Wentworthshoemaker4224
Although no Type I, II, or III SNEs were identified in any specimen, type IVa mechanoreceptor (FNEs) was immunohistochemically characterized in 13 (34%) pulvinar, 19 (50%) LT, and 16 (42%) HJC specimens. The total density of FNEs was 3.31±5.70)/50 mm2 (range 0-21) in pulvinar specimens, 3.18 ± 5.92)/50 mm2 (range 0-24) in HJC specimens, and 4.51±6.61/50 mm2 (range 0-22) in LT specimens. Furthermore, the operated side, gender, and the number of FNEs in specimens did not differ significantly among the age groups (p>0.05 for all), and the number of FNEs was not significantly correlated with age, gender, or the operated side (p>0.05 for all).
Evidence from this study revealed that pulvinar, LT, and HJC include only FNEs, which play a role in pain sensation, among mechanoreceptors. Surgical excision of these tissues may not cause a significant loss of sensory function in the hip joint of children with DDH.
Level II, Therapeutic Study.
Level II, Therapeutic Study.
This study aimed to compare the clinical and radiological findings of radical reduction (open reduction and Salter innominate osteotomy combined with femoral osteotomy) for children of walking age, younger and older than 4 years in the treatment of with developmental dysplasia of the hip (DDH).
In this retrospective study, children of walking age with DDH who underwent radical reduction between 2008 and 2014 were identified. They were then divided into 2 groups according to the age at which the surgery was performed before and after the age of 4 years. Improvement in the acetabular index was examined on follow-up radiographs. The presence of avascular necrosis (AVN) was determined and classified on the basis of the Kalamchi-MacEwen classification on final follow-up radiographs. Clinical assessment was performed with the modified McKay criteria at the final follow-up appointment.
A total of 19 children (14 girls, 5 boys; mean age=37.5±21 months) (25 hips) were included. Their mean age was 27.9±4.9 and 63rapeutic Study.
This study aimed to compare the clinical and radiological results of percutaneous mesh-container-plasty (PMCP) versus percutaneous kyphoplasty (PKP) in the treatment of osteoporotic thoracolumbar burst fractures.
A prospective study of 122 patients with osteoporotic thoracolumbar burst fractures was conducted. The patients were nonrandomly assigned to receive PKP (62; 16 men, 46 women) and PMCP (60; 14 men, 46 women). The epidemiological data, surgical outcomes, and clinical and radiological features were compared between the 2 groups. Cement leakage, height restoration, deformity correction, canal compromise, and cement distribution were calculated from the radiographs. Visual pain analog scale (VAS), the Oswestry disability index (ODI), and short-form 36 health survey domains role physical (SF-36 rp) and bodily pain (SF-36 bp) were calculated before surgery and immediately and 2 years after surgery.
Although VAS, ODI, SF-36 bp, and SF-36 rp scores improved from 7 (6-9), 71.28±16.38, 22 (0-32), and 25 n the PMCP group (2/60) than in the PKP group (10 vs. 62, p<0.05).
Both PKP and PMCP treatments seem to have significant ability in pain relief and functional recovery. Despite its higher cost, PMCP treatment may have a better inhibition ability of cement leakage, cement distribution, height restoration, and improvement in segmental kyphosis than PKP treatment for osteoporotic thoracolumbar burst fractures.
Level II, Therapeutic Study.
Level II, Therapeutic Study.
This study aimed to evaluate the possible effects of surgical procedures on mortality and to identify the possible risk factors for mortality in the management of geriatric hip fractures.
A total of 191 patients (105 women and 86 men; mean age 82.26±9.681 [60-108] years) with AO/OTA 31A2.2 intertrochanteric fractures and treated with sliding hip screw, proximal femoral nail, or hemiarthroplasty were included in this retrospective cohort study. The treatment type was decided by the responsible surgeon according to the patients' pre-injury activity level, bone quality, and features of the fracture. Age, sex, type of fracture, type of surgery performed, American society of anesthesiology (ASA) grade, type of anesthesia, time to surgery, type of physical therapy, length of hospital stay, and number of comorbidities were documented. We evaluated the 30-day and 1-year mortality of patients treated with sliding hip screw (SHS), proximal femoral nail antirotation (PFN-A), or hemiarthroplasty and identified the posty procedures are associated with higher mortality rates in elderly patients with hip fractures. Thus, we highly recommend orthopedic surgeons to consider all these factors in the management of intertrochanteric hip fractures in the geriatric population.
Level IV, Prognostic Study.
Level IV, Prognostic Study.
The aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two different working lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.
From the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated; the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groups A and B). Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA. Two loading conditions (axial compression and torsion) were applied at the center of the femoral head. Construct stiffness, interfragmentary micromotion, and the peak von Mises stress (VMS) on the plate were assessed.
Group D provided the highest axial stiffness (1347 N/mm), and group A was the weakest (439 N/mm). Poziotinib cell line With the lag screw, shear micromotion remained generally low compared with (102 mm working length, 700 N). The percentage decreases of the peak VMS under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >40% and 69%, respectively, while those for the 82-mm working length were >47% and 61%, respectively.
The current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct provides better torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally, the strength of the materials is increased and implant failure can be minimized by using this technique.
The current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct provides better torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally, the strength of the materials is increased and implant failure can be minimized by using this technique.
This study aimed to determine the characteristics of instant messaging application (IMA) usage for clinical consultation among orthopedic residents in Turkey and to explore their experiences and opinions concerning potential legal problems.
A questionnaire titled "Instant messaging for consultation among orthopedic surgeons" consisting of 21 questions was applied to orthopedic surgery residents, and the results were analyzed. The questions were designed to obtain information on 4 categories 1) demographics and professional experience, 2) attitudes on the use of cellular phones, 3) IMA usage for clinical consultation purposes, and 4) problems and comments on smartphone application usage for clinical consultation purposes. The participants who had no experience with a smartphone or IMA usage were excluded at the final analysis.
A total of 860 orthopedic residents (849 males [98.7%]; mean age=28.6 years; age range=22-44 years) participated in the survey (participation rate 97.3%). The distribution of resid to develop applications only for medical consultation purposes. Most of the trainees make decisions using IMAs without a proper examination, putting the patients at the risk of misdiagnosis. Moreover, the confidentiality of the patient's personal information appears to be in danger when IMAs are used.
Level IV, Diagnostic Study.
Level IV, Diagnostic Study.Medical interventions are becoming more complex day by day. Moreover, compared with the past, more healthcare professionals take part in the same intervention in the field of medicine. The use of technology in medical interventions has also increased. This change in the health sector brings together several legal discussions. In this study, the legal consequences that arise from the treatment processes carried out by the residents and resident educators (registerers / attending physicians), the exchange of information between them, and the usage of some messaging platforms, especially WhatsApp, in this process will be analyzed.
Endovascular therapy has recently become acceptable for the reconstruction of below-the-knee (BTK) and below-the-ankle (BTA) arterial lesions. However, we have sometimes experienced BTK or BTA lesions with calcifications that are too severe for balloon catheters to cross or expand despite successful guidewire passage. In this study, we assessed the feasibility and safety of the novel inner PIERCE technique for breaking down the calcium burden of BTK and BTA arterial lesions.
We retrospectively reviewed the records of patients who had undergone endovascular therapy between August 2018 and December 2019. The inner PIERCE technique was performed in those cases where low-profile balloon catheters were unable to pass through the target lesions or balloon indentation did not disappear beyond the rated burst pressure. An externalized guidewire system was established in 8 cases via bidirectional approaches, and a 20-gauge needle was directly inserted through the guidewires from the distal puncture site. In 10 cases of successful antegrade wiring, the tibial or pedal arteries distal to the lesion site were punctured for a retrograde guidewire approach to the lesion. The needle was slowly rotated and advanced across the lesion.
We found that all lesions were severely calcified and 83.3% had chronic total occlusion. The inner PIERCE procedure allowed successful passage of the needle and subsequent low-profile balloon catheters in all cases. Optimal balloon dilatation was achieved in 94.4% of the cases using this technique. No procedure-related adverse events were observed.
The novel inner PIERCE technique is a safe and feasible method for disrupting calcified BTK and BTA lesions.
The novel inner PIERCE technique is a safe and feasible method for disrupting calcified BTK and BTA lesions.During the coronavirus disease 2019 (COVID-19) pandemic period, container computed tomography (CT) scanners were developed and used for the first time in China to perform CT examinations for patients with clinically mild to moderate COVID-19 who did not need to be hospitalized for comprehensive treatment, but needed to be isolated in Fangcang shelter hospitals (also known as makeshift hospitals) to receive some supportive treatment. The container CT is a multidetector CT scanner installed within a radiation-protected stand-alone container (a detachable lead shielding room) that is deployed outside the makeshift hospital buildings. The container CT approach provided various medical institutions with the solution not only for rapid CT installation and high adaptability to site environments, but also for significantly minimizing the risk of cross-infection between radiological personnel and patients during CT examination in the pandemic. In this article, we described the typical setup of a container CT and how it worked for chest CT examinations in Wuhan city, the epicenter of COVID-19 outbreak.