Blackburnpugh8780

Z Iurium Wiki

Verze z 16. 9. 2024, 23:30, kterou vytvořil Blackburnpugh8780 (diskuse | příspěvky) (Založena nová stránka s textem „aureus infections, although further investigation of the effect at the tissue level is required.OBJECTIVE. The purpose of this study was to analyze the tim…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

aureus infections, although further investigation of the effect at the tissue level is required.OBJECTIVE. The purpose of this study was to analyze the timing of major bleeding complications after renal transplant biopsy in the context of a standardized 1-hour postprocedure observation protocol. MATERIALS AND METHODS. We retrospectively reviewed the electronic medical records for consecutive patients who underwent ultrasound-guided renal transplant biopsies between January 1, 2012, and December 31, 2017, and were observed according to a newly implemented 1-hour postprocedure observation protocol. The development of a major bleeding complication (Common Terminology Criteria for Adverse Events class 3 or higher) was recorded along with all available details regarding the time course of patient symptoms and presentation. Complications were grouped into one of four categories according to onset time after biopsy 2 hours or less (timing category 1), more than 2 hours but 4 hours or less (timing category 2), more than 4 hours but 8 hours or less (timing category 3), and more than 8 hours (timing category 4). re recovery period can be safely used after renal transplant biopsy.OBJECTIVE. The aim of this phantom study was to determine whether low-dose CT of the pelvis can be performed using a dose similar to that used in a standard radio-graphic examination and to ascertain whether CT, with its better delineation of complex structures, has greater clinical value than radiography and therefore will result in improved patient care. Special consideration was given to CT performed using the tin filtration technique. MATERIALS AND METHODS. For dose comparison, an anthropomorphic phantom with 20 thermoluminescent dosimeters, two different CT scanners, and three conventional radiography devices were used. Seven CT protocols (including tin filtration) and four different radiographic examinations were performed. Dose calculations, objective and subjective evaluations of image quality, and figure-of-merit calculations were compared among the techniques. Furthermore, the images obtained were evaluated in a clinical context. Intraclass correlation was determined for the subjective results. RESULTS. The dose values of the tested low-dose CT protocols, in particular those using the tin filtration technique, corresponded to or were only slightly higher than the dose values of conventional pelvic radiographic images obtained in three views. Low-dose CT examinations were rated sufficient for consolidation control and had an informative value that was significantly higher than that of conventional radiography. Tin filtering showed the best results for low-dose CT in terms of combining dose and clinically relevant image quality. CONCLUSION. In this phantom study, low-dose CT was superior to radiography for visualizing and evaluating the dorsal pelvic ring, with only marginally higher radiation exposure occurring when the latest-generation CT systems were used. Tin filtration can improve image quality, create further dose reductions, or provide both benefits.OBJECTIVE. Thromboangiitis obliterans (TAO) is an occlusive inflammatory disease affecting small- and medium-sized vessels that causes decrease in life quality and eventually limb loss. The only proven treatment method is smoking cessation, but it may be insufficient for limb salvage in patients with critical limb ischemia. In this single-center retrospective study, the feasibility and efficiency of endovascular treatment in TAO were evaluated. MATERIALS AND METHODS. After approval of the local institutional review board, 41 patients who underwent endovascular treatment of TAO between January 2014 and June 2019 were evaluated retrospectively. Technical success and procedure-related complications were recorded. Decrease in Rutherford classification score, relief of pain, and wound healing were evaluated to determine clinical success. Primary patency, limb salvage rate, and amputation-free survival were also evaluated. RESULTS. A total of 45 limbs were treated during the study period. Technical success was achieved in 82.2% of procedures. Mean follow-up was 29.8 months. Clinical improvement was achieved in 35 limbs. Three patients underwent major amputation and 12 patients underwent minor amputation. Amputation-free survival and limb salvage were both 93.3% at both 1 and 2 years. Reintervention was performed in 14 patients because of occlusion and clinical relapsing of the symptoms. CONCLUSION. Endovascular treatment of TAO is feasible, has a potential to prevent limb amputation in patients with critical limb ischemia, and has acceptable technical success and limb salvage rates. Because there is no consensus in treatment of TAO, prospective comparative studies are needed to determine the effectiveness of an endovascular approach.OBJECTIVE. Metal-on-metal hip arthroplasty has been shown to result in soft-tissue complications in some patients, making revision surgery necessary. CUDC101 Imaging is critical in the detection and surveillance of soft-tissue complications, which are collectively termed adverse reaction to metal debris (ARMD) and adverse local tissue reaction. Studies have investigated the use of ultrasound, MRI, and CT for detecting ARMD, and each modality has advantages and disadvantages. This article provides evidence-based recommendations for imaging surveillance of ARMD. CONCLUSION. Compared with ultrasound, MRI has been found to be a better imaging modality for surveillance of ARMD. In addition, MRI is not operator dependent, allows visualization of soft-tissue details, and allows more consistent measurement of fluid collections on follow-up examinations. Limitations of ultrasound include operator skill, the inability to visualize osseous structures, and the challenge of visualizing posterior soft tissues for synovitis and fluid collections in larger patients. Finally, CT is only useful for focused evaluation of osteolysis or periprosthetic fracture.OBJECTIVE. The purpose of this article is to review important imaging and clinical features to help elucidate causes of lymphadenopathy in patients with HIV infection. CONCLUSION. HIV lymphadenopathy has various causes generally categorized as inflammatory or reactive, such as immune reconstitution syndrome; infectious, such as tuberculous and nontuberculous mycobacterial infections and HIV infection itself; and neoplastic, such as lymphoma, Kaposi sarcoma, and Castleman disease. It is important to consider patients' demographic characteristics, clinical presentations, CD4 lymphocyte counts, and radiologic features to identify likely causes of lymphadenopathy.

Autoři článku: Blackburnpugh8780 (Whalen Singer)