Verze z 16. 8. 2024, 15:46, kterou vytvořil Hebertrush9264 (diskuse | příspěvky) (Založena nová stránka s textem „A nanocrystalline microstructure with the grain size of 10-20 nm was developed in the whole layer, irrespective of the chemical composition. Transmission e…“)
(rozdíl) ← Starší verze | zobrazit aktuální verzi (rozdíl) | Novější verze → (rozdíl)

A nanocrystalline microstructure with the grain size of 10-20 nm was developed in the whole layer, irrespective of the chemical composition. Transmission electron microscopy indicated a columnar growth of the film during PVD. The density of as-grown dislocations and twin faults was very high, as obtained by synchrotron X-ray diffraction peak profile analysis. The nanohardness and the elastic modulus were determined by indentation for the different chemical compositions on the combinatorial PVD film. This study is the continuation of a former research published recently in Nagy et al., Materials 14 (2021) 3357. In the previous work, only the fcc part of the sample was investigated. In the present paper, the study was extended to the bcc, hcp and multiphase regions.To further explore the potential of Zr-based alloys as a biomaterial that will not interfere with magnetic resonance imaging (MRI), the microstructural characteristics of Zr-xat.% Nb alloys (10 ≤ x ≤ 18), particularly the athermal ω phase and lattice modulation, were investigated by conducting electrical resistivity and magnetic susceptibility measurements and transmission electron microscopy observations. The 10 Nb alloy and 12 Nb alloys had a positive temperature coefficient of electrical resistivity. The athermal ω phase existed in 10 Nb and 12 Nb alloys at room temperature. Alternatively, the 14 Nb and 18 Nb alloys had an anomalous negative temperature coefficient of the resistivity. The selected area diffraction pattern of the 14 Nb alloy revealed the co-occurrence of ω phase diffraction and diffuse satellites. These diffuse satellites were represented by gβ + q when the zone axis was [001] or [113], but not [110]. These results imply that these diffuse satellites appeared because the transverse waves consistent with the propagation and displacement vectors were q = <ζ ζ¯ 0>* for the ζ~1/2 and <110> directions. It is possible that the resistivity anomaly was caused by the formation of the athermal ω phase and transverse wave. Moreover, control of the athermal ω-phase transformation and occurrence of lattice modulation led to reduced magnetic susceptibility, superior deformation properties, and a low Young's modulus in the Zr-Nb alloys. Thus, Zr-Nb alloys are promising MRI-compatible metallic biomaterials.DM has a high prevalence worldwide and exerts a negative influence on bone repair around dental implants. Modifications of the microgeometry of implants have been related to positive results in bone repair. this website This study assessed, for the first time, the influence of an implant with modified macrodesign based on the presence of a healing chamber in the pattern of peri-implant repair under diabetic conditions. Thirty Wistar rats were assigned to receive one titanium implant in each tibia (Control Implant (conventional macrogeometry) or Test Implant (modified macrogeometry)) according to the following groups Non-DM + Control Implant; Non-DM + Test Implant; DM + Control Implant; DM + Test Implant. One month from the surgeries, the implants were removed for counter-torque, and the bone tissue surrounding the implants was stored for the mRNA quantification of bone-related markers. Implants located on DM animals presented lower counter-torque values in comparison with Non-DM ones, independently of macrodesign (p < 0.05). Besides, higher biomechanical retention levels were observed in implants with modified macrogeometry than in the controls in both Non-DM and DM groups (p < 0.05). Moreover, the modified macrogeometry upregulated OPN mRNA in comparison with the control group in Non-DM and DM rats (p < 0.05). Peri-implant bone repair may profit from the use of implants with modified macrogeometry in the presence of diabetes mellitus, as they offer higher biomechanical retention and positive modulation of important bone markers in peri-implant bone tissue.The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures' diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.A high protection level without an excessive weight is a basic assumption in the design of modern armors and protection systems. Optimizing armors is a task of development of the utmost importance, and is the subject of the work contained within this article. Optimization of ballistic inserts was carried out using multicriterial analysis (MCA), which enables the selection of the optimal composition, taking into account properties such as ballistic resistance, physicomechanical, and/or functional properties. For this purpose, various types of composite systems were produced and tested in terms of their fragment-resistant properties according to STANAG 2920 and the composite areal density of different ballistic inserts Soft inserts made of Twaron® para-aramid sheets, hard ballistic inserts made of multilayer hot-pressed preimpregnated sheets, and hybrid hard ballistic inserts prepared on the basis of multilayer hot-pressed preimpregnated sheets and ceramics. The application of MCA and performance of experimental fragment resistance tests for a wide spectrum of para-aramid inserts are part of the novelty of this work. The obtained test results showed that depending on the composition of the composite system, we could obtain a wide range of fragmentation resistance in the range of 300 to >1800 m/s, which depended on the areal density and type of composite system used. The results also confirmed that MCA is a good computational tool to select the optimal design of para-aramid ballistic inserts.Polydimethylsiloxane (PDMS), a silicone elastomer, is increasingly being used in health and biomedical fields due to its excellent optical and mechanical properties. Its biocompatibility and resistance to biodegradation led to various applications (e.g., lung on a chip replicating blood flow, medical interventions, and diagnostics). The many advantages of PDMS are, however, partially offset by its inherent hydrophobicity, which makes it unsuitable for applications needing wetting, thus requiring the hydrophilization of its surface by exposure to UV or O2 plasma. Yet, the elastomeric state of PDMS translates in a slow, hours to days, process of reducing its surface hydrophilicity-a process denominated as hydrophobic recovery. Using Fourier transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM), the present study details the dynamics of hydrophobic recovery of PDMS, on flat bare surfaces and on surfaces embedded with hydrophilic beads. It was found that a thin, stiff, hydrophilic, silica film y considering the emergence of new surgical procedures using elastomers, the impact of hydrophobic recovery on the surface of PDMS warrants more comprehensive studies.New three-ring ester/azomethine homologues series, (E)-4-((4-hydroxybenzylidene)amino)phenyl 4-(alkoxy)benzoate In, were prepared and their properties were investigated experimentally and theoretically. FT-IR, NMR, and elemental analyses were used to confirm the chemical structures of the synthesized compounds. The mesomorphic activities of the planned homologues were evaluated using differential scanning calorimetry (DSC) and polarized optical microscopy. All of the homologous examined were found to have non-mesomorphic properties. Theoretical calculations using the density functional theory (DFT) were used to validate the experimental data and determine the most stable conformation of the synthesized compounds. All calculated conformers' thermal properties, dipole moments, and polarizability were discussed. The results show that the terminal alkoxy chain length affects the thermal parameters of the conformers. The correlations between these parameters' values and the conformer type were demonstrated. The base component was expected to be in two conformers according to the orientation of the N atom of imine-linkage. DFT calculations revealed the more probable of the two possible conformers, and the incorporation of the alkoxy terminal chain in one position affect its geometrical and mesomerphic characteristics.The morphology and intermolecular interaction are two of the most important factors in the design of highly efficient dye adsorbent in the industry. Millimeter-sized, bead-type, bio-based lignin/chitosan (Lig/CS) adsorbent was designed for the removal of Congo red (CR), based on the electrostatic attraction, π-π stacking, and hydrogen bonding, which were synthesized through the emulsification of the chitosan/lignin mixture followed by chemical cross-linking. The effects of the lignin/chitosan mass ratio, initial pH, temperature, concentration, and contact time on the adsorption were thoroughly investigated. The highest adsorption capacity (173 mg/g) was obtained for the 20 wt% Lig/CS beads, with a removal rate of 86.5%. To investigate the adsorption mechanism and recyclability, an evaluation of the kinetic model and an adsorption/desorption experiment were conducted. The adsorption of CR on Lig/CS beads followed the type 1 pseudo-second-order model, and the removal rate for CR was still above 90% at five cycles.This study presents an experimental investigation on the low-velocity impact response of three-dimensional integrated woven spacer sandwich composites made of high-performance glass fiber reinforced fabric and epoxy resin. 3D integrated woven spacer sandwich composites with five different specifications were produced using a hand lay-up process and tested under low-velocity impact with energies of 5 J, 10 J, and 15 J. The results revealed that the core pile's heights and diverse impact energies significantly affect the stiffness and energy absorption capacity. There is no significant influence of face sheet thickness on impact response. Moreover, the damage morphologies of 3D integrated woven spacer sandwich composites under different impact energies were analyzed by simple visualization of the specimen. Different damage and failure mechanisms were observed, including barely visible damage, visible damage, and clearly visible damage. Moreover, it was noticed that the damage of 3D integrated woven spacer sandwich composites samples only constraints to the impacted area and does not affect the integrity of the samples.

Autoři článku: Hebertrush9264 (Gissel Covington)