water®slabs with cylindrical inserts of different diameters, sections and compositions. We led a human observer study with 13 human observers on images acquired in multiple irradiation and reconstruction scanning conditions (voltage, pitch, slice thickness, noise level of the reconstruction algorithm, energy level in dual-energy mode and dose), to evaluate the behavior of the model observer compared to the human responses faced to changing conditions. The model observer presented the same trends as the human observers with generally better results. We rescaled the NPWE model on the human responses by scanning conditions (kVp, pitch, slice thickness) to obtain the best agreement between both observer types, estimated using the Bland-Altman method. The impact of some scanning parameters was estimated using the correct answer rate given by the rescaled NPWE model, for both tasks and each insert size. In particular, the comparison between the dual-energy mode at 74 keV and the single-energy mode at 120 kVp showed that, if the 120 kVp voltage provided better results for the smallest insert at the lower doses for both tasks, their responses were equivalent in many cases.ITO/NiO/ZnO npn heterojunction bipolar phototransistors (HBPTs) with various base widths are fabricated using a radio-frequency sputtering system. read more The effects of base-width modulation on the optoelectronic characteristics of the prepared HBPTs are studied. The dark current of HBPTs decreases with increasing base width because the injected electrons from the emitter are recombined in the wide base region. The photocurrent increases with decreasing base width, which is attributed to higher emitter-base injection efficiency. The responsivity increases with the collector-emitter voltage (VCE) in the HBPTs with a 100 nm base width, whereas the responsivity sharply decreases at VCE > 4 V for the HBPTs with a thinner base width (80 nm) due to the punch-through effect. In contrast, the responsivity approaches saturation at large VCE for HBPTs with a thicker base width (120 nm). The responsivity and detectivity decrease with increasing incident light intensity, which is caused by an increase in the base recombination loss. The HBPTs with a base width of 100 nm exhibits the largest responsivity and detectivity; their detectivity is higher than that of HBPTs with base widths of 80 and 120 nm by approximately two and three orders, respectively.Aggregation of molecules is a multi-molecular phenomenon occurring when two or more molecules behave differently from discrete molecules due to their intermolecular interactions. Moving beyond single molecules, aggregation usually demonstrates evolutive or wholly emerging new functionalities relative to the molecular components. Conjugated small molecules and polymers interact with each other, resulting in complex solution-state aggregates and solid-state microstructures. Optoelectronic properties of conjugated small molecules and polymers are sensitively determined by their aggregation states across a broad range of spatial scales. This review focused on the aggregation ranging from molecular structure, intermolecular interactions, solution-state assemblies, and solid-state microstructures of conjugated small molecules and polymers. We addressed the importance of such aggregation in filling the gaps from the molecular level to device functions and highlighted the multi-scale structures and properties at different scales. From the view of multi-level aggregation behaviors, we divided the whole process from the molecule to devices into several parts molecular design, solvation, solution-state aggregation, crystal engineering, and solid-state microstructures. link2 We summarized the progress and challenges of relationships between optoelectronic properties and multi-level aggregation. We believe aggregation science will become an interdisciplinary research field and serves as a general platform to develop future materials with the desired functions.Electrocatalytic performance of low-cost graphitic carbon nitride (CN) is greatly limited by its limited conductivity and small specific surface area. Herein, a simple and cost-effective idea to produce novel nanocomposite is constructed by the CN and cetyl trimethyl ammonium bromide functionalized carbon black (CB) anchored platinum nanoparticles as highly efficient oxygen reduction catalysts based on gamma irradiation. The assembled carbon nitride/positive carbon black anchoring PtNPs (Pt/CN2-CB+1) catalyst exhibits significantly improved specific surface area, high graphitization, and uniformly dispersed ultra-small platinum nanoparticles. link3 For the oxygen reduction reaction (ORR) performance, the catalyst shows more positive onset-potential (0.93 V versus RHE) and larger diffusion limiting current density (5.65 mA cm-2) compared with benchmark Pt/C catalysts in alkaline medium. Moreover, the Pt/CN2-CB+1catalyst exhibits a small Tafel slope (92 mV dec-1). Besides, the catalyst was demonstrated the remarkable methanol tolerance and good long-term stability under working conditions. This work provides a new and effectiveγ-rays irradiation for synthesizing the carbon nitride catalysts for energy conversion and storage applications.Objective.In the last decade, the advent of code-modulated brain-computer interfaces (BCIs) has allowed the implementation of systems with high information transfer rates (ITRs) and increased the possible practicality of such interfaces. In this paper, we evaluate the effect of different numbers of targets in the stimulus display, modulation sequences generators, and signal processing algorithms on the accuracy and ITR of code-modulated BCIs.Approach.We use both real and simulated electroencephalographic (EEG) data, to evaluate these parameters and methods. Then, we compared numerous different setups to assess their performance and identify the best configurations. We also evaluated the dependability of our simulated evaluation approach.Main results.Our results show that Golay, almost perfect, and deBruijn sequence-based visual stimulus modulations provide the best results, significantly outperforming the commonly used m-sequences in all cases. We conclude that artificial neural network processing algorithms offer the best processing pipeline for this type of BCI, achieving a maximum classification accuracy of 94.7% on real EEG data while obtaining a maximum ITR of 127.2 bits min-1in a simulated 64-target system.Significance.We used a simulated framework that demonstrated previously unattainable flexibility and convenience while staying reasonably realistic. Furthermore, our findings suggest several new considerations which can be used to guide further code-based BCI development.

To evaluate the metabolic relevance of type of locomotion in anaerobic testing by analyzing and comparing the metabolic profile of the Bosco Continuous Jumping Test (CJ30) with the corresponding profile of the Wingate Anaerobic Test (WAnT).

A total of 11 well-trained, male team-sport athletes (age = 23.7 [2.2]y, height = 184.1 [2.8]cm, weight = 82.4 [6.4]kg) completed a CJ30 and WAnT each. During the WAnT, power data and revolutions per minute were recorded, and during the CJ30, jump height and jumping frequency were recorded. In addition, oxygen uptake and blood lactate concentration were assessed, and metabolic profiles were determined via the PCr-LA-O2 method.

In the CJ30, metabolic energy was lower (109.3 [18.0] vs 143.0 [13.1]kJ, P < .001, d = -2.302), while peak power (24.8 [4.4] vs 11.8 [0.5]W·kg-1, P < .001, d = 3.59) and mean power (20.8 [3.6] vs 9.1 [0.5]W·kg-1, P < .001, d = 4.14) were higher than in the WAnT. The metabolic profiles of the CJ30 (aerobic energy = 20.00% [4.7%], anaerorobic share in both tests is similar and predominant, the CJ30 primarily taxes the WPCr system, while the WAnT more strongly relies on the glycolytic pathway. Thus, the 2 tests should not be used interchangeably, and the type of locomotion seems crucial when choosing an anaerobic test for a specific sport.

Increasing age, high quadriceps strength, and low hamstring muscle strength are associated with hamstring strain injury in soccer. The authors investigated the age-related variation in maximal hamstring and quadriceps strength in male elite soccer players from under-13 (U-13) to the senior level.

A total of 125 elite soccer players were included from a Danish professional soccer club and associated youth academy (first tier; U-13, n = 19; U-14, n = 16; U-15, n = 19; U-17, n = 24; U-19, n = 17; and senior, n = 30). Maximal voluntary isometric force was assessed for the hamstrings at 15° knee joint angle and for the quadriceps at 60° knee joint angle (0° = full extension) using an external-fixated handheld dynamometer. Hamstring-to-quadriceps strength (HQ) ratio and hamstring and quadriceps maximal voluntary isometric force levels were compared across age groups (U-13 to senior).

Senior players showed 18% to 26% lower HQ ratio compared with all younger age groups (P ≤ .026). Specific HQ ratios (mean [95% confidence interval]) were as follows senior, 0.

Autoři článku: Bucknerzimmerman6226 (Abel Daniel)