Steffensencurran9493

Z Iurium Wiki

Verze z 25. 8. 2024, 01:15, kterou vytvořil Steffensencurran9493 (diskuse | příspěvky) (Založena nová stránka s textem „The aim of research was to evaluate the maternal serum concentration of selected endogenous steroid hormones during spontaneous parturition at term and to…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

The aim of research was to evaluate the maternal serum concentration of selected endogenous steroid hormones during spontaneous parturition at term and to determinate their association with the need for oxytocin augmentation.

Blood of 108 healthy pregnant women whose parturition started with the regular spontaneous uterine contractions was drawn at the beginning of the labor. Liquid chromatography coupled to the tandem mass spectrometry device was utilized for measurement of sex hormone binding globulin, aldosterone, androstenedione, cortisol, cortisone, corticosterone, dehydroepiandrosterone, dehydroepiandrosteron sulphate, 17-hydroxyprogesterone, progesterone, and testosterone. Mann-Whitney U test, chi-square test, univariate and multivariate logistic regression, and receiver operating characteristic (ROC) analysis were used for the data analysis.

Reference ranges of the selected hormones assessed by liquid chromatography coupled to the tandem mass spectrometry in maternal serum were established. State parturition.

This research provided reference ranges for the selected maternal serum steroid hormones at the beginning of parturition. Association of corticosterone, dehydroepiandrosterone, and androstenedione with the need for the oxytocin infusion usage has been established. Dehydroepiandrosterone could be potential predictor of oxytocin infusion augmentation for progression of the parturition.

Several questionnaires have been developed for screening cannabis use disorder in clinical populations, but very few studies have compared the screening abilities of the different instruments. Here, we aimed to confirm the psychometric properties of a French version of the Cannabis Use Disorder Identification Test-Revised (CUDIT-R), and to compare its screening abilities with those of the Cannabis Abuse Screening Test (CAST), in subjects consulting in mental health settings.

Two hundred and thirteen cannabis smokers who sought treatment for any type of mental disorder, recruited in four French centres, completed the French CUDIT-R (CUDIT-R-Fr) and the full version of the CAST, and were assessed for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria of cannabis use disorder by an addiction specialist. They were retested with the CUDIT-R-Fr after approximately a week. The factorial construct validity, internal consistency and test-retest reliability of the CUDIT-R-Fr were assessed. The compared sensitivity and specificity of the CAST and CUDIT-R-Fr were explored, using the clinician assessment as the reference.

The French CUDIT-R showed a good internal consistency (Cronbach's alpha = 0.89) and an excellent test-retest reliability (ρ = 0.97). The sensitivity and specificity for screening cannabis use disorder were 0.81 and 0.77 for the CUDIT-R, and 0.92 and 0.63 for the CAST, respectively.

Based on the recommended cut-offs, the CAST appeared more sensitive, while the CUDIT-R was more specific, for screening cannabis use disorder in a population of cannabis users with heterogeneous types of mental health disorders.

Based on the recommended cut-offs, the CAST appeared more sensitive, while the CUDIT-R was more specific, for screening cannabis use disorder in a population of cannabis users with heterogeneous types of mental health disorders.

The aim of this study was to determine the level of glass particle contamination from medical ampoules during breakage in nursing practice and their removal by filtration.

Glass medical ampoules were broken-open as instructed and contamination was assessed microscopically.

Three types of medial ampoules (A, B, C) were used. Dispensation of contents was carried out using 21 or 22G needles, with and without syringe-filters. Particles were determined by light microscopy. This study was conducted between April 2018 and January 2020.

Glass particles of 0.94-90.70µm were detected in 94% of all samples. There were 48, 162 and 201 glass particles in groups, A, B and C, respectively. Filtration had no effect in group A but was effective up to 85% in the other groups.

This study confirms that ampoule contents are contaminated with glass particles during the opening procedure, which varies with make and content. Syringe-filter use can be up to 85% effective in their removal.

Use of syringe-filter can decrease glass particle contamination up to 85%. Innovative nursing studies are needed to minimize or completely avoid particule contamination.

Use of syringe-filter can decrease glass particle contamination up to 85%. Innovative nursing studies are needed to minimize or completely avoid particule contamination.

Query a single institution computed tomography (CT) database to assess the prevalence of aortic arch anomalies in general adult population and their potential association with thoracic aortopathies.

CT chest scan reports of patients aged 50-85 years old performed for any indication at a single health system between 2013 and 2016 were included in the analysis. Characteristics of patients with and without aortic arch anomalies were compared by t test and Fisher exact tests. check details Logistic regression analysis was performed to assess for independent risk factors of thoracic aortic aneurysm (TAA).

Of 21,336 CT scans, 603 (2.8%) described arch anomalies. Bovine arch (n = 354, 58.7%) was the most common diagnosis. Patients with arch anomalies were more likely to be female (p < .001), non-Caucasian(p < .001), and hypertensive (p < .001). Prevalence of TAA in arch anomalies group was 10.8% (n = 65) compared to 4.1% (n = 844) in the nonarch anomaly cohort (p < .001). The highest prevalence of thoracic aneurysm was associated with right-sided arch combined with aberrant left subclavian configuration (33%), followed by bovine arch (13%), and aberrant right subclavian artery (8.2%). On binary logistic regression, arch anomaly (OR = 2.85 [2.16-3.75]), aortic valve pathology (OR 2.93 [2.31-3.73]), male sex (OR 2.38 [2.01-2.80]), and hypertension (OR 1.47 [1.25-1.73]) were significantly associated with increased risk of thoracic aneurysm disease.

Reported prevalence of aortic arch anomalies by CT imaging in the older adult population is approximately 3%, with high association of TAA (OR = 2.85) incidence in this subgroup. This may warrant a more tailored surveillance strategy for aneurysm disease in this subpopulation.

Reported prevalence of aortic arch anomalies by CT imaging in the older adult population is approximately 3%, with high association of TAA (OR = 2.85) incidence in this subgroup. This may warrant a more tailored surveillance strategy for aneurysm disease in this subpopulation.

Catheter ablation is highly effective for atrioventricular nodal re-entrant tachycardia (AVNRT). Generally junctional rhythm (JR) is an accepted requirement for successful ablation however there is a lack of detailed prospective studies to determine the characteristics of JR and the impact on slow pathway conduction.

Multicentre prospective observational study evaluating the impact of individual radiofrequency (RF) applications in typical AVNRT (slow/fast). Characteristics of JR during ablation were documented and detailed testing was performed after every RF application to determine outcome. Procedural success was defined as ≤1 AV nodal echo.

Sixty-seven patients were included (mean age 53 ± 18years, 57% female and a history of SVT 2.9 ± 4.7 years). RF (50w, 60°) ablation for AVNRT was applied in 301 locations with JR in 178 (59%). Successful slow pathway modification was achieved in 66 (99%) patients with slow pathway block in 30 (46%). Success was associated with JR in all patients. Success was achieould not be intentionally targeted.18F-Sodium Fluoride (18F-NaF) positron emission tomography (PET) provides high resolution functional information about bone activity and can be fused with CT images to improve three-dimensional localization and characterization of lesions. This prospective, observational study assessed 18F-NaF PET-CT for imaging of canine elbows, compared PET with CT findings, and assessed correlation with lameness. Twelve patients with elbow pain were included. Cases included primarily young, large breed dogs. A three-level clinical lameness score was assigned to each forelimb. All dogs had bilateral elbow joints imaged with CT and PET under general anesthesia, approximately 1.5 h after intravenous injection of 3 MBq/kg of 18F-NaF. Imaging findings were independently reviewed by two radiologists using a three-level scoring scheme over nine anatomical regions in the elbow. PET imaging identified areas of bone activity where minimal change was identified on CT. PET imaging also demonstrated absence of uptake in areas where modeling was present on CT. A stronger correlation was observed between clinical grades and PET scores (r2 = 0.38, P = .001) than between clinical grades and CT scores (r2 = 0.17, P = .048). The total PET scores were significantly different for each clinical grade (P = .013) but total CT scores did not differ (P = .139). This exploratory study suggests that PET improves the ability to detect lesions and to determine the clinical significance of CT findings in dogs with elbow pain.Hepatic fibrosis is a wound healing response that results in excessive extracellular matrix (ECM) accumulation in response to chronic hepatic injury. Signal transducer and activator of transcription 3 (STAT3) is an important transcription factor associated with the pathogenesis of liver fibrosis. Though a promising potential therapeutic target, there are no specific drug candidates for STAT3. Exosomes are extracellular vesicles generated by all cell types with a capacity to efficiently enter cells across different biological barriers. Here, we utilize exosomes as delivery conduit to specifically target STAT3 in liver fibrosis. Exosomes derived from clinical grade fibroblast-like mesenchymal stem cells (MSCs) were engineered to carry siRNA or antisense oligonucleotide (ASO) targeting STAT3 (iExosiRNA-STAT3 or iExomASO-STAT3 ). Compared to scrambled siRNA control, siRNA-STAT3, or ASO-STAT3, iExosiRNA-STAT3 or iExomASO-STAT3 showed enhanced STAT3 targeting efficiency. iExosiRNA-STAT3 or iExomASO-STAT3 treatments suppressed STAT3 levels and ECM deposition in established liver fibrosis in mice, and significantly improved liver function. iExomASO-Stat3 restored liver function more efficiently when compared to iExosiRNA-STAT3 . Our results identify a novel anti-fibrotic approach for direct targeting of STAT3 with exosomes with immediate translational potential.Fluorinated heterocycles have attracted much attention in the pharmaceutical and agrochemical industries. Many strategies have already been developed to achieve the synthesis of fluorinated heterocycles. Formidable challenges remain, however, in the synthesis of fluorinated isocoumarin derivatives that are among the most alluring structural motifs. Herein, the indium-catalyzed C-F bond transformation of 2-(2,2-difluorovinyl) benzoates is reported, which are readily accessible compounds, to give a diverse array of fluorinated isocoumarins. The present reaction proceeds smoothly using inexpensive reagents a catalytic amount of indium salt in the presence of zinc salt. A theoretical calculation of potential energy profiles showed that the reaction consists of oxymetalation with the elimination of alkyl halide and the β-fluorine elimination.

Autoři článku: Steffensencurran9493 (Bengtsson Berthelsen)